78 research outputs found
Recommended from our members
SCB thermite igniter studies
The authors report on recent studies comparing the ignition threshold of temperature cycled, SCB thermite devices with units that were not submitted to temperature cycling. Aluminum/copper-oxide thermite was pressed into units at two densities, 45% of theoretical maximum density (TMD) or 47% of TMD. Half of each of the density sets underwent three thermal cycles; each cycle consisted of 2 hours at 74 C and 2 hours at {minus}54 C, with a 5 minute maximum transfer time between temperatures. The temperature cycled units were brought to ambient temperature before the threshold testing. Both the density and the thermal cycling affected the all-fire voltage. Using a 5.34 {micro}F CDU (capacitor discharge unit) firing set, the all-fire voltage for the units that were not temperature cycled increased with density from 32.99 V (45% TMD) to 39.32 V (47% TMD). The all-fire voltages for the thermally cycled units were 34.42 V (45% TMD) and 58.1 V (47% TMD). They also report on no-fire levels at ambient temperature for two component designs; the 5 minute no-fire levels were greater than 1.2 A. Units were also subjected to tests in which 1 W of RF power was injected into the bridges at 10 MHz for 5 minutes. The units survived and fired normally afterwards. Finally, units were subjected to pin-to-pin electrostatic discharge (ESD) tests. None of the units fired upon application of the ESD pulse, and all of the tested units fired normally afterwards
Recommended from our members
Semiconductor bridge, SCB, ignition studies of Al/CuO thermite
The authors briefly summarize semiconductor bridge operation and review their ignition studies of Al/CuO thermite as a function of the capacitor discharge unit (CDU) firing set capacitance, charge holder material and morphology of the CuO. Ignition thresholds were obtained using a brass charge holder and a non-conducting fiber-glass-epoxy composite material, G10. At - 18 C and a charge voltage of 50V, the capacitance thresholds were 30.1 {mu}F and 2.0 {mu}F respectively. They also present new data on electrostatic discharge (ESD) and radio frequency (RF) vulnerability tests
Quantitative measurement of combustion gases in harsh environments using NDIR spectroscopy
The global climate change calls for more environmentally friendly use of
energy and has led to stricter limits and regulations for the emissions of
various greenhouse gases. Consequently, there is nowadays an increasing need
for the detection of exhaust and natural gases. This need leads to an
ever-growing market for gas sensors, which, at the moment, is dominated by
chemical sensors. Yet, the increasing demands to also measure under harsh
environmental conditions pave the way for non-invasive measurements and thus
optical detection techniques. Here, we present the development of two optical
detection systems using non-dispersive infrared absorption spectroscopy
(NDIR). One system is intended for civilian use, capable of detecting both CO
as well as CO2 in the range of 4–5 µm. Furthermore,
restrictions regarding size and economic viability are put on this sensor so
it can compete with existing sensors. For CO2, an estimated
resolution of 444 ppm is achieved, which is competitive with established
sensors on the market. For CO an estimated resolution of 1401 ppm was
achieved, rendering it necessary to improve this sensor to be competitive
with other available sensors. The second system is used in an exhaust system
and is capable of detecting CO2 at 3.2 µm facing
cross-sensitivity with H2O. A data analysis method is described to
separate the CO2 and H2O signals, revealing a time resolution
of 33 µs.</p
Probing a Complex of Cytochromecand Cardiolipin by Magnetic Circular Dichroism Spectroscopy: Implications for the Initial Events in Apoptosis
Oxidation of cardiolipin (CL) by its complex with cytochrome c (cyt c) plays a crucial role in triggering apoptosis. Through a combination of magnetic circular dichroism spectroscopy and potentiometric titrations, we show that both the ferric and ferrous forms of the heme group of a CL:cyt c complex exist as multiple conformers at a physiologically relevant pH of 7.4. For the ferric state, these conformers are His/Lys- and His/OH–-ligated. The ferrous state is predominantly high-spin and, most likely, His/–. Interconversion of the ferric and ferrous conformers is described by a single midpoint potential of -80 ± 9 mV vs SHE. These results suggest that CL oxidation in mitochondria could occur by the reaction of molecular oxygen with the ferrous CL:cyt c complex in addition to the well-described reaction of peroxides with the ferric form
Decision aids for respite service choices by carers of people with dementia: development and pilot RCT
<p>Abstract</p> <p>Background</p> <p>Decision aids are often used to assist individuals confronted with a diagnosis of a serious illness to make decisions about treatment options. However, they are rarely utilised to help those with chronic or age related conditions to make decisions about care services. Decision aids should also be useful for carers of people with decreased decisional capacity. These carers' choices must balance health outcomes for themselves and for salient others with relational and value-based concerns, while relying on information from health professionals. This paper reports on a study that both developed and pilot tested a decision aid aimed at assisting carers to make evaluative judgements of community services, particularly respite care.</p> <p>Methods</p> <p>A mixed method sequential study, involving qualitative development and a pilot randomised controlled trial, was conducted in Tasmania, Australia. We undertook 13 semi-structured interviews and three focus groups to inform the development of the decision aid. For the randomised control trial we randomly assigned 31 carers of people with dementia to either receive the service decision aid at the start or end of the study. The primary outcome was measured by comparing the difference in carer burden between the two groups three months after the intervention group received the decision aid. Pilot data was collected from carers using interviewer-administered questionnaires at the commencement of the project, two weeks and 12 weeks later.</p> <p>Results</p> <p>The qualitative data strongly suggest that the intervention provides carers with needed decision support. Most carers felt that the decision aid was useful. The trial data demonstrated that, using the mean change between baseline and three month follow-up, the intervention group had less increase in burden, a decrease in decisional conflict and increased knowledge compared to control group participants.</p> <p>Conclusions</p> <p>While these results must be interpreted with caution due to the small sample size, all intervention results trend in a direction that is beneficial for carers and their decisional ability. Mixed method data suggest the decision aid provides decisional support that carers do not otherwise receive. Decision aids may prove useful in a community health services context.</p> <p>Trial registration number</p> <p>ISRCTN: <a href="http://www.controlled-trials.com/ISRCTN32163031">ISRCTN32163031</a></p
A qualitative study of professional and client perspectives on information flows and decision aid use
<p>Abstract</p> <p>Background</p> <p>This paper explores the meanings given by a diverse range of stakeholders to a decision aid aimed at helping carers of people in early to moderate stages of dementia (PWD) to select community based respite services. Decision aids aim to empower clients to share decision making with health professionals. However, the match between health professionals' perspectives on decision support needs and their clients' perspective is an important and often unstudied aspect of decision aid use.</p> <p>Methods</p> <p>A secondary analysis was undertaken of qualitative data collected as part of a larger study. The data included twelve interviews with carers of people with dementia, three interviews with expert advisors, and three focus groups with health professionals. A theoretical analysis was conducted, drawing on theories of 'positioning' and professional identity.</p> <p>Results</p> <p>Health professionals are seen to hold varying attitudes and beliefs about carers' decision support needs, and these appeared to be grounded in the professional identity of each group. These attitudes and beliefs shaped their attitudes towards decision aids, the information they believed should be offered to dementia carers, and the timing of its offering. Some groups understood carers as needing to be protected from realistic information and consequently saw a need to filter information to carer clients.</p> <p>Conclusion</p> <p>Health professionals' beliefs may cause them to restrict information flows, which can limit carers' ability to make decisions, and limit health services' ability to improve partnering and shared decision making. In an era where information is freely available to those with the resources to access it, we question whether health professionals should filter information.</p
SERS spectroscopic evidence for the integrity of surface-deposited self-assembled coordination cages
A series of self-assembled coordination cages [pd(4)L(8)(n)] based on a phenothiazine backbone has been investigated by means of Raman spectroscopy in solution and by Surface Enhanced Raman Scattering (SERS) on a nanostructured Au surface. The experiments demonstrate that the cages can be clearly distinguished from their constituting ligands by their Raman spectroscopic signatures. Furthermore, the structural integrity of the interpenetrated coordination cages upon deposition on the Au surface was demonstrated for the first time. The signal assignment of the experimental vibrational spectra was supported by Density Functional Theory (DFT) calculations on suitable molecular models.Evonik Foundation; DFG [CL 489/2-1]; Fonds der Chemischen Industri
- …