389 research outputs found

    DFT Calculations as a Tool to Analyse Quadrupole Splittings of Spin Crossover Fe(II) complexes

    Full text link
    Density functional methods have been applied to calculate the quadrupole splitting of a series of iron(II) spin crossover complexes. Experimental and calculated values are in reasonable agreement. In one case spin-orbit coupling is necessary to explain the very small quadrupole splitting value of 0.77 mm/s at 293 K for a high-spin isomer

    Virtual 3D planning of tracheostomy placement and clinical applicability of 3D cannula design:A three-step study

    Get PDF
    AIM: We aimed to investigate the potential of 3D virtual planning of tracheostomy tube placement and 3D cannula design to prevent tracheostomy complications due to inadequate cannula position. MATERIALS AND METHODS: 3D models of commercially available cannula were positioned in 3D models of the airway. In study (1), a cohort that underwent tracheostomy between 2013 and 2015 was selected (n = 26). The cannula was virtually placed in the airway in the pre-operative CT scan and its position was compared to the cannula position on post-operative CT scans. In study (2), a cohort with neuromuscular disease (n = 14) was analyzed. Virtual cannula placing was performed in CT scans and tested if problems could be anticipated. Finally (3), for a patient with Duchenne muscular dystrophy and complications of conventional tracheostomy cannula, a patient-specific cannula was 3D designed, fabricated, and placed. RESULTS: (1) The 3D planned and post-operative tracheostomy position differed significantly. (2) Three groups of patients were identified: (A) normal anatomy; (B) abnormal anatomy, commercially available cannula fits; and (C) abnormal anatomy, custom-made cannula, may be necessary. (3) The position of the custom-designed cannula was optimal and the trachea healed. CONCLUSIONS: Virtual planning of the tracheostomy did not correlate with actual cannula position. Identifying patients with abnormal airway anatomy in whom commercially available cannula cannot be optimally positioned is advantageous. Patient-specific cannula design based on 3D virtualization of the airway was beneficial in a patient with abnormal airway anatomy

    Dynamics of Metal Centers Monitored by Nuclear Inelastic Scattering

    Full text link
    Nuclear inelastic scattering of synchrotron radiation has been used now since 10 years as a tool for vibrational spectroscopy. This method has turned out especially useful in case of large molecules that contain a M\"ossbauer active metal center. Recent applications to iron-sulfur proteins, to iron(II) spin crossover complexes and to tin-DNA complexes are discussed. Special emphasis is given to the combination of nuclear inelastic scattering and density functional calculations

    Waveguide structures for efficient evanescent field coupling to zero mode waveguides

    Get PDF
    The use of waveguide structures is examined to improve the efficiency of evanescent field coupling into zero-mode waveguides. Model calculations show that waveguide excitation using diffractive structures, increases the magnitude of the evanescent electric field by an order of magnitude compared to far field excitation of the evanescent field. A more efficient excitation of fluorescent markers used in e.g. sequencing instrumentation ultimately enables real-time single molecule detection using laser systems with moderate output power

    First-Principles Calculations of Hyperfine Interactions in La_2CuO_4

    Full text link
    We present the results of first-principles cluster calculations of the electronic structure of La_2CuO_4. Several clusters containing up to nine copper atoms embedded in a background potential were investigated. Spin-polarized calculations were performed both at the Hartree-Fock level and with density functional methods with generalized gradient corrections to the local density approximation. The distinct results for the electronic structure obtained with these two methods are discussed. The dependence of the electric-field gradients at the Cu and the O sites on the cluster size is studied and the results are compared to experiments. The magnetic hyperfine coupling parameters are carefully examined. Special attention is given to a quantitative determination of on-site and transferred hyperfine fields. We provide a detailed analysis that compares the hyperfine fields obtained for various cluster sizes with results from additional calculations of spin states with different multiplicities. From this we conclude that hyperfine couplings are mainly transferred from nearest neighbor Cu^{2+} ions and that contributions from further distant neighbors are marginal. The mechanisms giving rise to transfer of spin density are worked out. Assuming conventional values for the spin-orbit coupling, the total calculated hyperfine interaction parameters are compared to informations from experiments.Comment: 23 pages, 9 figure

    Neonatal jaundice in the healthy newborn:Are the guidelines conclusive?

    Get PDF
    Three cases are reported of term neonates with high serum total bilirubin levels without evident signs indicating hemolytic or other underlying disease. The three patients were treated with phototherapy and/or exchange transfusion. It is discussed that the current consensus guidelines are inconclusive with respect to 'success of phototherapy' and 'signs of underlying disease'. Recommendations are made to improve the practice guidelines.</p

    Evaporation and explosion of liquid drops on a heated surface

    Full text link
    The literature pertinent to various aspects of drop evaporation on a heated surface is reviewed. Both the laser shadowgraphic and direct photographic methods are employed to study thermal stability and flow structures in evaporating drops in all heating regimes. It is revealed that four flow regions exist in stable and unstable type drops at low liquid-film type vaporization regime. As the surface temperature is raised, the flow regions reduce to two. In the nucleate-boiling type vaporization regime, the interfacial flow structure changes due to a reduction in the Marangoni number as well as the dielectric constant of the liquid. An evidence of bubble growth in the drops is disclosed. The micro explosion of drops is found to occur in the transition-boiling type heating range. No drop explosion takes place in the spheriodal vaporization regime except when the drop rolls on to a microscratch on the heating surface. It is concluded that the mechanisms for triggering drop explosion include the spontaneous nucleation and growth phenomena and the destabilization of film boiling.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/47061/1/348_2004_Article_BF00266263.pd

    Pharmacokinetics of gemcitabine in non-small-cell lung cancer patients: impact of the 79A>C cytidine deaminase polymorphism

    Get PDF
    To study the impact of the 79A > C polymorphism in the cytidine deaminase (CDA) gene on the pharmacokinetics of gemcitabine and its metabolite 2',2'-difluorodeoxyuridine (dFdU) in non-small-cell lung cancer (NSCLC) patients. Patients (n = 20) received gemcitabine 1,125 mg/m(2) as a 30 min i.v. infusion as part of treatment for NSCLC. Plasma samples were collected during 0-6 h after gemcitabine administration. Gemcitabine and dFdU were quantified by high performance liquid chromatography with ultraviolet detection. The CDA 79A > C genotype was determined with PCR and DNA sequencing. Gemcitabine was rapidly cleared from plasma and undetectable after 3 h. The allele frequency of the 79A > C polymorphism was 0.40. Diplotypes were distributed as A/A n = 8, A/C n = 8 ,and C/C n = 4. No significant differences were found between the different CDA genotypes and gemcitabine or dFdU AUC, clearance, or half-life. The 79A > C polymorphism in the CDA gene does not have a major consistent and signficant impact on gemcitabine pharmacokinetics

    Experimental and theoretical investigation on the misalignment tolerance of a micron-sized solid immersion lens tolerance of a micron-sized solid immersion lens

    Get PDF
    We report an experimental and theoretical study on the alignment error tolerance of a 2 µm-size solid immersion lens (SIL) illuminated by different types of focused spots. Tightly confined focal spots are of great interest for improving the performance of many optical systems, so that a study on the alignment tolerance is of interest. In particular, it was found that micro-SILs can be largely misaligned with respect to the optical axis of an objective lens focusing light onto it and yet allow for a reasonably good immersed spot. In fact, a displacement of approximately 400 nm, i.e. one fifth of the lens diameter, is tolerable. The measurements are compared with a rigorous finite element method model for a micro-SIL, showing an excellent agreemen

    Submicron hollow spot generation by solid immersion lens and structured illumination

    Get PDF
    We report on the experimental and numerical demonstration of immersed submicron-size hollow focused spots, generated by structuring the polarization state of an incident light beam impinging on a micro-size solid immersion lens (ÎĽ-SIL) made of SiO2. Such structured focal spots are characterized by a doughnut-shaped intensity distribution, whose central dark region is of great interest for optical trapping of nano-size particles, super-resolution microscopy and lithography. In this work, we have used a high-resolution interference microscopy technique to measure the structured immersed focal spots, whose dimensions were found to be significantly reduced due to the immersion effect of the ÎĽ-SIL. In particular, a reduction of 37% of the dark central region was verified. The measurements were compared with a rigorous finite element method model for the ÎĽ-SIL, revealing excellent agreement between them
    • …
    corecore