42 research outputs found

    Serum screening with Down's syndrome markers to predict pre-eclampsia and small for gestational age: Systematic review and meta-analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Reliable antenatal identification of pre-eclampsia and small for gestational age is crucial to judicious allocation of monitoring resources and use of preventative treatment with the prospect of improving maternal/perinatal outcome. The purpose of this systematic review was to determine the accuracy of five serum analytes used in Down's serum screening for prediction of pre-eclampsia and/or small for gestational age.</p> <p>Methods</p> <p>The data sources included Medline, Embase, Cochrane library, Medion (inception to February 2007), hand searching of relevant journals, reference list checking of included articles, contact with experts. Two reviewers independently selected the articles in which the accuracy of an analyte used in Downs's serum screening before the 25<sup>th </sup>gestational week was associated with the occurrence of pre-eclampsia and/or small for gestational age without language restrictions. Two authors independently extracted data on study characteristics, quality and results.</p> <p>Results</p> <p>Five serum screening markers were evaluated. 44 studies, testing 169,637 pregnant women (4376 pre-eclampsia cases) and 86 studies, testing 382,005 women (20,339 fetal growth restriction cases) met the selection criteria. The results showed low predictive accuracy overall. For pre-eclampsia the best predictor was inhibin A>2.79MoM positive likelihood ratio 19.52 (8.33,45.79) and negative likelihood ratio 0.30 (0.13,0.68) (single study). For small for gestational age it was AFP>2.0MoM to predict birth weight < 10<sup>th </sup>centile with birth < 37 weeks positive likelihood ratio 27.96 (8.02,97.48) and negative likelihood ratio 0.78 (0.55,1.11) (single study). A potential clinical application using aspirin as a treatment is given as an example.</p> <p>There were methodological and reporting limitations in the included studies thus studies were heterogeneous giving pooled results with wide confidence intervals.</p> <p>Conclusion</p> <p>Down's serum screening analytes have low predictive accuracy for pre-eclampsia and small for gestational age. They may be a useful means of risk assessment or of use in prediction when combined with other tests.</p

    Temperature sensitivity of mid-infrared type II "W" interband cascade lasers (ICL) emitting at 4.1μm at room temperature

    No full text
    The thermal properties of 5-stage “W” Interband-Cascade Lasers emitting at 4.1μm at RT are investigated. It is shown that inter-valence band absorption coupled with non-radiative recombination govern their maximum operating temperature

    Multi-species sensing using multi-mode absorption spectroscopy with mid-infrared interband cascade lasers

    Get PDF
    The application of an interband cascade laser, ICL, to multi-mode absorption spectroscopy, MUMAS, in the mid-infrared region is reported. Measurements of individual mode linewidths of the ICL, derived from the pressure dependence of lineshapes in MUMAS signatures of single, isolated, lines in the spectrum of HCl, were found to be in the range 10–80 MHz. Multi-line spectra of methane were recorded using spectrally limited bandwidths, of approximate width 27 cm−1, defined by an interference filter, and consist of approximately 80 modes at spectral locations spanning the 100 cm−1 bandwidth of the ICL output. Calibration of the methane pressures derived from MUMAS data using a capacitance manometer provided measurements with an uncertainty of 1.1 %. Multi-species sensing is demonstrated by the simultaneous detection of methane, acetylene and formaldehyde in a gas mixture. Individual partial pressures of the three gases are derived from best fits of model MUMAS signatures to the data with an experimental error of 10 %. Using an ICL, with an inter-mode interval of ~10 GHz, MUMAS spectra were recorded at pressures in the range 1–10 mbar, and, based on the data, a potential minimum detection limit of the order of 100 ppmv is estimated for MUMAS at atmospheric pressure using an inter-mode interval of 80 GHz

    Multi-species detection using mid-infrared multi-mode absorption spectroscopy, MUMAS

    No full text
    Multi-mode absorption spectroscopy has been used to detect CH4, NH3 and N2O individually or simultaneously in mixtures using multi-mode radiation generated by difference frequency generation at 3.3 μm or inter-band cascade lasers at 3.7 μm. © 2014 OSA

    Multi-species detection using mid-infrared multi-mode absorption spectroscopy, MUMAS

    No full text
    Multi-mode absorption spectroscopy has been used to detect CH4, NH3 and N2O individually or simultaneously in mixtures using multi-mode radiation generated by difference frequency generation at 3.3 μm or inter-band cascade lasers at 3.7 μm. © 2014 OSA
    corecore