216 research outputs found

    Utility-Oriented Placement of Actuator Nodes with a Collaborative Serving Scheme for Facilitated Business and Working Environments

    Get PDF
    Places to be served by cyber-physical systems (CPS) are usually distributed unevenly over the area. Thus, different areas usually have different importance and values of serving. In other words, serving power can be excessive or insufficient in practice. Therefore, actuator nodes (ANs) in CPS should be focused on serving around points of interest (POIs) with considerations of “service utility.” In this paper, a utility-oriented AN placement framework with a collaborative serving scheme is proposed. Through spreading serving duties among correctly located ANs, deployment cost can be reduced, utility of ANs can be fully utilized, and the system longevity can be improved. The problem has been converted into a binary integer linear programming optimization problem. Service fading, 3D placements, multiscenario placements, and fault-tolerant placements have been modeled in the framework. An imitated example of a CPS deployment in a smart laboratory has been used for evaluations.published_or_final_versio

    Fabrication of organic photovoltaic devices by the layer-by-layer polyelectrolyte deposition method

    Get PDF
    Organic photovoltaic cells were fabricated by the layer-by-layer polyelectrolyte deposition process by which the film thickness can be controlled accurately. Ruthenium/rhenium complexes containing poly(p-phenylenevinylene) and sulfonated polyaniline were used in the process. This new method provides flexibility in the fabrication of multilayer polymeric devices with well-defined structure. © 2005 IEEE.published_or_final_versio

    Fabrication of bulk heterojunction photovoltaic devices using sublimable rhenium diimine complexes as photosensitizers

    Get PDF
    A series of chlorotricarbonyl rhenium (I) bis(phenylimino)acenaphthene (Re-DIAN-X) complexes were used as the photosensitizers for photovoltaic cells. Unlike other transition-metal-based photovoltaic sensitizers that can only be prepared by solution method, these complexes are sublimable. Compared to other rhenium diimine complexes based on bipyridine or 1,4-diaza-1,3-butadiene ligands, these complexes have lower band gaps, which can be modified easily by changing the structure of the ligand. It allows the preparation of blend of metal complexes in order to broaden the sensitization region in UV-vis absorption spectrum. One of the complexes also shows bipolar charge transport character with relatively high charge carrier mobilities in the order of 10 -3 cm2V-1s-1. Multilayer heterojunction and bulk heterojunction devices with fullerene as the electron accepting molecule were prepared. For the bulk heterojunction devices, the fill factor and power conversion efficiency under AM 1.5 simulated solar light illumination were 0.51 and 1.29 %, respectively. The effects of changing the Re-DIAN/C60 film thickness, Re-DIAN/C60 ratio and variation of ligand structures in the bulk heterojunction devices were studied. The amount of photosensitizer and electron transport molecules may strongly affect the balance between the photon absorption, exciton formation, dissociation, and charge transport processes. Atomic force microscopic images showed that the complex dispersed evenly with fullerene molecules in solid state.published_or_final_versio

    Fabrication of Photovoltaic Cell from Ruthenium Containing Polymer Using Layer by Layer Polyelectrolytes Adsorption Technique

    Get PDF
    Multilayer photovoltaic devices were fabricated by the sequence adsorption of different polyelectrolytes. A ruthenium terpyridine complex containing poly(p-phenylenevinylene) was used as the polycation layer. This polymer has been shown to exhibit large photo-sensitivity due to the presence of the ruthenium complex, which has relatively long-lived excited state. This polymer absorbs strongly in the visible region at ca. 480-550 nm and it can act as the electron transporter. Sulfonated polyaniline was used as the hole-transporting polyanion layer. The ITO/(polyanion/polycation) n/A1 devices were found to exhibit photovoltaic properties under the illumination of AM1 solar radiation. The short-circuit current I sc, open-circuit voltage V oc, and the fill factor FF were measured to be 14 μA/cm 2, 0.84 V and 0.16 respectively. It was found that the power conversion efficiencies of the devices were dependent on the device thickness. This simple layer-by-layer self-assembly method allowed us to control the devices thickness accurately.published_or_final_versio

    Low-band-gap, sublimable rhenium(I) diimine complex for efficient bulk heterojunction photovoltaic devices

    Get PDF
    The fabrication of efficient bulk heterojunction photovoltaic cells using the chlorotricarbonyl rhenium(I) diimine complex as photosensitizer was discussed. The complex has a lower band gap, which can be adjusted easily by changing the structure of the ligand. The electric properties of the complex were studied using time-of-flight analysis. It was observed that the rhenium complex showed bipolar charge transport character with relatively high electron and hole mobilities.published_or_final_versio

    Coriolus versicolor Yun-Zhi could delay deterioration of patients with advanced non-small cell lung cancer

    Get PDF
    published_or_final_versio

    Efficient bulk heterojunction photovoltaic cells using sublimable transition metal complex as photosensitizers

    Get PDF
    Multilayer bulk heterojunction photovoltaic cells using chlorotricarbonyl rhenium (I) bis(phenylimino)acenaphthene (Re-DIAN) complex as photosensitizer were studied. The complex is sublimable, has lower band gap, good thermal stability and good processibility. It has broad absorption in UV-visible region. Therefore, Re-DIAN exhibits good photosensitising property for photovoltaic cells. Multilayer bulk heterojunction photovoltaic cells with simple structures were fabricated base on Re-DIAN complex. The active layer consists of a blend of Re-DIAN and fullerene that were co-deposited in the same layer by vacuum deposition. The photovoltaic properties of the devices were studied by irradiaton under AM 1.5 simulated solar light. The effects of changing the co-deposition film thickness, amount of Re-DIAN photosensitizer, and hole transporting materials were studied. © 2005 Materials Research Society.published_or_final_versio

    Gastrointestinal bleeding risk with rivaroxaban vs aspirin in atrial fibrillation: a multinational study

    Get PDF
    Purpose: Comparative gastrointestinal bleeding (GIB) risk between rivaroxaban and low‐dose aspirin is unknown in patients with atrial fibrillation (AF). This study investigated GIB risk with rivaroxaban vs aspirin among two separate AF cohorts in Hong Kong and the United Kingdom, using a common protocol approach. Methods: This was a population‐based cohort study using separate data from the Clinical Data Analysis and Reporting System (CDARS) of the Hong Kong Hospital Authority (2010‐2018) and The Health Improvement Network (THIN) database in the United Kingdom (2011‐2017). Patients with AF newly prescribed aspirin or rivaroxaban were included. Cox proportional hazards regression was used to compare GIB risks for rivaroxaban vs aspirin, accounting for confounders using propensity score fine stratification approach. Results: In CDARS, 29 213 patients were included; n = 1052 (rivaroxaban), n = 28 161 (aspirin). Crude GIB event rates per 100 patient‐years in CDARS were 3.0 (aspirin) and 2.6 (rivaroxaban). No difference in GIB risk was observed between rivaroxaban and aspirin overall (HR = 1.04, 95%CI = 0.76‐1.42), and in dose‐stratified analyses (HR = 1.21, 95%CI = 0.84‐1.74 [20 mg/day]; HR = 0.80, 95%CI = 0.44‐1.45 [≤15 mg/day]). In THIN, 11 549 patients were included, n = 3496 (rivaroxaban) and n = 8053 (aspirin). Crude GIB event rates were 1.3 (aspirin) and 2.4 (rivaroxaban) per 100 patient‐years. No difference in GIB risk was observed between rivaroxaban and aspirin overall (HR = 1.40, 95%CI = 1.00‐1.98) and low‐dose rivaroxaban (≤15 mg/day) (HR = 1.00, 95%CI = 0.56‐1.30), but increased GIB risk was observed for rivaroxaban 20 mg/day vs aspirin (HR = 1.57, 95%CI = 1.08‐2.29). Conclusion: In patients with AF, GIB risk was comparable between aspirin and rivaroxaban ≤15 mg/day. GIB risk for rivaroxaban 20 mg/day vs aspirin remains uncertain and warrants further investigation

    Identification of serum miR-139-3p as a non-invasive biomarker for colorectal cancer

    Get PDF
    Aberrant levels of circulating microRNAs are potential biomarkers for the early detection of colorectal cancer. The aim of this study was to study miR-139-3p and miR-622 in serum as a non-invasive biomarker for colorectal cancer diagnosis. We applied quantitative polymerase chain reaction to determine the levels of miR-139-3p and miR-622 in 42 pairs of tumor and adjacent non-tumor tissues, and in serum samples of 117 patients and 90 control subjects. Our results showed that miR-139-3p was silenced whereas miR-622 was overexpressed in colorectal cancer. Similarly, serum miR-139-3p level was significantly lower in colorectal cancer patients than in control subjects whereas miR-622 was more frequently detectable in patients. ROC analysis showed that AUC of miR-139-3p was 0.9935, with a sensitivity of 96.6% and specificity of 97.8%. Serum miR-139-3p level showed high sensitivity and specificity for both early and late stage CRCs and proximal and distal CRCs. Detectable serum miR-622 showed a sensitivity of 87.5% and specificity of 63.5% for discriminating CRC patients, but the sensitivity dropped for late stage patients (72.7%). We also included analyses of the blood CEA level for comparing the diagnostic performance of these blood-based biomarkers. The median level in CRC patients (3.6 ng/ml) was significantly higher than that in control (1.8 ng/ml). The AUC value of CEA in diagnosing CRC patients was 0.7515. CEA showed a positive correlation with tumor stage and age of patients and its level was higher in male. Collectively, serum miR-139-3p has strong potential as a promising non-invasive biomarker in colorectal cancer detection.published_or_final_versio
    corecore