3 research outputs found

    Quantifying coronary sinus flow and global LV perfusion at 3T

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Despite the large availability of 3T MR scanners and the potential of high field imaging, this technical platform has yet to prove its usefulness in the cardiac MR setting, where 1.5T remains the established standard. Global perfusion of the left ventricle, as well as the coronary flow reserve (CFR), can provide relevant diagnostic information, and MR measurements of these parameters may benefit from increased field strength. Quantitative flow measurements in the coronary sinus (CS) provide one method to investigate these parameters. However, the ability of newly developed faster MR sequences to measure coronary flow during a breath-hold at 3T has not been evaluated.</p> <p>Methods</p> <p>The aim of this work was to measure CS flow using segmented phase contrast MR (PC MR) on a clinical 3T MR scanner. Parallel imaging was employed to reduce the total acquisition time. Global LV perfusion was calculated by dividing CS flow with left ventricular (LV) mass. The repeatability of the method was investigated by measuring the flow three times in each of the twelve volunteers. Phantom experiments were performed to investigate potential error sources.</p> <p>Results</p> <p>The average CS flow was determined to 88 ± 33 ml/min and the deduced LV perfusion was 0.60 ± 0.22 ml/min·g, in agreement with published values. The repeatability (1-error) of the three repeated measurements in each subject was on average 84%.</p> <p>Conclusion</p> <p>This work demonstrates that the combination of high field strength (3T), parallel imaging and segmented gradient echo sequences allow for quantification of the CS flow and global perfusion within a breath-hold.</p

    Cardiovascular responses to water immersion in humans: Impact on cerebral perfusion

    No full text
    Episodic increases in cerebrovascular perfusion and shear stress may have beneficial impacts on endothelial function that improve brain health. We hypothesized that water immersion to the level of the right atrium in humans would increase cerebral perfusion. We continuously measured, in 9 young (means ± SD, 24.6 ± 2.0 yr) healthy men, systemic hemodynamic variables along with blood flows in the common carotid and middle and posterior cerebral arteries during controlled filling and emptying of a water tank to the level of the right atrium. Mean arterial pressure (80 ± 9 vs. 91 ± 12 mmHg, P < 0.05), cardiac output (4.8 ± 0.7 vs. 5.1 ± 0.6 l/min, P < 0.05) and end-tidal carbon dioxide (PetCO2, 39.5 ± 2.0 vs. 44.4 ± 3.5 mmHg, P < 0.05) increased with water immersion, along with middle (59 ± 6 vs. 64 ± 6 cm/s, P < 0.05) and posterior cerebral artery blood flow velocities (41 ± 9 vs. 44 ± 10 cm/s, P < 0.05). These changes were reversed when the tank was emptied. Water immersion is associated with hemodynamic and PetCO2 changes, which increase cerebral blood velocities in humans. This study provides an evidence base for future studies to examine the potential additive effect of exercise in water on improving cerebrovascular health

    Whole-body vibration and occupational physical performance: a review

    No full text
    © 2015 Springer-Verlag Berlin Heidelberg Introduction: In the occupational environment, there are a considerable number of stressors that can affect physical performance in job tasks. Whole-body vibration (WBV), which arises from vehicle transit, is one such stressor that has been demonstrated to alter human function in several ways. This study identifies the known physical changes to human function which result from WBV, to comment on changes which may translate to performance in physically demanding occupational tasks. Methods: A systematic review is performed on the literature relating to changes in the neuromuscular, physiological and biomechanical properties of the human body, when exposed to WBV. Selection criteria are constructed to synthesise articles which strictly relate to in-vehicle WBV and physical responses. Results: In total, 29 articles were identified which satisfied the criteria for inclusion. A range of physical responses produced from WBV are presented; however, little consistency exists in study design and the responses reported. Discussion: Given the inconsistency in the reported responses, the precise changes to human function remain unknown. However, there is sufficient evidence to warrant the design of studies which investigate occupationally relevant physical performance changes following WBV
    corecore