438 research outputs found
Molecular dynamics study of solvation effects on acid dissociation in aprotic media
Acid ionization in aprotic media is studied using Molecular Dynamics
techniques. In particular, models for HCl ionization in acetonitrile and
dimethylsulfoxide are investigated. The proton is treated quantum mechanically
using Feynman path integral methods and the remaining molecules are treated
classically. Quantum effects are shown to be essential for the proper treatment
of the ionization. The potential of mean force is computed as a function of the
ion pair separation and the local solvent structure is examined. The computed
dissociation constants in both solvents differ by several orders of magnitude
which are in reasonable agreement with experimental results. Solvent separated
ion pairs are found to exist in dimethylsulfoxide but not in acetonitrile.
Dissociation mechanisms in small clusters are also investigated. Solvent
separated ion pairs persist even in aggregates composed of rather few
molecules, for instance, as few as thirty molecules. For smaller clusters or
for large ion pair separations cluster finite-size effects come into play in a
significant fashion.Comment: Plain LaTeX. To appear in JCP(March 15). Mpeg simulations available
at http://www.chem.utoronto.ca/staff/REK/Videos/clusters/clusters.htm
A Limit on the Polarized Anisotropy of the Cosmic Microwave Background at Subdegree Angular Scales
A ground-based polarimeter, PIQUE, operating at 90 GHz has set a new limit on
the magnitude of any polarized anisotropy in the cosmic microwave background.
The combination of the scan strategy and full width half maximum beam of 0.235
degrees gives broad window functions with average multipoles, l = 211+294-146
and l = 212+229-135 for the E- and B-mode window functions, respectively. A
joint likelihood analysis yields simultaneous 95% confidence level flat band
power limits of 14 and 13 microkelvin on the amplitudes of the E- and B-mode
angular power spectra, respectively. Assuming no B-modes, a 95% confidence
limit of 10 microkelvin is placed on the amplitude of the E-mode angular power
spectrum alone.Comment: 4 pages, 3 figures, submitted to Astrophysical Journal Letter
New Measurements of Fine-Scale CMB Polarization Power Spectra from CAPMAP at Both 40 and 90 GHz
We present new measurements of the cosmic microwave background (CMB)
polarization from the final season of the Cosmic Anisotropy Polarization MAPper
(CAPMAP). The data set was obtained in winter 2004-2005 with the 7 m antenna in
Crawford Hill, New Jersey, from 12 W-band (84-100 GHz) and 4 Q-band (36-45 GHz)
correlation polarimeters with 3.3' and 6.5' beamsizes, respectively. After
selection criteria were applied, 956 (939) hours of data survived for analysis
of W-band (Q-band) data. Two independent and complementary pipelines produced
results in excellent agreement with each other. A broad suite of null tests as
well as extensive simulations showed that systematic errors were minimal, and a
comparison of the W-band and Q-band sky maps revealed no contamination from
galactic foregrounds. We report the E-mode and B-mode power spectra in 7 bands
in the range 200 < l < 3000, extending the range of previous measurements to
higher l. The E-mode spectrum, which is detected at 11 sigma significance, is
in agreement with cosmological predictions and with previous work at other
frequencies and angular resolutions. The BB power spectrum provides one of the
best limits to date on B-mode power at 4.8 uK^2 (95% confidence).Comment: 19 pages, 17 figures, 2 tables, submitted to Ap
Interrater Reliability of the Wolf Motor Function Test–Functional Ability Scale: Why It Matters
Background. One important objective for clinical trialists in rehabilitation is determining efficacy of interventions to enhance motor behavior. In part, limitation in the precision of measurement presents a challenge. The few valid, low-cost observational tools available to assess motor behavior cannot escape the variability inherent in test administration and scoring. This is especially true when there are multiple evaluators and raters, as in the case of multisite randomized controlled trials (RCTs). One way to enhance reliability and reduce variability is to implement rigorous quality control (QC) procedures. Objective. This article describes a systematic QC process used to refine the administration and scoring procedures for the Wolf Motor Function Test (WMFT)–Functional Ability Scale (FAS). Methods. The QC process, a systematic focus-group collaboration, was developed and used for a phase III RCT, which enlisted multiple evaluators and an experienced WMFT-FAS rater panel. Results. After 3 staged refinements to the administration and scoring instructions, we achieved a sufficiently high interrater reliability (weighted κ = 0.8). Conclusions and Implications. A systematic focus-group process was shown to be an effective method to improve reliability of observational assessment tools for motor behavior in neurorehabilitation. A reduction in noise-related variability in performance assessments will increase power and potentially lower the number needed to treat. Improved precision of measurement can lead to more cost-effective and efficient clinical trials. Finally, we suggest that improved precision in measures of motor behavior may provide more insight into recovery mechanisms than a single measure of movement time alone
Kaon decay interferometry as meson dynamics probes
We discuss the time dependent interferences between and in the
decays in and , to be studied at interferometry machines
such as the -factory and LEAR. We emphasize the possibilities and the
advantages of using interferences, in comparison with width measurements, to
obtain information both on conserving and violating amplitudes.
Comparison with present data and suggestions for future experiments are made.Comment: 15 pages, in RevTex, Report INFNNA-IV-93-31, UTS-DFT-93-2
Reduced Upper Limb Recovery in Subcortical Stroke Patients With Small Prior Radiographic Stroke
Background: Research imaging costs limit lesion-based analyses in already expensive large stroke rehabilitation trials. Despite the belief that lesion characteristics influence recovery and treatment response, prior studies have not sufficiently addressed whether lesion features are an important consideration in motor rehabilitation trial design.Objective: Using clinically-obtained neuroimaging, evaluate how lesion characteristics relate to upper extremity (UE) recovery and response to therapy in a large UE rehabilitation trial.Methods: We reviewed lesions from 297 participants with mild-moderate motor impairment in the Interdisciplinary Comprehensive Arm Rehabilitation Evaluation (ICARE) study and their association with motor recovery, measured by the UE Fugl-Meyer (UE-FM). Significant lesion features identified on correlational and bivariate analysis were further analyzed for associations with recovery and therapy response using longitudinal mixed models.Results: Prior radiographic stroke was associated with less recovery on UE-FM in participants with motor impairment from subsequent subcortical stroke (−5.8 points) and in the overall sample (−3.6 points), but not in participants with cortical or mixed lesions. Lesion volume was also associated with less recovery, particularly after subcortical stroke. Every decade increase in age was associated with 1 less point of recovery on UE-FM. Response to specific treatment regimens varied based on lesion characteristics. Subcortical stroke patients experienced slightly less recovery with higher doses of upper extremity task-oriented training. Participants with cortical or mixed lesions experienced more recovery with higher doses of usual and customary therapy. Other imaging features (leukoaraiosis, ischemic vs. hemorrhagic stroke) were not significant.Conclusions: ICARE clinical imaging revealed information useful for UE motor trial design: stratification of persons with and without prior radiographic stroke may be required in participants with subcortical stroke, the majority of motor rehabilitation trial participants. Most of the prior radiographic strokes were small and cortically-based, suggesting even minor prior brain injury remote to the acute stroke lesion may limit spontaneous and therapy-related recovery. Lesion location may be associated with response to different therapy regimens, but the effects are variable and of unclear significance
Measurement of the Phase Difference Between eta00 and eta+- to a Precision of 1^0
We propose to add an additional regenerator to the E731 spectrometer in the MC beamline to enable us to measure the phase difference between the CP violation parameters {eta}{sub 00} and {eta}{sub +-} to an accuracy of 1{sup o}. Very general considerations indicate that CPT conservation requires the phase difference, {Delta}{phi} = Arg({eta}{sub 00}) - Arg({eta}{sub +-}), to be smaller than one degree. The current experimental value is {Delta}{phi} = (9.4 {+-} 5.1){sup o}
Rare Kaon Decays
The current status of rare kaon decay experiments is reviewed. New limits in
the search for Lepton Flavor Violation are discussed, as are new measurements
of the CKM matrix.Comment: 8 pages, 3 figures, LaTeX, presented at the 3rd International
Conference on B Phyiscs and CP Violation, Taipei December 3-7, 199
Socially assistive robotics for post-stroke rehabilitation
BACKGROUND: Although there is a great deal of success in rehabilitative robotics applied to patient recovery post stroke, most of the research to date has dealt with providing physical assistance. However, new rehabilitation studies support the theory that not all therapy need be hands-on. We describe a new area, called socially assistive robotics, that focuses on non-contact patient/user assistance. We demonstrate the approach with an implemented and tested post-stroke recovery robot and discuss its potential for effectiveness. RESULTS: We describe a pilot study involving an autonomous assistive mobile robot that aids stroke patient rehabilitation by providing monitoring, encouragement, and reminders. The robot navigates autonomously, monitors the patient's arm activity, and helps the patient remember to follow a rehabilitation program. We also show preliminary results from a follow-up study that focused on the role of robot physical embodiment in a rehabilitation context. CONCLUSION: We outline and discuss future experimental designs and factors toward the development of effective socially assistive post-stroke rehabilitation robots
Improved KL->pi e nu Form Factor and Phase Space Integral with Reduced Model Uncertainty
Using the published KTeV sample of 2 million KL-> pi e nu decays and a new
form factor expansion with a rigorous bound on higher order terms, we present a
new determination of the KL->pi e nu form factor and phase space integral.
Compared to the previous KTeV result, the uncertainty in the new form factor
expansion is negligible and results in an overall uncertainty in the phase
space integral (IKe) that is a factor of two smaller: IKe = 0.15392 +- 0.00048
\.Comment: 3 pages, 2 figures, submitted to PRD Rapid Communicatio
- …