3,671 research outputs found
A general representation for axial-flow fans and turbines
A general representation of fan and turbine arrangements on a single classification chart is presented that is made possible by a particular definition of the stage of an axial-flow fan or turbine. Several unconventional fan and turbine arrangements are indicated and the applications of these arrangements are discussed
Originalism and Brown v. Board of Education
Article published in the Michigan State Law Review
A terrestrial search for dark contents of the vacuum, such as dark energy, using atom interferometry
We describe the theory and first experimental work on our concept for
searching on earth for the presence of dark content of the vacuum (DCV) using
atom interferometry. Specifically, we have in mind any DCV that has not yet
been detected on a laboratory scale, but might manifest itself as dark energy
on the cosmological scale. The experimental method uses two atom
interferometers to cancel the effect of earth's gravity and diverse noise
sources. It depends upon two assumptions: first, that the DCV possesses some
space inhomogeneity in density, and second that it exerts a sufficiently strong
non-gravitational force on matter. The motion of the apparatus through the DCV
should then lead to an irregular variation in the detected matter-wave phase
shift. We discuss the nature of this signal and note the problem of
distinguishing it from instrumental noise. We also discuss the relation of our
experiment to what might be learned by studying the noise in gravitational wave
detectors such as LIGO.The paper concludes with a projection that a future
search of this nature might be carried out using an atom interferometer in an
orbiting satellite. The apparatus is now being constructed
Originalism and Brown v. Board of Education
Article published in the Michigan State Law Review
Is the Top Quark Really Heavier than the Boson?
Scalar induced top decays may drastically suppress
and still hide the top below . The collider experiments should
enlarge the scope and study the plane. Specific model
signatures such as (multiple high -jets) and
, (with $B(t\to b\tau\nu) \
\raisebox{-.5ex}{\rlap{}} \raisebox{.4ex}{}\ 1/3t^\primeb^\prime$ quark,
while top quark and toponium physics could still turn up at LEP-II.Comment: 11 pages (RevTex), 3 figures (not included), NTUTH-93-0
Alignment of retention time obtained from multicapillary column gas chromatography used for VOC analysis with ion mobility spectrometry
Multicapillary column (MCC) ion mobility spectrometers (IMS) are increasingly in demand for medical diagnosis, biological applications and process control. In a MCC-IMS, volatile compounds are differentiated by specific retention time and ion mobility when rapid preseparation techniques are applied, e.g. for the analysis of complex and humid samples. Therefore, high accuracy in the determination of both parameters is required for reliable identification of the signals. The retention time in the MCC is the subject of the present investigation because, for such columns, small deviations in temperature and flow velocity may cause significant changes in retention time. Therefore, a universal correction procedure would be a helpful tool to increase the accuracy of the data obtained from a gas-chromatographic preseparation. Although the effect of the carrier gas flow velocity and temperature on retention time is not linear, it could be demonstrated that a linear alignment can compensate for the changes in retention time due to common minor deviations of both the carrier gas flow velocity and the column temperature around the MCC-IMS standard operation conditions. Therefore, an effective linear alignment procedure for the correction of those deviations has been developed from the analyses of defined gas mixtures under various experimental conditions. This procedure was then applied to data sets generated from real breath analyses obtained in clinical studies using different instruments at different measuring sites for validation. The variation in the retention time of known signals, especially for compounds with higher retention times, was significantly improved. The alignment of the retention time—an indispensable procedure to achieve a more precise identification of analytes—using the proposed method reduces the random error caused by small accidental deviations in column temperature and flow velocity significantly
- …