241 research outputs found

    Mn valence instability in La2/3Ca1/3MnO3 thin films

    Full text link
    A Mn valence instability on La2/3Ca1/3MnO3 thin films, grown on LaAlO3 (001)substrates is observed by x-ray absorption spectroscopy at the Mn L-edge and O K-edge. As-grown samples, in situ annealed at 800 C in oxygen, exhibit a Curie temperature well below that of the bulk material. Upon air exposure a reduction of the saturation magnetization, MS, of the films is detected. Simultaneously a Mn2+ spectral signature develops, in addition to the expected Mn3+ and Mn4+ contributions, which increases with time. The similarity of the spectral results obtained by total electron yield and fluorescence yield spectroscopy indicates that the location of the Mn valence anomalies is not confined to a narrow surface region of the film, but can extend throughout the whole thickness of the sample. High temperature annealing at 1000 C in air, immediately after growth, improves the magnetic and transport properties of such films towards the bulk values and the Mn2+ signature in the spectra does not appear. The Mn valence is then stable even to prolonged air exposure. We propose a mechanism for the Mn2+ ions formation and discuss the importance of these observations with respect to previous findings and production of thin films devices.Comment: Double space, 21 pages, 6 figure

    Disorder effects in electronic structure of substituted transition metal compounds

    Get PDF
    Investigating LaNi(1-x)M(x)O3 (M = Mn and Fe), we identify a characteristic evolution of the spectral function with increasing disorder in presence of strong interaction effects across the metal-insulator transition. We discuss these results vis-a-vis existing theories of electronic structure in simultaneous presence of disorder and interaction.Comment: Revtex, 4 pages, 3 postscript figures (To appear in Phys. Rev. Lett

    Determination of total x-ray absorption coefficient using non-resonant x-ray emission

    Get PDF
    An alternative measure of x-ray absorption spectroscopy (XAS) called inverse partial fluorescence yield (IPFY) has recently been developed that is both bulk sensitive and free of saturation effects. Here we show that the angle dependence of IPFY can provide a measure directly proportional to the total x-ray absorption coefficient, µ(E). In contrast, fluorescence yield (FY) and electron yield (EY) spectra are offset and/or distorted from µ(E) by an unknown and difficult to measure amount. Moreover, our measurement can determine µ(E) in absolute units with no free parameters by scaling to µ(E) at the non-resonant emission energy. We demonstrate this technique with measurements on NiO and NdGaO3. Determining µ(E) across edge-steps enables the use of XAS as a non-destructive measure of material composition. In NdGaO3, we also demonstrate the utility of IPFY for insulating samples, where neither EY or FY provide reliable spectra due to sample charging and self-absorption effects, respectively

    Phlebologie an deutschen Hautkliniken: eine Bestandsaufnahme im Auftrag der Deutschen Gesellschaft fĂĽr Phlebologie

    Get PDF
    Reich-Schupke S, Alm J, Altmeyer P, et al. Phlebologie an deutschen Hautkliniken: Eine Bestandsaufnahme im Auftrag der Deutschen Gesellschaft für Phlebologie. Hautarzt. 2013;64(9):685-694.Phlebologic diseases have become extremely common and have major socio-economic impact. However, the percentage of dermatologists working in phlebology appears to be decreasing according to the data of the German Society of Phlebology (DGP). To investigate the reasons for this development, we-on behalf of the DGP-sent a questionnaire to 120 German Departments of Dermatology in autumn 2012. In 76 returned questionnaires, the number of physicians with additional fellowship training in phlebology averaged 1.5; the average number of those who fulfill the criteria for training fellows in phlebology was 0.9. In 71.1 % of the departments there was a phlebologist. A special phlebologic outpatient clinic existed in 73.7 % of the departments. Sonography with Doppler (89.5 %) and duplex (86.8 %) was used as the most frequent diagnostic tool. For therapy, compression (94.7 %), sclerotherapy (liquid 78.9 %, foam 63.2 %, catheter 18.4 %), endoluminal thermic procedures (radio wave 28.9 %, laser 17.1 %) and surgery (especially crossectomy and stripping 67.1 %, phlebectomy of tributaries 75 %) were used. The average number of treatments was very heterogenous in the different departments. Phlebology definitely plays an important role in dermatology. Most departments fulfill the formal criteria for the license to conduct advanced training in phlebology. A wide spectrum of phlebological diagnostic and therapeutic procedures is available.Hintergrund Venenleiden sind eine Volkskrankheit und haben eine enorme sozioökonomische Bedeutung. Dennoch scheint der Anteil der phlebologisch tätigen Dermatologen entsprechend den Zahlen der Deutschen Gesellschaft für Phlebologie (DGP) abzunehmen. Methoden Um die Ursachen dieser Entwicklung zu untersuchen, führten wir im Herbst 2012 im Auftrag der DGP eine Befragungsstudie zur Phlebologie an 120 deutschen Hautkliniken durch. Ergebnisse In 76 antwortenden Klinien gab es im Mittel 1,5 Phlebologen und 0,9 Ärzte mit Voraussetzungen zur Weiterbildungsermächtigung Phlebologie. In 71,1 % der Kliniken gab es einen Phlebologen, in 73,7 % eine phlebologische Sprechstunde. Zur Diagnostik wurden besonders die Doppler- (89,5 %) und Duplexsonographie (86,8 %) eingesetzt. In der Therapie führte die Kompressionstherapie (94,7 %), gefolgt von Sklerosierungstherapien (flüssig 78,9 %, Schaum 63,2 %, Katheter 18,4 %), den endoluminalen thermischen Verfahren (Radiowelle 28,9 %, Laser 17,1 %) und den operativen Eingriffen (vor allem Cross- und Saphenektomie 67,1 %, Seitenastexhairese 75 %). Die durchschnittlichen Behandlungszahlen waren sehr heterogen. Schlussfolgerung Die Phlebologie spielt in der Dermatologie weiterhin eine wichtige Rolle. Mehrheitlich sind in den Kliniken die Möglichkeiten zur Weiterbildung Phlebologie gegeben. Es wird ein breites Spektrum an phlebologischen Techniken zur Diagnostik und Therapie angeboten
    • …
    corecore