375 research outputs found

    ppppωpp\to pp\omega reaction near threshold

    Full text link
    We analyze the total cross section data for ppppωpp \to pp\omega near threshold measured recently at SATURNE. Using an effective range approximation for the on-shell pppp S-wave final state interaction we extract from these data the modulus Ω=0.53|\Omega| = 0.53 fm4^4 of the threshold transition amplitude Ω\Omega. We present a calculation of various (tree-level) meson exchange diagrams contributing to Ω\Omega. It is essential that ω\omega-emission from the anomalous ωρπ\omega\rho\pi-vertex interferes destructively with ω\omega-emission from the proton lines. The contribution of scalar σ\sigma-meson exchange to Ω\Omega turns out to be negligibly small. Without introducing off-shell meson-nucleon form factors the experimental value Ω=0.53|\Omega|=0.53 fm4^4 can be reproduced with an ωN\omega N-coupling constant of gωN=10.7g_{\omega N}=10.7. The results of the present approach agree qualitatively with the J\"ulich model. We also perform a combined analysis of the reactions ppppπ0,pnπ+,ppη,ppωpp\to pp\pi^0, pn\pi^+, pp\eta, pp\omega and pnpnηpn\to pn\eta near threshold.Comment: Latex-file 6 pages, 2 Figure

    Development of an improved oxygen electrode for use in alkaline H2-O2 fuel cells Quarterly report, Apr. 1 - Jun. 30, 1967

    Get PDF
    Preparation of institial compounds of transition metals for hydrogen oxygen fuel cell cathode

    Intraocular pressure fluctuations in professional brass and woodwind musicians during common playing conditions.

    Get PDF
    BACKGROUND: We investigated the effects on intraocular pressure (IOP) and blood pressure (BP) of playing brass and woodwind instruments by monitoring IOP and BP in a representative group of professional musicians under a variety of common playing conditions. METHODS: IOP and BP measurements were recorded from 37 brass and 15 woodwind instrument players, before and after playing tones of low, middle and high frequency. We also measured IOP and BP before and during playing common exercises of 10 minutes duration, as well as after playing a sustained high-pitched tone, to test for changes in IOP under conditions of maximum effort. RESULTS: Playing tones on brass and woodwind instruments causes a temporary elevation in IOP and BP, depending on the tone frequency: brass instrument players showed a significant elevation after playing high and middle frequency tones (p < 0.0001) whereas woodwind instrument players showed a significant increase only for high frequencies (e.g., oboe, 17 ± 2.9 mm Hg to 21 ± 4.4 mm Hg; p = 0.017). Playing a typical exercise of 10 minutes temporarily increased IOP in both groups of musicians. Finally, playing a sustained tone of high pitch caused a significant elevation in IOP in brass instrument players only (16.6 ± 3.5 mm Hg to 23.3 ± 8.9 mm Hg; p < 0.0001). CONCLUSIONS: The temporary and sometimes dramatic elevations and fluctuations in IOP observed in this study, coupled with daily exposure to instrument play, puts professional wind instrument players at increased risk of developing glaucoma. Consequently, these musicians should be monitored for signs of glaucoma, especially those with co-existing risk factors

    Global Grid User Support Building a worldwide distributed user support infrastructure

    Get PDF
    The organisation and management of the user support in a global escience computing infrastructure such as EGEE (Enabling Grids for E-sciencE), a series of EU projects, is one of the challenges of the Grid. Given the widely distributed nature of the organisation, and the spread of expertise for installing, configuring, managing and troubleshooting the Grid middleware services, a standard centralised model could not be deployed in EGEE. This paper presents the model used in EGEE for building a reliable infrastructure for user, virtual organisation and operations support. A short overview of EGEE is given. The model for supporting a production quality infrastructure for scientific applications will be described in detail. The advantages of the chosen model will be presented and the possible difficulties will be discussed. In this paper we will also describe a scheme of how knowledge management can be used in Grid user support and first steps towards a realisation in the framework of the EGEE user support infrastructure

    Knowledge Management and Semantics in Global Grid User Support

    Get PDF
    The organisation and management of the user support in a global escience computing infrastructure such as EGEE (Enabling Grids for E-sciencE), a series of EU projects, is one of the challenges of the Grid. Given the widely distributed nature of the organisation, and the spread of expertise for installing, configuring, managing and troubleshooting the Grid middleware services, a standard centralised model could not be deployed in EGEE. This paper presents the model used in EGEE for building a reliable infrastructure for user, virtual organisation and operations support. A short overview of EGEE is given. The model for supporting a production quality infrastructure for scientific applications will be described in detail. The advantages of the chosen model will be presented and the possible difficulties will be discussed. In this paper we will also describe a scheme of how knowledge management can be used in Grid user support and first steps towards a realisation in the framework of the EGEE user support infrastructure

    Functional approach to the electromagnetic response function: the Longitudinal Channel

    Get PDF
    In this paper we address the (charge) longitudinal electromagnetic response for a homogeneous system of nucleons interacting via meson exchanges in the functional framework. This approach warrants consistency if the calculation is carried on order-by-order in the mesonic loop expansion with RPA-dressed mesonic propagators. At the 1-loop order and considering pion, rho and omega exchanges we obtain a quenching of the response, in line with the experimental results.Comment: RevTeX, 18 figures available upon request - to be published in Physical Review

    The size of the proton - closing in on the radius puzzle

    Get PDF
    We analyze the recent electron-proton scattering data from Mainz using a dispersive framework that respects the constraints from analyticity and unitarity on the nucleon structure. We also perform a continued fraction analysis of these data. We find a small electric proton charge radius, r_E^p = 0.84_{-0.01}^{+0.01} fm, consistent with the recent determination from muonic hydrogen measurements and earlier dispersive analyses. We also extract the proton magnetic radius, r_M^p = 0.86_{-0.03}^{+0.02} fm, consistent with earlier determinations based on dispersion relations.Comment: 4 pages, 2 figures, fit improved, small modifications, section on continued fractions modified, conclusions on the proton charge radius unchanged, version accepted for publication in European Physical Journal

    Rumors of disease in the global village: outbreak verification.

    Get PDF
    Emerging infectious diseases and the growth of information technology have produced new demands and possibilities for disease surveillance and response. Increasing numbers of outbreak reports must be assessed rapidly so that control efforts can be initiated and unsubstantiated reports can be identified to protect countries from unnecessary economic damage. The World Health Organization has set up a process for timely outbreak verification to convert large amounts of data into accurate information for suitable action. We describe the context and processes of outbreak verification and information dissemination

    Low-noise RF-amplifier-free slab-coupled optical waveguide coupled optoelectronic oscillators: physics and operation

    Get PDF
    We demonstrate a 10-GHz RF-amplifier-free slab-coupled optical waveguide coupled optoelectronic oscillator (SCOW-COEO) system operating with low phase-noise (-115 dBc/Hz at 1 kHz offset) and large sidemode suppression (70 dB measurement-limited). The optical pulses generated by the SCOW-COEO exhibit 26.8-ps pulse width (post compression) with a corresponding spectral bandwidth of 0.25 nm (1.8X transform-limited). We also investigate the mechanisms that limit the performance of the COEO. Our measurements indicate that degradation in the quality factor (Q) of the optical cavity significantly impacts COEO phase-noise through increases in the optical amplifier relative intensity noise (RIN)
    corecore