137 research outputs found

    Born blonde: a recessive loss-of-function mutation in the melanocortin 1 receptor is associated with cream coat coloration in Antarctic fur seals

    Get PDF
    Although the genetic basis of color variation has been extensively studied in humans and domestic animals, the genetic polymorphisms responsible for different color morphs remain to be elucidated in many wild vertebrate species. For example, hypopigmentation has been observed in numerous marine mammal species but the underlying mutations have not been identified. A particularly compelling candidate gene for explaining color polymorphism is the melanocortin 1 receptor (MC1R), which plays a key role in the regulation of pigment production. We therefore used Antarctic fur seals (Arctocephalus gazella) as a highly tractable marine mammal system with which to test for an association between nucleotide variation at the MC1R and melanin-based coat color phenotypes. By sequencing 70 wild-type individuals with dark-colored coats and 26 hypopigmented individuals with cream-colored coats, we identified a nonsynonymous mutation that results in the substitution of serine with phenylalanine at an evolutionarily highly conserved structural domain. All of the hypopigmented individuals were homozygous for the allele coding for phenylalanine, consistent with a recessive loss-of-function allele. In order to test for cryptic population structure, which can generate artefactual associations, and to evaluate whether homozygosity at the MC1R could be indicative of low genome-wide heterozygosity, we also genotyped all of the individuals at 50 polymorphic microsatellite loci. We were unable to detect any population structure and also found that wild-type and hypopigmented individuals did not differ significantly in their standardized multilocus heterozygosity. Such a lack of association implies that hypopigmented individuals are unlikely to suffer disproportionately from inbreeding depression, and hence, we have no reason to believe that they are at a selective disadvantage in the wider population

    τ\tauSPECT: A spin-flip loaded magnetic ultracold neutron trap for a determination of the neutron lifetime

    Full text link
    The confinement of ultracold neutrons (UCNs) in a three dimensional magnetic field gradient trap allows for a measurement of the free neutron lifetime with superior control over spurious loss channels and can provide a large kinetic energy acceptance to enhance statistical sensitivity. In this paper, we present the first successful implementation of a pulsed spin-flip based loading scheme for a three-dimensional magnetic UCN trap. The measurements with the τ\tauSPECT experiment were performed at the pulsed UCN source of the research reactor TRIGA Mainz. We report on detailed investigations of major systematic effects influencing the neutron storage time, statistically limited by the size of the recorded data set. The extracted neutron storage time constant of τ=859(16)s\tau = 859(16)\mathrm{s} is compatible with, but not to be interpreted as, a measurement of the free neutron lifetime.Comment: 15 pages, 19 figure

    An Improved Search for the Neutron Electric Dipole Moment

    Full text link
    A permanent electric dipole moment of fundamental spin-1/2 particles violates both parity (P) and time re- versal (T) symmetry, and hence, also charge-parity (CP) symmetry since there is no sign of CPT-violation. The search for a neutron electric dipole moment (nEDM) probes CP violation within and beyond the Stan- dard Model. The experiment, set up at the Paul Scherrer Institute (PSI), an improved, upgraded version of the apparatus which provided the current best experimental limit, dn < 2.9E-26 ecm (90% C.L.), by the RAL/Sussex/ILL collaboration: Baker et al., Phys. Rev. Lett. 97, 131801 (2006). In the next two years we aim to improve the sensitivity of the apparatus to sigma(dn) = 2.6E-27 ecm corresponding to an upper limit of dn < 5E-27 ecm (95% C.L.), in case for a null result. In parallel the collaboration works on the design of a new apparatus to further increase the sensitivity to sigma(dn) = 2.6E-28 ecm.Comment: APS Division for particles and fields, Conference Proceedings, Two figure

    Testing isotropy of the universe using the Ramsey resonance technique on ultracold neutron spins

    Get PDF
    Physics at the Planck scale could be revealed by looking for tiny violations of fundamental symmetries in low energy experiments. In 2008, a sensitive test of the isotropy of the Universe using has been performed with stored ultracold neutrons (UCN), this is the first clock-comparison experiment performed with free neutrons. During several days we monitored the Larmor frequency of neutron spins in a weak magnetic field using the Ramsey resonance technique. An non-zero cosmic axial field, violating rotational symmetry, would induce a daily variation of the precession frequency. Our null result constitutes one of the most stringent tests of Lorentz invariance to date.Comment: proceedings of the PNCMI2010 conferenc

    Gravitational depolarization of ultracold neutrons: comparison with data

    Get PDF
    We compare the expected effects of so-called gravitationally enhanced depolarization of ultracold neutrons to measurements carried out in a spin-precession chamber exposed to a variety of vertical magnetic-field gradients. In particular, we have investigated the dependence upon these field gradients of spin-depolarization rates and also of shifts in the measured neutron Larmor precession frequency. We find excellent qualitative agreement, with gravitationally enhanced depolarization accounting for several previously unexplained features in the data

    Measurement of the permanent electric dipole moment of the neutron

    Get PDF
    We present the result of an experiment to measure the electric dipole moment EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-199 co-magnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic field changes. The statistical analysis was performed on blinded datasets by two separate groups while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is d_{\rm n} = (0.0\pm1.1_{\rm stat}\pm0.2_{\rmsys})\times10^{-26}e\,{\rm cm}

    First observation of cyclotron radiation from MeV-scale epm{\rm e}^{pm} following nuclear beta decay

    Full text link
    We present an apparatus for detection of cyclotron radiation that allows a frequency-based beta energy determination in the 5 keV to 5 MeV range, characteristic of nuclear beta decays. The cyclotron frequency of the radiating beta particles in a magnetic field is used to determine the beta energy precisely. Our work establishes the foundation to apply the cyclotron radiation emission spectroscopy (CRES) technique, developed by the Project 8 collaboration, far beyond the 18-keV tritium endpoint region. We report initial measurements of beta^-s from 6He and beta^+s from 19Ne decays to demonstrate the broadband response of our detection system and assess potential systematic uncertainties for beta spectroscopy over the full (MeV) energy range. This work is an important benchmark for the practical application of the CRES technique to a variety of nuclei, in particular, opening its reach to searches for evidence of new physics beyond the TeV scale via precision beta-decay measurements

    The very large n2EDM magnetically shielded room with an exceptional performance for fundamental physics measurements.

    Get PDF
    We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute, which features an interior cubic volume with each side of length 2.92 m, thus providing an accessible space of 25 m3. The MSR has 87 openings of diameter up to 220 mm for operating the experimental apparatus inside and an intermediate space between the layers for housing sensitive signal processing electronics. The characterization measurements show a remanent magnetic field in the central 1 m3 below 100 pT and a field below 600 pT in the entire inner volume, up to 4 cm to the walls. The quasi-static shielding factor at 0.01 Hz measured with a sinusoidal 2 μT peak-to-peak signal is about 100 000 in all three spatial directions and increases rapidly with frequency to reach 108 above 1 Hz

    Observation of gravitationally induced vertical striation of polarized ultracold neutrons by spin-echo spectroscopy

    Get PDF
    We describe a spin-echo method for ultracold neutrons (UCNs) confined in a precession chamber and exposed to a |B 0 |=1  μT magnetic field. We have demonstrated that the analysis of UCN spin-echo resonance signals in combination with knowledge of the ambient magnetic field provides an excellent method by which to reconstruct the energy spectrum of a confined ensemble of neutrons. The method takes advantage of the relative dephasing of spins arising from a gravitationally induced striation of stored UCNs of different energies, and also permits an improved determination of the vertical magnetic-field gradient with an exceptional accuracy of 1.1  pT/cm . This novel combination of a well-known nuclear resonance method and gravitationally induced vertical striation is unique in the realm of nuclear and particle physics and should prove to be invaluable for the assessment of systematic effects in precision experiments such as searches for an electric dipole moment of the neutron or the measurement of the neutron lifetime
    corecore