72 research outputs found
An analytic and systematic framework for estimating metabolic flux ratios from 13C tracer experiments
<p>Abstract</p> <p>Background</p> <p>Metabolic fluxes provide invaluable insight on the integrated response of a cell to environmental stimuli or genetic modifications. Current computational methods for estimating the metabolic fluxes from <sup>13</sup><it>C </it>isotopomer measurement data rely either on manual derivation of analytic equations constraining the fluxes or on the numerical solution of a highly nonlinear system of isotopomer balance equations. In the first approach, analytic equations have to be tediously derived for each organism, substrate or labelling pattern, while in the second approach, the global nature of an optimum solution is difficult to prove and comprehensive measurements of external fluxes to augment the <sup>13</sup><it>C </it>isotopomer data are typically needed.</p> <p>Results</p> <p>We present a novel analytic framework for estimating metabolic flux ratios in the cell from <sup>13</sup><it>C </it>isotopomer measurement data. In the presented framework, equation systems constraining the fluxes are derived automatically from the model of the metabolism of an organism. The framework is designed to be applicable with all metabolic network topologies, <sup>13</sup><it>C </it>isotopomer measurement techniques, substrates and substrate labelling patterns.</p> <p>By analyzing nuclear magnetic resonance (NMR) and mass spectrometry (MS) measurement data obtained from the experiments on glucose with the model micro-organisms <it>Bacillus subtilis </it>and <it>Saccharomyces cerevisiae </it>we show that our framework is able to automatically produce the flux ratios discovered so far by the domain experts with tedious manual analysis. Furthermore, we show by <it>in silico </it>calculability analysis that our framework can rapidly produce flux ratio equations – as well as predict when the flux ratios are unobtainable by linear means – also for substrates not related to glucose.</p> <p>Conclusion</p> <p>The core of <sup>13</sup><it>C </it>metabolic flux analysis framework introduced in this article constitutes of flow and independence analysis of metabolic fragments and techniques for manipulating isotopomer measurements with vector space techniques. These methods facilitate efficient, analytic computation of the ratios between the fluxes of pathways that converge to a common junction metabolite. The framework can been seen as a generalization and formalization of existing tradition for computing metabolic flux ratios where equations constraining flux ratios are manually derived, usually without explicitly showing the formal proofs of the validity of the equations.</p
Investigating CTL Mediated Killing with a 3D Cellular Automaton
Cytotoxic T lymphocytes (CTLs) are important immune effectors against intra-cellular pathogens. These cells search for infected cells and kill them. Recently developed experimental methods in combination with mathematical models allow for the quantification of the efficacy of CTL killing in vivo and, hence, for the estimation of parameters that characterize the effect of CTL killing on the target cell populations. It is not known how these population-level parameters relate to single-cell properties. To address this question, we developed a three-dimensional cellular automaton model of the region of the spleen where CTL killing takes place. The cellular automaton model describes the movement of different cell populations and their interactions. Cell movement patterns in our cellular automaton model agree with observations from two-photon microscopy. We find that, despite the strong spatial nature of the kinetics in our cellular automaton model, the killing of target cells by CTLs can be described by a term which is linear in the target cell frequency and saturates with respect to the CTL levels. Further, we find that the parameters describing CTL killing on the population level are most strongly impacted by the time a CTL needs to kill a target cell. This suggests that the killing of target cells, rather than their localization, is the limiting step in CTL killing dynamics given reasonable frequencies of CTL. Our analysis identifies additional experimental directions which are of particular importance to interpret estimates of killing rates and could advance our quantitative understanding of CTL killing
13C Metabolic Flux Analysis Identifies an Unusual Route for Pyruvate Dissimilation in Mycobacteria which Requires Isocitrate Lyase and Carbon Dioxide Fixation
Mycobacterium tuberculosis requires the enzyme isocitrate lyase (ICL) for growth and virulence in vivo. The demonstration that M. tuberculosis also requires ICL for survival during nutrient starvation and has a role during steady state growth in a glycerol limited chemostat indicates a function for this enzyme which extends beyond fat metabolism. As isocitrate lyase is a potential drug target elucidating the role of this enzyme is of importance; however, the role of isocitrate lyase has never been investigated at the level of in vivo fluxes. Here we show that deletion of one of the two icl genes impairs the replication of Mycobacterium bovis BCG at slow growth rate in a carbon limited chemostat. In order to further understand the role of isocitrate lyase in the central metabolism of mycobacteria the effect of growth rate on the in vivo fluxes was studied for the first time using 13C-metabolic flux analysis (MFA). Tracer experiments were performed with steady state chemostat cultures of BCG or M. tuberculosis supplied with 13C labeled glycerol or sodium bicarbonate. Through measurements of the 13C isotopomer labeling patterns in protein-derived amino acids and enzymatic activity assays we have identified the activity of a novel pathway for pyruvate dissimilation. We named this the GAS pathway because it utilizes the Glyoxylate shunt and Anapleurotic reactions for oxidation of pyruvate, and Succinyl CoA synthetase for the generation of succinyl CoA combined with a very low flux through the succinate – oxaloacetate segment of the tricarboxylic acid cycle. We confirm that M. tuberculosis can fix carbon from CO2 into biomass. As the human host is abundant in CO2 this finding requires further investigation in vivo as CO2 fixation may provide a point of vulnerability that could be targeted with novel drugs. This study also provides a platform for further studies into the metabolism of M. tuberculosis using 13C-MFA
The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory. Athena is a versatile observatory designed to address the Hot and Energetic Universe science theme, as selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), X-IFU aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over a hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR (i.e. in the course of its preliminary definition phase, so-called B1), browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters, such as the instrument efficiency, spectral resolution, energy scale knowledge, count rate capability, non X-ray background and target of opportunity efficiency. Finally, we briefly discuss the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, touch on communication and outreach activities, the consortium organisation and the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. The X-IFU will be provided by an international consortium led by France, The Netherlands and Italy, with ESA member state contributions from Belgium, Czech Republic, Finland, Germany, Poland, Spain, Switzerland, with additional contributions from the United States and Japan.The French contribution to X-IFU is funded by CNES, CNRS and CEA. This work has been also supported by ASI (Italian Space Agency) through the Contract 2019-27-HH.0, and by the ESA (European Space Agency) Core Technology Program (CTP) Contract No. 4000114932/15/NL/BW and the AREMBES - ESA CTP No.4000116655/16/NL/BW. This publication is part of grant RTI2018-096686-B-C21 funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe”. This publication is part of grant RTI2018-096686-B-C21 and PID2020-115325GB-C31 funded by MCIN/AEI/10.13039/501100011033
Integrated assessment of contaminants and monitoring of an urbanized temperate harbor (Montevideo, Uruguay): a 12-year comparison
AbstractSituated opposite the Freshwater Front, Montevideo city with its more than 1.5 million inhabitants encircles Montevideo Bay, where one of the most active and polluted harbors in South America is located. Faecal sterols, trace metals, organochlorine compounds and petroleum derivatives in the sediments of Montevideo Harbor were evaluated and their spatial distribution inside the harbor as well as in the input of two main tributary streams analyzed. Specifically for the harbor sites, a temporal comparison of metal and hydrocarbons was made with previous measurements taken 12 years ago. Clear changes were observed at these sites. The concentration of metals such as Pb, Cr and Zn have diminished, while aliphatic hydrocarbons have increased their values at almost all of the stations studied. Differences were observed between summer and winter suggesting sedimentation, input or hydrodynamic changes in the area. These results help one to understand the present situation and develop the management measures needed to improve the environmental quality of the harbor and bay
New Tools for Mass Isotopomer Data Evaluation in 13C Flux Analysis: Mass Isotope Correction, Data Consistency Checking, and Precursor Relationships
13C metabolic flux analysis (MFA) is based on carbon-labeling experiments where a specifically (13)C labeled substrate is fed. The labeled carbon atoms distribute over the metabolic network and the label enrichment of certain metabolic pools is measured by using different methods. Recently, MS methods have been dramatically improved-large and precise datasets are now available. MS data has to be preprocessed and corrected for natural stable mass isotopes. In this article we present (1). a new elegant method to correct MS measurement data for natural stable mass isotopes by infinite dimensional matrix calculus and (2). we statistically analyze and discuss a reconstruction of labeling pattern in metabolic precursors from biosynthesis molecules. Moreover, we establish a new method for consistency checking of MS spectra that can be applied for automatic error recognition in high-throughput flux analysis procedures. Preprocessing the measurement data changes their statistical properties which have to be considered in the subsequent parameter fitting process for (13)C MFA. We show that correcting for stable mass isotopes leads to rather small correlations. On the other hand, a direct reconstruction of a precursor labeling pattern from an aromatic amino acid measurement turns out to be critical. Reasonable results are only obtained if additional, independent information about the labeling of at least one precursor is available. A versatile MatLab tool for the rapid correction and consistency checking of MS spectra is presented. Practical examples for the described methods are also given
- …