1,853 research outputs found
Vibration Budget for SuperB
International audienceWe present a vibration budget for the SuperB accelerator. This includes ground motion data, motion sensitivity of machine components, and beam feedback system requirements
Modifying the surface electronic properties of YBa2Cu3O7-delta with cryogenic scanning probe microscopy
We report the results of a cryogenic study of the modification of
YBa2Cu3O7-delta surface electronic properties with the probe of a scanning
tunneling microscope (STM). A negative voltage applied to the sample during STM
tunneling is found to modify locally the conductance of the native degraded
surface layer. When the degraded layer is removed by etching, the effect
disappears. An additional surface effect is identified using Scanning Kelvin
Probe Microscopy in combination with STM. We observe reversible surface
charging for both etched and unetched samples, indicating the presence of a
defect layer even on a surface never exposed to air.Comment: 6 pages, 4 figures. To appear in Superconductor Science and
Technolog
First use of Timepix3 hybrid pixel detectors in ultra-high vacuum for beam profile measurements
A transverse beam gas ionization profile monitor is currently under development for the CERN Proton Synchrotron (PS) to provide non-destructive continuous measurements during a beam cycle. The implementation is exploring a novel use of the Timepix3 hybrid pixel detector mounted inside the ultra-high vacuum of the accelerator beam pipe to provide direct detection of ionization electrons. In early 2017, a prototype monitor was installed and has been used successfully to measure the transverse beam profile. The evolution of the transverse beam profile throughout the beam cycle has been measured and specific time windows within a beam cycle have been studied, for example the transition crossing. A radiation tolerant readout system for the Timepix3 detectors has been implemented which enables the connection of up to four detectors located in a highly radioactive environment. The first version of the readout was installed together with the prototype monitor in 2017 and a new version of the readout is currently under development which will enable the full speed data rate of the pixel detectors. Use of the radiation tolerant readout system can be envisioned for other beam instrumentation applications, which could provide new insight to beam diagnostics
An ultracold low emittance electron source
Ultracold atom-based electron sources have recently been proposed as an
alternative to the conventional photo-injectors or thermionic electron guns
widely used in modern particle accelerators. The advantages of ultracold
atom-based electron sources lie in the fact that the electrons extracted from
the plasma (created from near threshold photo-ionization of ultracold atoms)
have a very low temperature, i.e. down to tens of Kelvin. Extraction of these
electrons has the potential for producing very low emittance electron bunches.
These features are crucial for the next generation of particle accelerators,
including free electron lasers, plasma-based accelerators and future linear
colliders. The source also has many potential direct applications, including
ultrafast electron diffraction (UED) and electron microscopy, due to its
intrinsically high coherence. In this paper, the basic mechanism of ultracold
electron beam production is discussed and our new research facility for an
ultracold, low emittance electron source is introduced. This source is based on
a novel alternating current Magneto-Optical Trap (the AC-MOT). Detailed
simulations for a proposed extraction system have shown that for a 1 pC bunch
charge, a beam emittance of 0.35 mm mrad is obtainable, with a bunch length of
3 mm and energy spread 1 %.Comment: 15 pages, 9 figures, to be published in Journal of Instrumentation in
201
Antihydrogen studies in ALPHA
he ALPHA experiment studies antihydrogen as a means to investigate the symmetry of matter and antimatter. Spectroscopic studies of the anti-atom hold the promise of the most precise direct comparisons of matter and antimatter possible. ALPHA was the first to trap antihydrogen in a magnetic trap, allowing the first ever detection of atomic transitions in an anti-atom. More recently, through stochastic heating, we have also been able to put a new limit on the charge neutrality of antihydrogen. ALPHA is currently preparing to perform the first laser-spectroscopy of antihydrogen, hoping to excite the 2s state using a two-photon transition from the 1s state. We discuss the recent results as well as the key developments that led to these successes and discuss how we are preparing to perform the first laser-spectroscopy. We will also discuss plans to use our novel technique for gravitational tests on antihydrogen for a direct measurement of the sign of the gravitational force on antihydrogen
Antihydrogen formation dynamics in a multipolar neutral anti-atom trap
Antihydrogen production in a neutral atom trap formed by an octupole-based
magnetic field minimum is demonstrated using field-ionization of weakly bound
anti-atoms. Using our unique annihilation imaging detector, we correlate
antihydrogen detection by imaging and by field-ionization for the first time.
We further establish how field-ionization causes radial redistribution of the
antiprotons during antihydrogen formation and use this effect for the first
simultaneous measurements of strongly and weakly bound antihydrogen atoms.
Distinguishing between these provides critical information needed in the
process of optimizing for trappable antihydrogen. These observations are of
crucial importance to the ultimate goal of performing CPT tests involving
antihydrogen, which likely depends upon trapping the anti-atom
Centrifugal separation and equilibration dynamics in an electron-antiproton plasma
Charges in cold, multiple-species, non-neutral plasmas separate radially by
mass, forming centrifugally-separated states. Here, we report the first
detailed measurements of such states in an electron-antiproton plasma, and the
first observations of the separation dynamics in any centrifugally-separated
system. While the observed equilibrium states are expected and in agreement
with theory, the equilibration time is approximately constant over a wide range
of parameters, a surprising and as yet unexplained result. Electron-antiproton
plasmas play a crucial role in antihydrogen trapping experiments
- …