134 research outputs found
Recommended from our members
Proto-I axial-focusing experiments
The time-integrated axial (z) focus of the 4.5-cm-radius Proto I (1.5 MV, 500 kA) radial proton diode is presently limited to approx. 3 mm FWHM. This result is obtained with current neutralized beam transport in a gas cell with 6 Torr argon. If the vertical local divergence were the same (1/sup 0/ or less) as the horizontal divergence, the local divergence alone would produce a 1.5 mm FWHM focus. The axial focal size is evidently limited by time-dependent effects. These are studied by observing the beam incident upon various targets with two time-resolved pinhole cameras. The first camera observes Rutherford-scattered protons from gold targets with an array of 11 siicon PIN detectors. The second camera observes K/sub ..cap alpha../-fluorescence from aluminum targets with 4 independently-gated microchannel plates imaging tubes
Recommended from our members
Direct measurement of the energy spectrum of an intense proton beam
A time-resolved magnetic spectrometer has been used to measure the energy spectrum of an intense (0.5 TW/cm/sup 2/) proton beam. A thin (2400 A) gold foil placed at the focus of an ion diode Rutherford scattered protons by 90/sup 0/ into the spectrometer, reducing the beam intensity to a level suitable for magnetic analysis. The scattered beam was collimated by two 1 mm diameter apertures separated by 12.3 cm. The collimated protons were deflected in a 12.7 cm diameter, 6.65 Kg samarium-cobalt permanent magnet. The deflected protons were recorded simultaneously on CR-39 and eight 1 mm/sup 2/ by 35 ..mu..m thick PIN diodes. A Monte Carlo computer code was used to calculate the sensitivity and resolution of the spectrometer. Data taken on Proto-I show a 150 keV to 250 keV wide proton energy spectrum at each instant in time
Impaired leukocyte influx in cervix of postterm women not responding to prostaglandin priming
<p>Abstract</p> <p>Background</p> <p>Prolonged pregnancies are associated with increased rate of maternal and fetal complications. Post term women could be divided into at least two subgroups, one where parturition is possible to induce by prostaglandins and one where it is not. Our aim was to study parameters in cervical biopsies in women with spontaneous delivery at term (controls) and compare to those that are successfully induced post term (responders), and those that are not induced (non-responders), by local prostaglandin treatment.</p> <p>Methods</p> <p>Stromal parameters examined in this study were the accumulation of leukocytes (CD45, CD68), mRNAs and/or proteins for the extracellular matrix degrading enzymes (matrix metalloproteinase (MMP)-2, MMP-8 and MMP-9), their inhibitors (tissue inhibitor of MMP (TIMP)-1 and TIMP-2), interleukin-8 (IL-8), the platelet activating factor-receptor (PAF-R), syndecan-1 and estrogen binding receptors (estrogen receptor (ER)α, ERβ and G-coupled protein receptor (GPR) 30) as well as the proliferation marker Ki-67.</p> <p>Results</p> <p>The influx of leukocytes as assessed by CD45 was strongest in the responders, thereafter in the controls and significantly lower in the non-responders. IL-8, PAF-R and MMP-9, all predominantly expressed in leukocytes, showed significantly reduced immunostaining in the group of non-responders, while ERα and GPR30 were more abundant in the non-responders, as compared to the controls.</p> <p>Conclusion</p> <p>The impaired leukocyte influx, as reflected by the reduced number of CD45 positive cells as well as decreased immunostaining of IL-8, PAF-R and MMP-9 in the non-responders, could be one explanation of the failed ripening of the cervix in post term women. If the decreased leukocyte influx is a primary explanation to absent ripening or secondary, as a result of other factors, is yet to be established.</p
Recommended from our members
Radiative Properties of High Wire Number Tungsten Arrays with Implosion Times up to 250 ns
High wire number, 25-mm diameter tungsten wire arrays have been imploded on the 8-MA Saturn generator, operating in a long-pulse mode. By varying the mass load from 710 to 6140 ps/cm, implosion times of 130 to 250 ns have been obtained with implosion velocities of 50 to 25 cn-dys, respectively. These z-pinch implosions produced plasmas with millimeter diameters that radiated 600 to 800 kJ of x-rays, with powers of 20 to 49 TW; the corresponding pulse widths were 19 to 7.5 ns, with risetimes ranging from 6.5 to 4.0 ns. These powers and pulse widths are similar to those achieved with 50 ns implosion times on Saturn. Two-dimensional, radiation- magnetohydrodynamic calculations indicate that the imploding shells in these long implosion time experiments are comparable in width to those in the short pulse cases. This can only be due to lower initial perturbations. A heuristic wire array model suggests that the reduced perturbations, in the long pulse cases, may be due to the individual wire merger occurring well before the acceleration of the shell. The experiments and modeling suggest that 150 to 200 ns implosion time z-pinches could be employed for high-power, x-ray source applications
Radiative properties of high wire number tungsten arrays with implosion times up to 250 ns
High wire number, 25-mm diameter tungsten wire arrays have been imploded on the 8-MA Saturn generator, operating in a long-pulse mode. By varying the mass load from 710 to 6140 ps/cm, implosion times of 130 to 250 ns have been obtained with implosion velocities of 50 to 25 cn-dys, respectively. These z-pinch implosions produced plasmas with millimeter diameters that radiated 600 to 800 kJ of x-rays, with powers of 20 to 49 TW; the corresponding pulse widths were 19 to 7.5 ns, with risetimes ranging from 6.5 to 4.0 ns. These powers and pulse widths are similar to those achieved with 50 ns implosion times on Saturn. Two-dimensional, radiation- magnetohydrodynamic calculations indicate that the imploding shells in these long implosion time experiments are comparable in width to those in the short pulse cases. This can only be due to lower initial perturbations. A heuristic wire array model suggests that the reduced perturbations, in the long pulse cases, may be due to the individual wire merger occurring well before the acceleration of the shell. The experiments and modeling suggest that 150 to 200 ns implosion time z-pinches could be employed for high-power, x-ray source applications
Horizontal Branch Stars: The Interplay between Observations and Theory, and Insights into the Formation of the Galaxy
We review HB stars in a broad astrophysical context, including both variable
and non-variable stars. A reassessment of the Oosterhoff dichotomy is
presented, which provides unprecedented detail regarding its origin and
systematics. We show that the Oosterhoff dichotomy and the distribution of
globular clusters (GCs) in the HB morphology-metallicity plane both exclude,
with high statistical significance, the possibility that the Galactic halo may
have formed from the accretion of dwarf galaxies resembling present-day Milky
Way satellites such as Fornax, Sagittarius, and the LMC. A rediscussion of the
second-parameter problem is presented. A technique is proposed to estimate the
HB types of extragalactic GCs on the basis of integrated far-UV photometry. The
relationship between the absolute V magnitude of the HB at the RR Lyrae level
and metallicity, as obtained on the basis of trigonometric parallax
measurements for the star RR Lyrae, is also revisited, giving a distance
modulus to the LMC of (m-M)_0 = 18.44+/-0.11. RR Lyrae period change rates are
studied. Finally, the conductive opacities used in evolutionary calculations of
low-mass stars are investigated. [ABRIDGED]Comment: 56 pages, 22 figures. Invited review, to appear in Astrophysics and
Space Scienc
Recommended from our members
Development and Characterization of a Z-Pinch Driven Hohlraum High-Yield Inertial Confinement Fusion Target Concept
Increased ion temperature and neutron yield observed in magnetized indirectly driven D_{2}-filled capsule implosions on the national ignition facility
The application of an external 26 Tesla axial magnetic field to a D_{2} gas-filled capsule indirectly driven on the National Ignition Facility is observed to increase the ion temperature by 40% and the neutron yield by a factor of 3.2 in a hot spot with areal density and temperature approaching what is required for fusion ignition [1]. The improvements are determined from energy spectral measurements of the 2.45 MeV neutrons from the D(d,n)^{3}He reaction, and the compressed central core B field is estimated to be ∼4.9  kT using the 14.1 MeV secondary neutrons from the D(T,n)^{4}He reactions. The experiments use a 30 kV pulsed-power system to deliver a ∼3  μs current pulse to a solenoidal coil wrapped around a novel high-electrical-resistivity AuTa_{4} hohlraum. Radiation magnetohydrodynamic simulations are consistent with the experiment
- …