11 research outputs found

    Π‘Ρ€Π°Π²Π½ΠΈΡ‚Π΅Π»ΡŒΠ½Π°Ρ клиничСская ΠΎΡ†Π΅Π½ΠΊΠ° качСства ортопСдичСского лСчСния моляров CAD/CAM ΠΊΠΎΡ€ΠΎΠ½ΠΊΠ°ΠΌΠΈ ΠΌΠ΅Ρ‚ΠΎΠ΄ΠΈΠΊΠΎΠΉ chairside

    No full text
    The aim of the research was a comparative clinical evaluation of the results of prosthetic treatment with chairside CAD/CAM crowns for molars made from hybrid ceramics VITA Enamic, blocks of feldspatic ceramics VITABlocs Mark II, blocks of leucite glass IPS Empress CAD. Material and methods. The study involved 30 patients aged from 19 to 60 years old with defects in hard tissues of molars. For clinical evaluation we used Β«Clinical criteria for evaluation of direct and indirect restorationsΒ» developed by FDI in 2007, which included the assessment of several aesthetic, functional and biological parameters. We also included 2 additional criteria indicators: the condition of the antagonist tooth and the hygienic condition of the prosthesis in comparison with the hygiene of natural teeth. All patients were randomized into 3 groups of 10 people. After the treatment the clinical quality assessment was carried out in the following time intervals: 30 minutes, 1, 6, 12, 18, 24 months after the fixation of the crown. Results. Clinical evaluation of the results of prosthetic treatment of 30 patients with chairside CAD/CAM crowns made from three different materials did not reveal any significant difference in the clinical criteria for evaluation of direct and indirect restorations within 24 months.ЦСль исслСдования - ΡΡ€Π°Π²Π½ΠΈΡ‚Π΅Π»ΡŒΠ½Π°Ρ клиничСская ΠΎΡ†Π΅Π½ΠΊΠ° Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΎΠ² ортопСдичСского лСчСния Π±ΠΎΠ»ΡŒΠ½Ρ‹Ρ… с Π΄Π΅Ρ„Π΅ΠΊΡ‚Π°ΠΌΠΈ Ρ‚Π²Π΅Ρ€Π΄Ρ‹Ρ… Ρ‚ΠΊΠ°Π½Π΅ΠΉ моляров chairside CAD/CAM ΠΊΠΎΡ€ΠΎΠ½ΠΊΠ°ΠΌΠΈ ΠΈΠ· Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»ΠΎΠ². ΠœΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π» ΠΈ ΠΌΠ΅Ρ‚ΠΎΠ΄Ρ‹. Π’ исслСдовании участвовали 30 ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚ΠΎΠ² Π² возрастС ΠΎΡ‚ 19 Π΄ΠΎ 60 Π»Π΅Ρ‚ (18 ΠΌΡƒΠΆΡ‡ΠΈΠ½, 12 ΠΆΠ΅Π½Ρ‰ΠΈΠ½) с Π΄Π΅Ρ„Π΅ΠΊΡ‚Π°ΠΌΠΈ Ρ‚Π²Π΅Ρ€Π΄Ρ‹Ρ… Ρ‚ΠΊΠ°Π½Π΅ΠΉ моляров. Для исслСдования Π±Ρ‹Π»ΠΈ ΠΎΡ‚ΠΎΠ±Ρ€Π°Π½Ρ‹ Π±Π»ΠΎΠΊΠΈ ΠΈΠ· Π³ΠΈΠ±Ρ€ΠΈΠ΄Π½ΠΎΠΉ ΠΊΠ΅Ρ€Π°ΠΌΠΈΠΊΠΈ VITA Enamic, Π±Π»ΠΎΠΊΠΈ ΠΈΠ· ΠΏΠΎΠ»Π΅Π²ΠΎΡˆΠΏΠ°Ρ‚Π½ΠΎΠΉ ΠΊΠ΅Ρ€Π°ΠΌΠΈΠΊΠΈ VITABlocs Mark II, Π±Π»ΠΎΠΊΠΈ ΠΈΠ· Π»Π΅ΠΉΡ†ΠΈΡ‚Π½ΠΎΠΉ стСклокСрамики IPS Empress CAD, Ρ‚Π°ΠΊ ΠΊΠ°ΠΊ Π΄Π°Π½Π½Ρ‹Π΅ ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»Ρ‹ ΠΈΠΌΠ΅ΡŽΡ‚ Ρ€Π°Π·Ρ€Π΅ΡˆΠ΅Π½ΠΈΠ΅ ΠΊ ΠΏΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΡŽ Π½Π° Ρ‚Π΅Ρ€Ρ€ΠΈΡ‚ΠΎΡ€ΠΈΠΈ Π Π€. Для клиничСской ΠΎΡ†Π΅Π½ΠΊΠΈ качСства ортопСдичСского лСчСния ΠΌΡ‹ использовали Β«ΠšΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠΈΠ΅ ΠΊΡ€ΠΈΡ‚Π΅Ρ€ΠΈΠΈ ΠΎΡ†Π΅Π½ΠΊΠΈ прямых ΠΈ нСпрямых рСставраций», Ρ€Π°Π·Ρ€Π°Π±ΠΎΡ‚Π°Π½Π½Ρ‹Π΅ FDI Π² 2007 Π³., ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Π΅ Π²ΠΊΠ»ΡŽΡ‡Π°Π»ΠΈ ΠΎΡ†Π΅Π½ΠΊΡƒ Π½Π΅ΡΠΊΠΎΠ»ΡŒΠΊΠΈΡ… эстСтичСских, Ρ„ΡƒΠ½ΠΊΡ†ΠΈΠΎΠ½Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈ биологичСских ΠΏΠ°Ρ€Π°ΠΌΠ΅Ρ‚Ρ€ΠΎΠ². ΠœΡ‹ Ρ‚Π°ΠΊΠΆΠ΅ Π²ΠΊΠ»ΡŽΡ‡ΠΈΠ»ΠΈ 2 Π΄ΠΎΠΏΠΎΠ»Π½ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Ρ… ΠΊΡ€ΠΈΡ‚Π΅Ρ€ΠΈΠ°Π»ΡŒΠ½Ρ‹Ρ… показатСля: состояниС Π·ΡƒΠ±Π°-антагониста ΠΈ гигиСничСскоС состояниС ΠΏΡ€ΠΎΡ‚Π΅Π·Π° Π² сравнСнии с Π³ΠΈΠ³ΠΈΠ΅Π½ΠΎΠΉ СстСствСнных Π·ΡƒΠ±ΠΎΠ². ВсС ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚Ρ‹ Π±Ρ‹Π»ΠΈ Ρ€Π°Π½Π΄ΠΎΠΌΠΈΠ·ΠΈΡ€ΠΎΠ²Π°Π½Ρ‹ Π½Π° 3 Π³Ρ€ΡƒΠΏΠΏΡ‹ ΠΏΠΎ 10 Ρ‡Π΅Π»ΠΎΠ²Π΅ΠΊ. ПослС лСчСния клиничСская ΠΎΡ†Π΅Π½ΠΊΠ° качСства ΠΏΡ€ΠΎΠ²ΠΎΠ΄ΠΈΠ»Π°ΡΡŒ Π² ΡΠ»Π΅Π΄ΡƒΡŽΡ‰ΠΈΠ΅ Π²Ρ€Π΅ΠΌΠ΅Π½Π½Ρ‹Π΅ ΠΈΠ½Ρ‚Π΅Ρ€Π²Π°Π»Ρ‹: Ρ‡Π΅Ρ€Π΅Π· 30 ΠΌΠΈΠ½, 1, 6, 12, 18 ΠΈ 24 мСс послС фиксации ΠΊΠΎΡ€ΠΎΠ½ΠΊΠΈ. Π Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹. ΠšΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠ°Ρ ΠΎΡ†Π΅Π½ΠΊΠ° Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΎΠ² ортопСдичСского лСчСния 30 ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚ΠΎΠ² chairside CAD/CAM ΠΊΠΎΡ€ΠΎΠ½ΠΊΠ°ΠΌΠΈ Π½Π° моляры Π²Π΅Ρ€Ρ…Π½Π΅ΠΉ ΠΈ Π½ΠΈΠΆΠ½Π΅ΠΉ Ρ‡Π΅Π»ΡŽΡΡ‚Π΅ΠΉ, ΠΈΠ·Π³ΠΎΡ‚ΠΎΠ²Π»Π΅Π½Π½Ρ‹ΠΌΠΈ ΠΈΠ· Ρ‚Ρ€Π΅Ρ… Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… кСрамичСских ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»ΠΎΠ², Π½Π΅ выявила сущСствСнных Ρ€Π°Π·Π»ΠΈΡ‡ΠΈΠΉ ΠΏΠΎ Β«ΠšΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠΈΠΌ критСриям ΠΎΡ†Π΅Π½ΠΊΠΈ прямых ΠΈ нСпрямых рСставраций» Π² Ρ‚Π΅Ρ‡Π΅Π½ΠΈΠ΅ 24 мСс

    Comparative clinical evaluation of the prosthetic treatment quality of molars restored by chairside manufactured CAD/CAM crowns [Sravnitel'naia klinicheskaia otsenka kachestva ortopedicheskogo lecheniia moliarov CAD/CAM koronkami metodikoΔ­ chairside]

    No full text
    AIM: A comparative clinical evaluation of the results of prosthetic treatment with chairside CAD/CAM crowns for molars made from hybrid ceramics VITA Enamic, blocks of feldspatic ceramics VITABlocs Mark II, blocks of leucite glass IPS Empress CAD. MATERIAL AND METHODS: The study involved 30 patients aged from 19 to 60 years old with defects in hard tissues of molars. For clinical evaluation we used 'Clinical criteria for evaluation of direct and indirect restorations' developed by FDI in 2007, which included the assessment of several aesthetic, functional and biological parameters. We also included 2 additional criteria indicators: the condition of the antagonist tooth and the hygienic condition of the prosthesis in comparison with the hygiene of natural teeth. All patients were randomized into 3 groups of 10 people. After the treatment the clinical quality assessment was carried out in the following time intervals: 30 minutes, 1, 6, 12, 18, 24 months after the fixation of the crown. RESULTS: Clinical evaluation of the results of prosthetic treatment of 30 patients with chairside CAD/CAM crowns made from three different materials did not reveal any significant difference in the clinical criteria for evaluation of direct and indirect restorations within 24 months.ЦСль исслСдования - ΡΡ€Π°Π²Π½ΠΈΡ‚Π΅Π»ΡŒΠ½Π°Ρ клиничСская ΠΎΡ†Π΅Π½ΠΊΠ° Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΎΠ² ортопСдичСского лСчСния Π±ΠΎΠ»ΡŒΠ½Ρ‹Ρ… с Π΄Π΅Ρ„Π΅ΠΊΡ‚Π°ΠΌΠΈ Ρ‚Π²Π΅Ρ€Π΄Ρ‹Ρ… Ρ‚ΠΊΠ°Π½Π΅ΠΉ моляров chairside CAD/CAM ΠΊΠΎΡ€ΠΎΠ½ΠΊΠ°ΠΌΠΈ ΠΈΠ· Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»ΠΎΠ². ΠœΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π» ΠΈ ΠΌΠ΅Ρ‚ΠΎΠ΄Ρ‹. Π’ исслСдовании участвовали 30 ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚ΠΎΠ² Π² возрастС ΠΎΡ‚ 19 Π΄ΠΎ 60 Π»Π΅Ρ‚ (18 ΠΌΡƒΠΆΡ‡ΠΈΠ½, 12 ΠΆΠ΅Π½Ρ‰ΠΈΠ½) с Π΄Π΅Ρ„Π΅ΠΊΡ‚Π°ΠΌΠΈ Ρ‚Π²Π΅Ρ€Π΄Ρ‹Ρ… Ρ‚ΠΊΠ°Π½Π΅ΠΉ моляров. Для исслСдования Π±Ρ‹Π»ΠΈ ΠΎΡ‚ΠΎΠ±Ρ€Π°Π½Ρ‹ Π±Π»ΠΎΠΊΠΈ ΠΈΠ· Π³ΠΈΠ±Ρ€ΠΈΠ΄Π½ΠΎΠΉ ΠΊΠ΅Ρ€Π°ΠΌΠΈΠΊΠΈ VITA Enamic, Π±Π»ΠΎΠΊΠΈ ΠΈΠ· ΠΏΠΎΠ»Π΅Π²ΠΎΡˆΠΏΠ°Ρ‚Π½ΠΎΠΉ ΠΊΠ΅Ρ€Π°ΠΌΠΈΠΊΠΈ VITABlocs Mark II, Π±Π»ΠΎΠΊΠΈ ΠΈΠ· Π»Π΅ΠΉΡ†ΠΈΡ‚Π½ΠΎΠΉ стСклокСрамики IPS Empress CAD, Ρ‚Π°ΠΊ ΠΊΠ°ΠΊ Π΄Π°Π½Π½Ρ‹Π΅ ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»Ρ‹ ΠΈΠΌΠ΅ΡŽΡ‚ Ρ€Π°Π·Ρ€Π΅ΡˆΠ΅Π½ΠΈΠ΅ ΠΊ ΠΏΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΡŽ Π½Π° Ρ‚Π΅Ρ€Ρ€ΠΈΡ‚ΠΎΡ€ΠΈΠΈ Π Π€. Для клиничСской ΠΎΡ†Π΅Π½ΠΊΠΈ качСства ортопСдичСского лСчСния ΠΌΡ‹ использовали 'ΠšΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠΈΠ΅ ΠΊΡ€ΠΈΡ‚Π΅Ρ€ΠΈΠΈ ΠΎΡ†Π΅Π½ΠΊΠΈ прямых ΠΈ нСпрямых рСставраций', Ρ€Π°Π·Ρ€Π°Π±ΠΎΡ‚Π°Π½Π½Ρ‹Π΅ FDI Π² 2007 Π³., ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Π΅ Π²ΠΊΠ»ΡŽΡ‡Π°Π»ΠΈ ΠΎΡ†Π΅Π½ΠΊΡƒ Π½Π΅ΡΠΊΠΎΠ»ΡŒΠΊΠΈΡ… эстСтичСских, Ρ„ΡƒΠ½ΠΊΡ†ΠΈΠΎΠ½Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈ биологичСских ΠΏΠ°Ρ€Π°ΠΌΠ΅Ρ‚Ρ€ΠΎΠ². ΠœΡ‹ Ρ‚Π°ΠΊΠΆΠ΅ Π²ΠΊΠ»ΡŽΡ‡ΠΈΠ»ΠΈ 2 Π΄ΠΎΠΏΠΎΠ»Π½ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Ρ… ΠΊΡ€ΠΈΡ‚Π΅Ρ€ΠΈΠ°Π»ΡŒΠ½Ρ‹Ρ… показатСля: состояниС Π·ΡƒΠ±Π°-антагониста ΠΈ гигиСничСскоС состояниС ΠΏΡ€ΠΎΡ‚Π΅Π·Π° Π² сравнСнии с Π³ΠΈΠ³ΠΈΠ΅Π½ΠΎΠΉ СстСствСнных Π·ΡƒΠ±ΠΎΠ². ВсС ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚Ρ‹ Π±Ρ‹Π»ΠΈ Ρ€Π°Π½Π΄ΠΎΠΌΠΈΠ·ΠΈΡ€ΠΎΠ²Π°Π½Ρ‹ Π½Π° 3 Π³Ρ€ΡƒΠΏΠΏΡ‹ ΠΏΠΎ 10 Ρ‡Π΅Π»ΠΎΠ²Π΅ΠΊ. ПослС лСчСния клиничСская ΠΎΡ†Π΅Π½ΠΊΠ° качСства ΠΏΡ€ΠΎΠ²ΠΎΠ΄ΠΈΠ»Π°ΡΡŒ Π² ΡΠ»Π΅Π΄ΡƒΡŽΡ‰ΠΈΠ΅ Π²Ρ€Π΅ΠΌΠ΅Π½Π½Ρ‹Π΅ ΠΈΠ½Ρ‚Π΅Ρ€Π²Π°Π»Ρ‹: Ρ‡Π΅Ρ€Π΅Π· 30 ΠΌΠΈΠ½, 1, 6, 12, 18 ΠΈ 24 мСс послС фиксации ΠΊΠΎΡ€ΠΎΠ½ΠΊΠΈ. Π Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹. ΠšΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠ°Ρ ΠΎΡ†Π΅Π½ΠΊΠ° Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚ΠΎΠ² ортопСдичСского лСчСния 30 ΠΏΠ°Ρ†ΠΈΠ΅Π½Ρ‚ΠΎΠ² chairside CAD/CAM ΠΊΠΎΡ€ΠΎΠ½ΠΊΠ°ΠΌΠΈ Π½Π° моляры Π²Π΅Ρ€Ρ…Π½Π΅ΠΉ ΠΈ Π½ΠΈΠΆΠ½Π΅ΠΉ Ρ‡Π΅Π»ΡŽΡΡ‚Π΅ΠΉ, ΠΈΠ·Π³ΠΎΡ‚ΠΎΠ²Π»Π΅Π½Π½Ρ‹ΠΌΠΈ ΠΈΠ· Ρ‚Ρ€Π΅Ρ… Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹Ρ… кСрамичСских ΠΌΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π»ΠΎΠ², Π½Π΅ выявила сущСствСнных Ρ€Π°Π·Π»ΠΈΡ‡ΠΈΠΉ ΠΏΠΎ 'ΠšΠ»ΠΈΠ½ΠΈΡ‡Π΅ΡΠΊΠΈΠΌ критСриям ΠΎΡ†Π΅Π½ΠΊΠΈ прямых ΠΈ нСпрямых рСставраций' Π² Ρ‚Π΅Ρ‡Π΅Π½ΠΈΠ΅ 24 мСс

    Determining the spacecraft Foton M-4 attitude motion

    No full text
    Abstract: The paper presents the results of reconstruction of the spacecraft Foton M-4 attitude motion in the single-axis solar orientation mode. The reconstruction is based on processing the measurements of two vectors: the spacecraft angular rate and the strength of the Earth magnetic field. The processing technique uses kinematical equations of the attitude motion of a rigid body. In its framework, the measurement data of both types, collected on a time interval, are processed jointly. The angular rate data are interpolated by piecewise linear functions and those functions are substituted in kinematical equations for components of the quaternion, which defines a transformation of the spacecraft coupled coordinate system to the inertial one. The equations obtained present the kinematical model of a spacecraft attitude motion. The solution of the equations, which approximates the real motion, is found by the least squares method from the condition of the best agreement between measurement and calculation data of the magnetic strength. The technique allows to reconstruct the attitude motion on time intervals more than 10 hours. The found reconstructions are used for calculation of residual accelerations onboard the spacecraft.Note: Research direction:Theoretical and applied problems of mechanic

    Uncontrolled attitude motion of the prototype of the small spacecraft Aist

    No full text
    Abstract: We present the results of reconstruction of the uncontrolled attitude motion of the prototype of the small spacecraft Aist during its flight at the beginning of 2014. The reconstruction was realized by processing onboard measurements of the Earth magnetic field. The measurement data were accumulated in time segments, which had length about 100 min. The measurement data on each such segment were processed sim-ultaneously by means of the least squares method and integration of the spacecraft attitude motion equations. The estimates of the mathematical model parameters and initial conditions of the attitude motion were obtained as a result of such processing. The results of processing some segments above made clear the attitude motion of the spacecraft.Note: Research direction:Theoretical and applied problems of mechanic

    Determination of the spacecraft Aist attitude motion on measurements of the Earth magnetic field

    No full text
    Abstract: We present the results of reconstruction of the uncontrolled attitude motion of the small spacecraft Aist during its flight in May 2013. The reconstruction was realized by processing onboard measurements of the Earth magnetic field strength. The measurement data were accumulated in time segments, which had length about 100 min. The measurement data on each such segment were processed simultaneously by means of the least squares method and integration of the spacecraft attitude motion equations. The estimates of the mathematical model parameters and initial conditions of the attitude motion were obtained as a result of such processing. The results of processing some segments above made clear the attitude motion of the spacecraft.Note: Research direction:Theoretical and applied problems of mechanic

    Determining the small spacecraft Aist-2D attitude motion by measurements of the equipment KMU-1

    No full text
    Abstract: The paper presents the results of reconstruction of the spacecraft Aist-2D attitude motion in summer 2016. The reconstruction is based on processing the measurements of two vectors: the spacecraft angular rate and the strength of the Earth magnetic field. The processing technique uses kinematical equations of the attitude motion of a rigid body. In its framework, the measurement data of both types, collected on a time interval, are processed jointly. The angular rate data are interpolated by piecewise linear functions and those functions are substituted in kinematical equations for components of the quaternion, which defines a transformation of the spacecraft coupled coordinate system to the inertial one. The equations obtained present the kinematical model of a spacecraft attitude motion. The solution of the equations, which approximates the real motion, is found by the least squares method from the condition of the best agreement between measured and calculated data of the magnetic strength. The technique allows reconstructing the attitude motion on time intervals more than 10 hours.Note: Research direction:Theoretical and applied problems of mechanic

    Is it possible to improve neurodevelopmental abnormalities in Down syndrome?

    No full text
    corecore