3 research outputs found

    Elemental Mapping of Human Malignant Mesothelioma Tissue Samples Using High-Speed LA-ICP-TOFMS Imaging.

    Get PDF
    This is the first report of the use of laser ablation-inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOFMS) to analyze human malignant pleural mesothelioma (MPM) samples at the cellular level. MPM is an aggressive, incurable cancer associated with asbestos exposure, with a long latency and poor overall survival. Following careful optimization of the laser fluence, the simultaneous ablation of soft biological tissue and hard mineral fibers was possible, allowing the spatial detection of elements such as Si, Mg, Ca, and Fe, which are also present in the glass substrate. A low-dispersion LA setup was employed, which provided the high spatial resolution necessary to identify the asbestos fibers and fiber fragments in the tissue and to characterize the metallome at the cellular level (a pixel size of 2 μm), with a high speed (at 250 Hz). The multielement LA-ICP-TOFMS imaging approach enabled (i) the detection of asbestos fibers/mineral impurities within the MPM tissue samples of patients, (ii) the visualization of the tissue structure with the endogenous elemental pattern at high spatial resolution, and (iii) obtaining insights into the metallome of MPM patients with different pathologies in a single analysis run. Asbestos and other mineral fibers were detected in the lung and pleura tissue of MPM patients, respectively, based on their multielement pattern (Si, Mg, Ca, Fe, and Sr). Interestingly, strontium was detected in asbestos fibers, suggesting a link between this potential toxic element and MPM pathogenesis. Furthermore, monitoring the metallome around the talc deposit regions (characterized by elevated levels of Al, Mg, and Si) revealed significant tissue damage and inflammation caused by talc pleurodesis. LA-ICP-TOFMS results correlated to Perls' Prussian blue and histological staining of the corresponding serial sections. Ultimately, the ultra-high-speed and high-spatial-resolution capabilities of this novel LA-ICP-TOFMS setup may become an important clinical tool for simultaneous asbestos detection, metallome monitoring, and biomarker identification

    Needles in haystacks: using fast-response LA chambers and ICP-TOF-MS to identify asbestos fibres in malignant mesothelioma models

    Get PDF
    Malignant mesothelioma is an aggressive cancer associated with exposure to asbestos. Diagnosis of mesothelioma and other related lung diseases remains elusive due to difficulties surrounding identification and quantification of asbestos fibres in lung tissue. This article presents a laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) method to identify asbestos fibres in cellular models of mesothelioma. Use of a high-speed laser ablation system enabled rapid imaging of the samples with a lateral resolution of 3 μm, whilst use of a prototype time-of-flight ICP-MS provided pseudo-simultaneous detection of the elements between mass 23 (Na) and mass 238 (U). Three forms of asbestos fibre (actinolite, amosite and crocidolite) were distinguished from a non-asbestos control (wollastonite) based on their elemental profile, which demonstrated that LA-ICP-MS could be a viable technique for identification of asbestos fibres in clinical research samples

    Laser ablation inductively coupled plasma mass spectrometry as a novel clinical imaging tool to detect asbestos fibres in malignant mesothelioma.

    Get PDF
    RATIONALE: Malignant pleural mesothelioma is an extremely aggressive and incurable malignancy associated with prior exposure to asbestos fibres. Difficulties remain in relation to early diagnosis, notably due to impeded identification of asbestos in lung tissue. This study describes a novel laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) imaging approach to identify asbestos within mesothelioma models with clinical significance. METHODS: Human mesothelioma cells were exposed to different types of asbestos fibres and prepared on plastic slides for LA-ICP-MS analysis. No further sample preparation was required prior to analysis, which was performed using an NWR Image 266nm laser ablation system coupled to an Element XR sector-field ICP mass spectrometer, with a lateral resolution of 2 μm. Data was processed using LA-ICP-MS ImageTool v1.7 with the final graphic production made using DPlot Software. RESULTS: Four different mineral fibres were successfully identified within the mesothelioma samples based on some of the most abundant elements that make up these fibres (Si, Mg and Fe). Using LA-ICP-MS as an imaging tool provided information on the spatial distribution of the fibres at cellular level, which is essential in asbestos detection within tissue samples. Based on the metal counts generated by the different types of asbestos, different fibres can be identified based on shape, size, and elemental composition. Detection of Ca was attempted but requires further optimisation. CONCLUSION: Asbestos fibres detection in the lung tissues is very useful, if not necessary, to complete the pathological diagnosis of asbestos-related malignancies in medicolegal field. For the first time, this study demonstrates the successful application of LA-ICP-MS imaging to identify asbestos fibres and other mineral fibres within mesothelioma samples. Ultimately, high-resolution, fast-speed LA-ICP-MS analysis has the potential to be integrated into clinical workflow to aid earlier detection and stratification of mesothelioma patient samples
    corecore