1 research outputs found
INTERACTION OF FEMTOSECOND LASER RADIATION WITH SKIN: MATHEMATICAL MODEL
The features of human skin response to the impact of femtosecond laser radiation were researched. The Monte–Carlo method was used for estimation of the radiation penetration depth into the skin cover. We used prevalent wavelength equal to 800 nm (for Ti: sapphire laser femtosecond systems). A mathematical model of heat transfer process was introduced based on the
analytical solution of the system of equations describing the dynamics of the electron and phonon subsystems. An experiment
was carried out to determine the threshold energy of biological tissue injury (chicken skin was used as a test object). The
value of electronic subsystem relaxation time was determined from the experiment and is in keeping with literature data. The
results of this work can be used to assess the maximum permissible exposure of laser radiation of different lengths that cause the damage of biological tissues, as well as for the formation of safe operation standards for femtosecond laser systems