4 research outputs found

    The anterolateral ligament of the knee: unwrapping the enigma. Anatomical study and comparison to previous reports.

    Get PDF
    It has been suggested that the anterolateral ligament (ALL) of the knee may have importance in limiting rotational instability, and reconstruction may prevent a continued pivot-shift following anterior cruciate ligament surgery. However, the anatomy of this ligament has not been consistently reported in recent publications. We describe our experience of cadaveric dissection with reference to other published work.This article is freely available via Open Access. Click on the 'Additional Link' above to access the full-text from the publisher's site.Published (Open Access

    Personalised high tibial osteotomy has mechanical safety equivalent to generic device in a case–control in silico clinical trial

    Get PDF
    Background Despite favourable outcomes relatively few surgeons offer high tibial osteotomy (HTO) as a treatment option for early knee osteoarthritis, mainly due to the difficulty of achieving planned correction and reported soft tissue irritation around the plate used to stablise the osteotomy. To compare the mechanical safety of a new personalised 3D printed high tibial osteotomy (HTO) device, created to overcome these issues, with an existing generic device, a case-control in silico virtual clinical trial was conducted. Methods Twenty-eight knee osteoarthritis patients underwent computed tomography (CT) scanning to create a virtual cohort; the cohort was duplicated to form two arms, Generic and Personalised, on which virtual HTO was performed. Finite element analysis was performed to calculate the stresses in the plates arising from simulated physiological activities at three healing stages. The odds ratio indicative of the relative risk of fatigue failure of the HTO plates between the personalised and generic arms was obtained from a multi-level logistic model. Results Here we show, at 12 weeks post-surgery, the odds ratio indicative of the relative risk of fatigue failure was 0.14 (95%CI 0.01 to 2.73, pÂż=Âż0.20). Conclusions This novel (to the best of our knowledge) in silico trial, comparing the mechanical safety of a new personalised 3D printed high tibial osteotomy device with an existing generic device, shows that there is no increased risk of failure for the new personalised design compared to the existing generic commonly used device. Personalised high tibial osteotomy can overcome the main technical barriers for this type of surgery, our findings support the case for using this technology for treating early knee osteoarthritis.Postprint (published version

    Characterization of the anatomy of the anterolateral ligament of the knee using magnetic resonance imaging

    No full text
    OBJECTIVE: The anterolateral ligament (ALL) may limit tibial internal rotation and pivot-shift following anterior cruciate ligament reconstruction. Previous studies, using magnetic resonance imaging (MRI) to identify this structure, have been inconsistent. We aimed to further characterize the anatomy of this ligament with reference to previous work. MATERIALS AND METHODS: Institutional Review Board approval was gained and a retrospective study of 154 consecutive 1.5-T MRI studies was performed by a consultant musculoskeletal radiologist. Cases with a lateral compartment or cruciate injury and patients under 16 years were excluded. A total of 100 MRIs (98 patients; 63 males: 35 females; mean age, 45.3 years, range, 16-85 years) were included in the study. RESULTS: The ALL was visualized partially in 94 (94.0 %) of the cases and fully with distinct femoral and tibial fibers in 57 (57.0 %) of the cases. Although the femoral origin was discreet in only 57 (57.0 %) of cases, the tibial insertion (7.64 +/- 1.26 mm below the joint-line) and meniscal attachment were demonstrated in all cases where the ligament was seen. Where the femoral origin was not seen, a broad expansion of the ligament was noted. We identified four types of meniscal attachment (complete, central, bipolar, and inferior-only). The thickness of the ALL, at the level of the joint-line, was 1.75 +/- 0.57 mm. CONCLUSIONS: The ALL is a consistent structure with meniscal and tibial portions identifiable in the majority of MRI studies of the uninjured knee. There is an attachment to the lateral meniscus with anatomical variation described by our subclassification

    Tibial tubercle osteotomy for patello-femoral joint disorders.

    No full text
    Tibial tubercle osteotomy has a long history in the management of patella instability and patello-femoral arthritis. This review aims to provide a comprehensive review of the literature describing the biomechanics of the patello-femoral joint and the rationale behind the use of the tibial tubercle osteotomy in modern day practice. Several different tibial tubercle osteotomies are available and we aim to detail the concepts behind their use and the subsequent clinical results. With continued developments of chondrocyte implantation techniques, the potential to fill defects on the chondral surface of either the patella or trochlea in conjunction with a tibial tubercle osteotomy may well become more commonplace in a group that is commonly young and difficult to manage. Level of evidence III.Accepted manuscript (12 month embargo
    corecore