8,252 research outputs found
Non-compensation of an Electromagnetic Compartment of a Combined Calorimeter
The method of extraction of the ratio, the degree of non-compensation,
of the electromagnetic compartment of the combined calorimeter is suggested.
The ratio of has been determined on the basis of the 1996
combined calorimeter test beam data. This value agrees with the prediction that
for this electromagnetic calorimeter.Comment: LATEX, 17 pages, 7 figure
Longitudinal Hadronic Shower Development in a Combined Calorimeter
This work is devoted to the experimental study of the longitudinal hadronic
shower development in the ATLAS barrel combined prototype calorimeter
consisting of the lead-liquid argon electromagnetic part and the
iron-scintillator hadronic part. The results have been obtained on the basis of
the 1996 combined test beam data which have been taken on the H8 beam of the
CERN SPS, with the pion beams of 10, 20, 40, 50, 80, 100, 150 and 300 GeV/c.
The degree of description of generally accepted Bock parameterization of the
longitudinal shower development has been investigated. It is shown that this
parameterization does not give satisfactory description for this combined
calorimeter. Some modification of this parameterization, in which the e/h
ratios of the compartments of the combined calorimeter are used, is suggested
and compared with the experimental data. The agreement between such
parameterization and the experimental data is demonstrated.Comment: Latex, 21 pages, 10 figure
Self-Stimulated Undulator Radiation and its Possible Applications
We investigated the phenomena of self-stimulation of incoherent emission from
an undulator installed in the linear accelerator or quasi-isochronous storage
ring. We discuss possible applications of these phenomena for the beam physics
also.Comment: 14 pages, 4 figure
The e/h Method of Energy Reconstruction for Combined Calorimeter
The new simple method of the energy reconstruction for a combined calorimeter, which we called the e/h method, is suggested. It uses only the known e/h ratios and the electron calibration constants and does not require the determination of any parameters by a minimization technique. The method has been tested on the basis of the 1996 test beam data of the combined calorimeter and demonstrated the correctness of the reconstruction of the mean values of energies. The obtained fractional energy resolution is . This algorithm can be used for the fast energy reconstruction in the first level trigger
- …