25 research outputs found

    Weak D prevalence among Indian blood donors

    No full text

    Perioperative use of allogenic blood components in live-related donor orthotopic liver transplantation: A cross sectional study

    No full text
    Background: In spite of many improvements that have reduced the blood component requirements, substantial numbers of transfusions are still needed in liver transplantation. Aims: The objective of the present study was to analyze the perioperative usage of allogenic blood components and predict the preoperative factors as predictors of red cell transfusion in live-related donor liver transplant recipients. Materials and Methods: The retrospective data on utilization of allogenic blood components were analyzed for a total of 150 liver transplant procedures. The data on utilization of blood components during surgery and till 48 hours of ICU stay was collected from the blood bank record and hospital information system (HIS). Results: Red cell concentrate was commonest blood component used in liver transplant recipient and most of the transfusion took place during surgery. During intraoperative period 92.7% (N = 139) of the cases utilized red cell components with the median number of five whereas in postoperative period only 38% (N = 57) of patients received blood with the median number of one. This study demonstrates that the preoperative hemoglobin and platelet count are the predictors of utilization of red cell concentrates during surgery. There were a total of 11 (7.3%) recipients who didn′t receive allogeneic blood transfusion in any form.Utilization of blood components was negligible among organ donors. Conclusion: Our study demonstrates the pattern and predictors of usage of allogeneic blood components in liver transplant recipients at a tertiary healthcare center in India

    First Indian study to establish safety of immediate-spin crossmatch for red blood cell transfusion in antibody screen-negative recipients

    No full text
    Background and Objectives: The US Food and Drug Administration and American Association of Blood Banks approved the type and screen approach in 1980s, long after antibody screen (AS) was introduced in 1950s. The present study omits conventional anti-human globulin (AHG) crossmatch and replaces it with immediate-spin (IS) crossmatch as part of pretransfusion testing in AS-negative patients to study the safety and effectiveness of IS crossmatch in recipients. Materials and Methods: This prospective longitudinal study was conducted on over 5000 red cell units transfused to AS-negative patients admitted to the hospital. Pretransfusion testing comprised blood grouping and AS followed by IS crossmatch, at the time of issue of red cell unit. The patients were transfused IS compatible red cell units. AHG crossmatch was performed posttransfusion for all red cell units. Any incompatible AHG crossmatch was followed up as suspected transfusion reaction. Results: A total of 5023 red cell units were transfused to 2402 patients with negative AS. 99.7% IS compatible red cell units were also compatible on posttransfusion AHG crossmatch. Anti-P1 alloantibody was identified in one patient who was transfused two IS crossmatch compatible units but later both units were incompatible on AHG crossmatch. There was no clinical or serological sign of hemolysis in the patient. Conclusion: In AS-negative patients, IS crossmatch is as safe as conventional AHG crossmatch and can, therefore, replace conventional AHG crossmatch protocol

    Expression of CD71 by flow cytometry in acute leukemias: More often seen in acute myeloid leukemia

    No full text
    Background: CD71 is a marker that has been usually used for identifying dysplasia in the erythroid series. We have tried to evaluate the expression of CD71 in various types of acute leukemias. Materials and Methods: We studied 48 patients of acute leukemia, of which 25 were acute myeloid leukemia (AML), 13 were precursor B-acute lymphoblastic leukemia (B-ALL), 8 were T-ALL, and 2 were mixed phenotype acute leukemia (T/myeloid) as per the WHO classification. Results: We found that the expression of CD71 was most prevalent in AMLs (84%), followed by T-ALL (50%) and least in B-ALL (30%). Conclusion: This finding clearly shows the higher expression of CD71 in AMLs compared to other common type of leukemias, such as B- and T-ALL. We suggest that the high expression of CD71 in AMLs could be used as a diagnostic marker and may also be used for minimal residual disease analysis after further studies in posttreatment scenario. This study is the first of its kind in the South Asian population

    Evaluation of the red cell hemolysis in packed red cells during processing and storage

    No full text
    Introduction : Storage of red cells causes a progressive increase in hemolysis. In spite of the use of additive solutions for storage and filters for leucoreduction, some amount of hemolysis is still inevitable. The extent of hemolysis, however, should not exceed the permissible threshold for hemolysis even on the 42 nd day of storage. Study Design and Methods: Eighty units of packed red cells, 40 stored in SAGM post leucoreduction and 40 in ADSOL without leucoreduction filters, were evaluated for plasma hemoglobin by HemoCue Plasma Hemoglobin analyzer on the day of collection and on the 7 th , 14 th , 21 st , 28 th , 35 th and 42 nd days thereafter. The hemoglobin and hematocrit were also noted for all these units by the Beckman and Coulter analyzer. Percentage hemolysis was then calculated. Observations: Hemolysis progressively increased with the storage period in all the stored red cell units (SAGM as well ADSOL). However, on day 42 nd of storage, free hemoglobin in all the red cell units was within the permissible level (which is 0.8% according to the Council of Europe guidelines and 1% as per the US FDA guidelines). The mean percentage hemolysis was slightly higher in the SAGM-containing bags with an integral leucoreduction filter as compared to the bags containing ADSOL. However this difference was marginal and not statistically significant. Conclusion: Hemolysis of the red cells increases with storage. However, maximum hemolysis does not exceed the permissible limits at any time thereby indicating the effect of optimum processing and storage conditions on red cell hemolysis

    Evaluation of a new serological test for syphilis based on chemiluminescence assay in a tertiary care hospital

    No full text
    Context: Syphilis is a transfusion transmissible infections and it is mandatory to do serological test for syphilis (STS) on all donor blood samples. STS is usually based on detection of antibodies against the cardiolipin-lecithin antigen or against the Treponema-specific antigen. STS with good sensitivity and specificity helps enhance blood safety and consolidation of STS along with other transfusion transmittable infections such as human immunodeficiency virus, hepatitis-C virus, and hepatitis-B virus helps in reducing the errors and enhances efficiency. Aims: This study was designed to evaluate the performance of newly introduced VITROS ® syphilis Treponema pallidum agglutination (TPA) assay based on enhanced chemiluminescence principle for its analytical performance for use as a STS on donor blood samples at a tertiary care health center in National Capital Region, India. Materials and Methods: A total of 108 random blood units collected from the donors (both voluntary and replacement donors) and 28 known syphilis sero-reactive samples stored at −20°C, were used to evaluate the performance of VITROS ® syphilis TPA assay based on enhanced chemiluminescence assay on VITROS ® ECiQ immunodiagnostics system along with its analytical performance in terms of its sensitivity, precision, cross-reactivity and interference studies. Results: VITROS ® syphilis TPA showed 100% sensitivity and specificity with precision (20 days study) of <10% co-efficient of variation. There was no cross-reactivity with other viral and auto-immune antibodies. No interference was observed from endogenous interfering substances like free hemoglobin or fats. Conclusions: Performance of the VITROS ® syphilis TPA assay meets the requirements for its use as STS in blood bank, thus allowing consolidation with other transfusion transmittable infections screening assay on chemiluminescence platform, which is highly valuable for optimizing workflow and efficiency

    New cost-effective human leukocyte antigen testing algorithm for screening of human leukocyte antigen-matched related donor in thalassemia major patient pretransplant workup: A single-center study from resource-constrained settings

    No full text
    Introduction: India has a huge disease burden of thalassemia major with an estimated 40 million carriers and over a million thalassemia major patients. Very few patients are optimally treated, and the standard of care “hematopoietic stem cell transplant” (HSCT) is out of reach for most patients and their families. The cost of HSCT is significant, and a substantial proportion of it goes to human leukocyte antigen (HLA) testing of family members (HLA screening) in hope of getting a matched related donor (MRD) for HSCT. The aim of this study was to establish that a new proposed testing algorithm of HLA typing would be more cost-effective as compared to the conventional HLA screening within MRD families for possible HSCT. Material and Methods: Buccal swab samples of 177 thalassemia patients and their prospective family donors (232) were collected. Using a new HLA testing algorithm, samples were tested for HLA typing in a sequential manner (first HLA-B, then HLA-A, and finally HLA-DR) using the sequence-specific oligonucleotide probe method on the Luminex platform. Results: The new sequential HLA-A, HLA-B, and HLA-DRB1 testing algorithm showed a 49.1% reduction in cost compared to the conventional HLA testing algorithm. Furthermore, 40 patients (22.59%) were found to have HLA-MRD within the family among other samples that were tested. Conclusion: The new HLA testing algorithm proposed in the present study for identifying MRD for HSCT resulted in a substantial reduction in the cost of HSCT workup

    Autologous peripheral blood stem cell harvest: Collection efficiency and factors affecting it

    No full text
    Background: Harvest of hematopoietic progenitor cells via leukapheresis is being used increasingly for transplants in India. Adequate yield of cells per kilogram body weight of recipient is required for successful engraftment. Collection efficiency (CE) is an objective quality parameter used to assess the quality of leukapheresis program. In this study, we calculated the CE of the ComTec cell separator (Fresenius Kabi, Germany) using two different formulae (CE1 and CE2) and analyzed various patient and procedural factors, which may affect it. Materials and Methods: One hundred and one consecutive procedures in 77 autologous donors carried out over 3 years period were retrospectively reviewed. Various characteristics like gender, age, weight, disease status, hematocrit, preprocedure total leukocyte count, preprocedure CD34 positive (CD34+) cells count, preprocedure absolute CD34+ cell count and processed apheresis volume effect on CE were compared. CE for each procedure was calculated using two different formulae, and results were compared using statistical correlation and regression analysis. Results: The mean CE1 and CE2 was 41.2 and 49.1, respectively. CE2 appeared to be more accurate indicator of overall CE as it considered the impact of continued mobilization of stem cells during apheresis procedure, itself. Of all the factors affecting CE, preprocedure absolute CD34+ was the only independent factor affecting CE. Conclusion: The only factor affecting CE was preprocedure absolute CD34+ cells. Though the mean CE2 was higher than CE1, it was not statistically significant
    corecore