7 research outputs found

    Photoelectric properties of tl1-xin1-xbxse2 (b=si, sn, ge; x=0.1, 0.2-0.25) alloys

    No full text
    Photoelectric Properties of Tl1-xIn1-xBxSe2 (B=Si, Sn, Ge; x=0.1, 0.2-0.25) Alloy

    The experimental evidence of a strong coupling regime in the hybrid Tamm plasmon-surface plasmon polariton mode

    No full text
    Total internal reflection ellipsometry was employed for the excitation and study of hybrid Tamm plasmon-surface plasmon polaritons mode. Simple optical methodology using optical filters to cut the part of incident light spectra was proposed. Using optical filters measured energy spectra was divided into two parts where in each range only one branch of the hybrid TPP-SPP plasmonic mode was excited directly by the incident light. Present experimental studies have shown, that if the investigated system is in strong coupling, this is always enough to excite only one component of the hybrid excitation. Thus, its dispersion relation will be the same as when the excitation is done with a whole spectrum. In the case of the TPP-SPP hybrid mode where strong coupling is realized only in p-polarized light, the fitting results have shown that the strongest coupling was at the point where the noninteracting TPP and SPP curves should be crossing. The obtained Rabi splitting for the hybrid TPP and SPP modes in BK7 prism/1D PC TiO2/SiO2 (60 nm/110 nm)/TiO2 (30 nm)/Au (40 nm) multilayered structure was about 105 meV

    Increase of the photoconductivity quantum yield in silicon irradiated by neutrons to extremely high fluences

    No full text
    An enhanced quantum yield observed in silicon ionizing radiation detectors, neutron-irradiated to extremely high fluences, could be attributed to impact ionization via deep levels. The quantum yield was investigated by the intrinsic photoconductivity optical spectroscopy in silicon irradiated by neutrons to a wide range of fluences up to 1×10171 \times 10^{17} neutron cm2^{-2}. An increase of quantum yield was observed in highly irradiated samples. We have demonstrated that the quantum yield enhancement could be attributed to the impact ionization via deep levels, this process being presumably related to disordered defect clusters regions in Si. The proposed mechanism explains the observed decrease of the impact ionization energy by at least an order of magnitude at low temperature. The impact ionization energy values of up to 0.30–0.36 eV and less, and 0.38–0.40 eV were determined at T ∼ 21–33 K and at T = 195 K, respectively

    The Application of a CMR-B-Scalar Sensor for the Investigation of the Electromagnetic Acceleration of Type II Superconductors

    No full text
    In this paper, we investigated the behavior of a type II superconducting armature when accelerated by a pulsed magnetic field generated by a single-stage pancake coil. While conducting this investigation, we performed a numerical finite element simulation and an experimental study of the magnetic field dynamics at the edge of the pancake coil when the payload was a superconducting disc made from YBa2Cu3O7−x, cooled down to 77 K. The magnetic field measurements were performed using a CMR-B-scalar sensor, which was able to measure the absolute magnitude of the magnetic field and was specifically manufactured in order to increase the sensor’s sensitivity up to 500 mT. It was obtained that type II superconducting armatures can outperform normal metals when the launch conditions are tailored to their electromagnetic properties.This article belongs to the Special Issue Magnetic Sensors and Systems for Scientific and Industrial Application

    The Application of a CMR-B-Scalar Sensor for the Investigation of the Electromagnetic Acceleration of Type II Superconductors

    No full text
    In this paper, we investigated the behavior of a type II superconducting armature when accelerated by a pulsed magnetic field generated by a single-stage pancake coil. While conducting this investigation, we performed a numerical finite element simulation and an experimental study of the magnetic field dynamics at the edge of the pancake coil when the payload was a superconducting disc made from YBa2Cu3O7−x, cooled down to 77 K. The magnetic field measurements were performed using a CMR-B-scalar sensor, which was able to measure the absolute magnitude of the magnetic field and was specifically manufactured in order to increase the sensor’s sensitivity up to 500 mT. It was obtained that type II superconducting armatures can outperform normal metals when the launch conditions are tailored to their electromagnetic properties

    Revealing the SARS-CoV-2 spike protein and specific antibody immune complex formation mechanism for precise evaluation of antibody affinity

    No full text
    The profound understanding and detailed evaluation of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike (SCoV2-S) protein and specific antibody interaction mechanism is of high importance in the development of immunosensors for COVID-19. In the present work, we studied a model system of immobilized SCoV2-S protein and specific monoclonal antibodies by molecular dynamics of immune complex formation in real time. We simultaneously applied spectroscopic ellipsometry and quartz crystal microbalance with dissipation to reveal the features and steps of the immune complex formation. We showed direct experimental evidence based on acoustic and optical measurements that the immune complex between covalently immobilized SCoV2-S and specific monoclonal antibodies is formed in two stages. Based on these findings it was demonstrated that applying a two-step binding mathematical model for kinetics analysis leads to a more precise determination of interaction rate constants than that determined by the 1:1 Langmuir binding model. Our investigation showed that the equilibrium dissociation constants (KD) determined by a two-step binding model and the 1:1 Langmuir model could differ significantly. The reported findings can facilitate a deeper understanding of antigen–antibody immune complex formation steps and can open a new way for the evaluation of antibody affinity towards corresponding antigens

    Measurement System for Short-Pulsed Magnetic Fields

    No full text
    A measurement system based on the colossal magnetoresistance CMR-B-scalar sensor was developed for the measurement of short-duration high-amplitude magnetic fields. The system consists of a magnetic field sensor made from thin nanostructured manganite film with minimized memory effect, and a magnetic field recording module. The memory effect of the La1−xSrx(Mn1−yCoy)zO3 manganite films doped with different amounts of Co and Mn was investigated by measuring the magnetoresistance (MR) and resistance relaxation in pulsed magnetic fields up to 20 T in the temperature range of 80–365 K. It was found that for low-temperature applications, films doped with Co (LSMCO) are preferable due to the minimized magnetic memory effect at these temperatures, compared with LSMO films without Co. For applications at temperatures higher than room temperature, nanostructured manganite LSMO films with increased Mn content above the stoichiometric level have to be used. These films do not exhibit magnetic memory effects and have higher MR values. To avoid parasitic signal due to electromotive forces appearing in the transmission line of the sensor during measurement of short-pulsed magnetic fields, a bipolar-pulsed voltage supply for the sensor was used. For signal recording, a measurement module consisting of a pulsed voltage generator with a frequency up to 12.5 MHz, a 16-bit ADC with a sampling rate of 25 MHz, and a microprocessor was proposed. The circuit of the measurement module was shielded against low- and high-frequency electromagnetic noise, and the recorded signal was transmitted to a personal computer using a fiber optic link. The system was tested using magnetic field generators, generating magnetic fields with pulse durations ranging from 3 to 20 μs. The developed magnetic field measurement system can be used for the measurement of high-pulsed magnetic fields with pulse durations in the order of microseconds in different fields of science and industry
    corecore