829 research outputs found
Full-wave calculation of reflection coefficients from D-region electron-density profiles
Full-wave calculations of VLF reflection coefficients from D region electron density profile
FACT -- the First Cherenkov Telescope using a G-APD Camera for TeV Gamma-ray Astronomy (HEAD 2010)
Geiger-mode Avalanche Photodiodes (G-APD) bear the potential to significantly
improve the sensitivity of Imaging Air Cherenkov Telescopes (IACT). We are
currently building the First G-APD Cherenkov Telescope (FACT) by refurbishing
an old IACT with a mirror area of 9.5 square meters and construct a new, fine
pixelized camera using novel G-APDs. The main goal is to evaluate the
performance of a complete system by observing very high energy gamma-rays from
the Crab Nebula. This is an important field test to check the feasibility of
G-APD-based cameras to replace at some time the PMT-based cameras of planned
future IACTs like AGIS and CTA. In this article, we present the basic design of
such a camera as well as some important details to be taken into account.Comment: Poster shown at HEAD 2010, Big Island, Hawaii, March 1-4, 201
A novel camera type for very high energy gamma-ray astronomy based on Geiger-mode avalanche photodiodes
Geiger-mode avalanche photodiodes (G-APD) are promising new sensors for light
detection in atmospheric Cherenkov telescopes. In this paper, the design and
commissioning of a 36-pixel G-APD prototype camera is presented. The data
acquisition is based on the Domino Ring Sampling (DRS2) chip. A sub-nanosecond
time resolution has been achieved. Cosmic-ray induced air showers have been
recorded using an imaging mirror setup, in a self-triggered mode. This is the
first time that such measurements have been carried out with a complete G-APD
camera.Comment: 9 pages with 11 figure
FACT -- The G-APD revolution in Cherenkov astronomy
Since two years, the FACT telescope is operating on the Canary Island of La
Palma. Apart from its purpose to serve as a monitoring facility for the
brightest TeV blazars, it was built as a major step to establish solid state
photon counters as detectors in Cherenkov astronomy. The camera of the First
G-APD Cherenkov Telesope comprises 1440 Geiger-mode avalanche photo diodes
(G-APD), equipped with solid light guides to increase the effective light
collection area of each sensor. Since no sense-line is available, a special
challenge is to keep the applied voltage stable although the current drawn by
the G-APD depends on the flux of night-sky background photons significantly
varying with ambient light conditions. Methods have been developed to keep the
temperature and voltage dependent response of the G-APDs stable during
operation. As a cross-check, dark count spectra with high statistics have been
taken under different environmental conditions. In this presentation, the
project, the developed methods and the experience from two years of operation
of the first G-APD based camera in Cherenkov astronomy under changing
environmental conditions will be presented.Comment: Proceedings of the Nuclear Science Symposium and Medical Imaging
Conference (IEEE-NSS/MIC), 201
Mechanical Translation
Contains reports on twelve research projects.National Science Foundatio
FACT - The First G-APD Cherenkov Telescope: Status and Results
The First G-APD Cherenkov telescope (FACT) is the first telescope using
silicon photon detectors (G-APD aka. SiPM). It is built on the mount of the
HEGRA CT3 telescope, still located at the Observatorio del Roque de los
Muchachos, and it is successfully in operation since Oct. 2011. The use of
Silicon devices promises a higher photon detection efficiency, more robustness
and higher precision than photo-multiplier tubes. The FACT collaboration is
investigating with which precision these devices can be operated on the
long-term. Currently, the telescope is successfully operated from remote and
robotic operation is under development. During the past months of operation,
the foreseen monitoring program of the brightest known TeV blazars has been
carried out, and first physics results have been obtained including a strong
flare of Mrk501. An instantaneous flare alert system is already in a testing
phase. This presentation will give an overview of the project and summarize its
goals, status and first results
Cauchy's infinitesimals, his sum theorem, and foundational paradigms
Cauchy's sum theorem is a prototype of what is today a basic result on the
convergence of a series of functions in undergraduate analysis. We seek to
interpret Cauchy's proof, and discuss the related epistemological questions
involved in comparing distinct interpretive paradigms. Cauchy's proof is often
interpreted in the modern framework of a Weierstrassian paradigm. We analyze
Cauchy's proof closely and show that it finds closer proxies in a different
modern framework.
Keywords: Cauchy's infinitesimal; sum theorem; quantifier alternation;
uniform convergence; foundational paradigms.Comment: 42 pages; to appear in Foundations of Scienc
Isotopic Composition of Light Nuclei in Cosmic Rays: Results from AMS-01
The variety of isotopes in cosmic rays allows us to study different aspects
of the processes that cosmic rays undergo between the time they are produced
and the time of their arrival in the heliosphere. In this paper we present
measurements of the isotopic ratios 2H/4He, 3He/4He, 6Li/7Li, 7Be/(9Be+10Be)
and 10B/11B in the range 0.2-1.4 GeV of kinetic energy per nucleon. The
measurements are based on the data collected by the Alpha Magnetic
Spectrometer, AMS-01, during the STS-91 flight in 1998 June.Comment: To appear in ApJ. 12 pages, 11 figures, 6 table
Search for Branons at LEP
We search, in the context of extra-dimension scenarios, for the possible
existence of brane fluctuations, called branons. Events with a single photon or
a single Z-boson and missing energy and momentum collected with the L3 detector
in e^+ e^- collisions at centre-of-mass energies sqrt{s}=189-209$ GeV are
analysed. No excess over the Standard Model expectations is found and a lower
limit at 95% confidence level of 103 GeV is derived for the mass of branons,
for a scenario with small brane tensions. Alternatively, under the assumption
of a light branon, brane tensions below 180 GeV are excluded
Search for Charginos with a Small Mass Difference with the Lightest Supersymmetric Particle at \sqrt{s} = 189 GeV
A search for charginos nearly mass-degenerate with the lightest
supersymmetric particle is performed using the 176 pb^-1 of data collected at
189 GeV in 1998 with the L3 detector. Mass differences between the chargino and
the lightest supersymmetric particle below 4 GeV are considered. The presence
of a high transverse momentum photon is required to single out the signal from
the photon-photon interaction background. No evidence for charginos is found
and upper limits on the cross section for chargino pair production are set. For
the first time, in the case of heavy scalar leptons, chargino mass limits are
obtained for any \tilde{\chi}^{+-}_1 - \tilde{\chi}^0_1 mass difference
- …