2 research outputs found

    Risk Factors for Heart Disease in Working Railwaymen

    No full text
    Heart diseases are the most common non-communicable diseases worldwide. We examined the prevalence of risk factors for heart disease among a sub-population of working men. In total, 11,059 railway crew workers of the Russian Railways Company were included in the study. We also asked participants to answer several questions based on the WHO STEPwise approach to surveillance (STEPS) translated into Russian. Only 30% of drivers had normal body mass index (BMI), whereas 70% were overweight or obese. In 12% of subjects, total cholesterol was higher than 5 mmol/L. In 15% of participants, glucose level was higher than 5.5 mmol/L. 38% of drivers reported smoking. Physical inactivity was registered in 54% of persons. Only 29% ate according to the key principles of good diet quality. 24% of respondents had a family history of heart disease. MANOVA demonstrated that BMI was determined by age, profession, smoking, physical inactivity, and diet quality. As age increased, the number of people with normal cholesterol levels decreased. It was demonstrated that a correlation existed between glucose levels and BMI. In the total group, the correlation was 0.46 ( p 50 years of age group. This study demonstrated that there is a high prevalence of risk factors for heart disease in train drivers in the Russian Federation

    Flexible Strain-Sensitive Silicone-CNT Sensor for Human Motion Detection

    No full text
    This article describes the manufacturing technology of biocompatible flexible strain-sensitive sensor based on Ecoflex silicone and multi-walled carbon nanotubes (MWCNT). The sensor demonstrates resistive behavior. Structural, electrical, and mechanical characteristics are compared. It is shown that laser radiation significantly reduces the resistance of the material. Through laser radiation, electrically conductive networks of MWCNT are formed in a silicone matrix. The developed sensor demonstrates highly sensitive characteristics: gauge factor at 100% elongation −4.9, gauge factor at 90° bending −0.9%/deg, stretchability up to 725%, tensile strength 0.7 MPa, modulus of elasticity at 100% 46 kPa, and the temperature coefficient of resistance in the range of 30–40 °C is −2 × 10−3. There is a linear sensor response (with 1 ms response time) with a low hysteresis of ≤3%. An electronic unit for reading and processing sensor signals based on the ATXMEGA8E5-AU microcontroller has been developed. The unit was set to operate the sensor in the range of electrical resistance 5–150 kOhm. The Bluetooth module made it possible to transfer the received data to a personal computer. Currently, in the field of wearable technologies and health monitoring, a vital need is the development of flexible sensors attached to the human body to track various indicators. By integrating the sensor with the joints of the human hand, effective movement sensing has been demonstrated
    corecore