1,112 research outputs found

    On the sound of snapping shrimp

    Get PDF
    Snapping shrimp produce a snapping sound by an extremely rapid closure of their snapper claw. Source levels reported for Alpheus heterochaelis are as high as 220 dB (peak-to-peak) re. 1 µPa at 1 m distance. The loud snap has been attributed to the mechanical contact made when the snapper claw contracts. The recent ultra-high-speed imaging of the snapper claw closure at 40500 frames per second has revealed that the sound is, in fact, generated by the collapse of a cavitation bubble formed in a fast flowing water jet forced out from between the claws during claw closure. A temporal analysis of the sound recordings and the high-speed images shows that no sound is associated with the claw closure, while a very prominent signal is observed during the collapse of the cavitation bubble. Gallery of Fluid Motion\ud Award-winning entry 200

    Implementing electronic health records in hospitals:a systematic literature review

    Get PDF
    Background: The literature on implementing Electronic Health Records (EHR) in hospitals is very diverse. The objective of this study is to create an overview of the existing literature on EHR implementation in hospitals and to identify generally applicable findings and lessons for implementers. Methods: A systematic literature review of empirical research on EHR implementation was conducted. Databases used included Web of Knowledge, EBSCO, and Cochrane Library. Relevant references in the selected articles were also analyzed. Search terms included Electronic Health Record (and synonyms), implementation, and hospital (and synonyms). Articles had to meet the following requirements: (1) written in English, (2) full text available online, (3) based on primary empirical data, (4) focused on hospital-wide EHR implementation, and (5) satisfying established quality criteria. Results: Of the 364 initially identified articles, this study analyzes the 21 articles that met the requirements. From these articles, 19 interventions were identified that are generally applicable and these were placed in a framework consisting of the following three interacting dimensions: (1) EHR context, (2) EHR content, and (3) EHR implementation process. Conclusions: Although EHR systems are anticipated as having positive effects on the performance of hospitals, their implementation is a complex undertaking. This systematic review reveals reasons for this complexity and presents a framework of 19 interventions that can help overcome typical problems in EHR implementation. This framework can function as a reference for implementers in developing effective EHR implementation strategies for hospitals

    Breakup of diminutive Rayleigh jets

    Get PDF
    Discharging a liquid from a nozzle at sufficient large velocity leads to a continuous jet that due to capillary forces breaks up into droplets. Here we investigate the formation of microdroplets from the breakup of micron-sized jets with ultra high-speed imaging. The diminutive size of the jet implies a fast breakup time scale τc=ρr3/γ\tau_\mathrm{c} = \sqrt{\rho r^3 / \gamma} of the order of 100\,ns{}, and requires imaging at 14 million frames per second. We directly compare these experiments with a numerical lubrication approximation model that incorporates inertia, surface tension, and viscosity [Eggers and Dupont, J. Fluid Mech. 262, 205 (1994); Shi, Brenner, and Nagel, Science 265, 219 (1994)]. The lubrication model allows to efficiently explore the parameter space to investigate the effect of jet velocity and liquid viscosity on the formation of satellite droplets. In the phase diagram we identify regions where the formation of satellite droplets is suppressed. We compare the shape of the droplet at pinch-off between the lubrication approximation model and a boundary integral (BI) calculation, showing deviations at the final moment of the pinch-off. Inspite of this discrepancy, the results on pinch-off times and droplet and satellite droplet velocity obtained from the lubrication approximation agree with the high-speed imaging results

    Cyclic fatigue resistance tests of Nickel-Titanium rotary files using simulated canal and weight loading conditions

    Get PDF
    published_or_final_versio

    Organisatie-veranderingen

    Get PDF

    Ion distribution and ablation depth measurements of a fs-ps laser-irradiated solid tin target

    Get PDF
    The ablation of solid tin surfaces by an 800-nanometer-wavelength laser is studied for a pulse length range from 500 fs to 4.5 ps and a fluence range spanning 0.9 to 22 J/cm^2. The ablation depth and volume are obtained employing a high-numerical-aperture optical microscope, while the ion yield and energy distributions are obtained from a set of Faraday cups set up under various angles. We found a slight increase of the ion yield for an increasing pulse length, while the ablation depth is slightly decreasing. The ablation volume remained constant as a function of pulse length. The ablation depth follows a two-region logarithmic dependence on the fluence, in agreement with the available literature and theory. In the examined fluence range, the ion yield angular distribution is sharply peaked along the target normal at low fluences but rapidly broadens with increasing fluence. The total ionization fraction increases monotonically with fluence to a 5-6% maximum, which is substantially lower than the typical ionization fractions obtained with nanosecond-pulse ablation. The angular distribution of the ions does not depend on the laser pulse length within the measurement uncertainty. These results are of particular interest for the possible utilization of fs-ps laser systems in plasma sources of extreme ultraviolet light for nanolithography.Comment: 8 pages, 7 figure

    International Health Electives:defining learning outcomes for a unique experience

    Get PDF
    Background: An International Health Elective (IHE) can be a unique learning experience for students. However, it has proven difficult to clearly define learning outcomes that capture the complexity of an IHE and are aligned with future professional performance. This study aimed to further define learning outcomes for IHEs in low- to middle-income countries (LMIC) from a student perspective. Methods: We conducted a deductive analysis of pre-departure and post-elective reflective reports of fifth-year medical students who participated in an IHE as part of their program. This provided possible learning objectives that were further explored in semi-structured individual interviews with medical students who had recently returned from an IHE. Results: We analyzed 33 reports of students participating in an IHE from 2017–2019 and held 19 interviews. Thematic analysis revealed 9 themes: developing intercultural competence, developing appreciation for differences in health care delivery systems, understanding international health, understanding the global burden of disease, developing a career perspective, developing clinical skills in resource low settings, becoming cost conscious, developing social responsibility and self-actualization. Conclusions: We identified 9 learning outcomes that are directly and indirectly related to clinical practice. They add to the on-going discourse on the benefits of IHEs. These outcomes can be further developed by investigating the perspectives of home and host supervisors and educationalists, while taking the local context into account. Follow-up studies can evaluate to what extend these outcomes are achieve during an IHE.</p

    The Supera Interwoven Nitinol Stent as a Flow Diverting Device in Popliteal Aneurysms

    Get PDF
    PURPOSE: The feasibility of using a compressed interwoven Supera stent as a flow diverting device for popliteal aneurysms was recently demonstrated in patients. It is unclear, however, what the optimal flow diverting strategy is, because of the fusiform shape of popliteal aneurysms and their exposure to triphasic flow. To assess this flow diverting strategy for popliteal aneurysms, flow profiles and thrombus formation likelihood were investigated in popliteal aneurysm models. MATERIALS AND METHODS: Six popliteal aneurysm models were created and integrated into a pulsatile flow set-up. These models covered a bent and a straight anatomy in three configurations: control, single-lined and dual-lined Supera stents. Two-dimensional flow velocities were visualized by laser particle image velocimetry. In addition, the efficacy of the stent configurations for promoting aneurysm thrombosis was assessed by simulations of residence time and platelet activation. RESULTS: On average for the two anatomies, the Supera stent led to a twofold reduction of velocities in the aneurysm for single-lined stents, and a fourfold reduction for dual-lined stents. Forward flow was optimally diverted, whereas backward flow was generally deflected into the aneurysm. The dual-lined configuration led to residence times of 15–20 s, compared to 5–15 s for the single stent configurations. Platelet activation potential was not increased by the flow diverting stents. CONCLUSION: A compressed Supera stent was successfully able to divert flow in a popliteal aneurysm phantom. A dual-lined configuration demonstrated superior hemodynamic characteristics compared to its single-lined counterpart. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00270-022-03118-x
    corecore