1,088 research outputs found

    On the measurement uncertainty of microdosimetric quantities using diamond and silicon microdosimeters in carbon-ion beams

    Get PDF
    Purpose: The purpose of this paper is to compare the response of two different types of solid-state microdosimeters, that is, silicon and diamond, and their uncertainties. A study of the conversion of silicon microdosimetric spectra to the diamond equivalent for microdosimeters with different geometry of the sensitive volumes is performed, including the use of different stopping power databases. Method: Diamond and silicon microdosimeters were irradiated under the same conditions, aligned at the same depth in a carbon-ion beam at the MedAustron ion therapy center. In order to estimate the microdosimetric quantities, the readout electronic linearity was investigated with three different methods, that is, the first being a single linear regression, the second consisting of a double linear regression with a channel transition and last a multiple linear regression by splitting the data into odd and even groups. The uncertainty related to each of these methods was estimated as well. The edge calibration was performed using the intercept with the horizontal axis of the tangent through the inflection point of the Fermi function approximation multi-channel analyzer spectrum. It was assumed that this point corresponds to the maximum energy difference of particle traversing the sensitive volume (SV) for which the residual range difference in the continuous slowing down approximation is equal to the thickness of the SV of the microdosimeter. Four material conversion methods were explored, the edge method, the density method, the maximum-deposition energy method and the bin-by-bin transformation method. The uncertainties of the microdosimetric quantities resulting from the linearization, the edge calibration and the detectors thickness were also estimated. Results: It was found that the double linear regression had the lowest uncertainty for both microdosimeters. The propagated standard (k = 1) uncertainties on the frequency-mean lineal energy y¯FyˉF{\bar{y}}_{\rm{F}} and the dose-mean lineal energy y¯DyˉD{\bar{y}}_{\rm{D}} values from the marker point, in the spectra, in the plateau were 0.1% and 0.2%, respectively, for the diamond microdosimeter, whilst for the silicon microdosimeter data converted to diamond, the uncertainty was estimated to be 0.1%. In the range corresponding to the 90% of the amplitude of the Bragg Peak at the distal part of the Bragg curve (R90 ) the uncertainty was found to be 0.1%. The uncertainty propagation from the stopping power tables was estimated to be between 5% and 7% depending on the method. The uncertainty on the y¯FyˉF{\bar{y}}_{\rm{F}} and y¯DyˉD{\bar{y}}_{\rm{D}} coming from the thickness of the detectors varied between 0.3% and 0.5%. Conclusion: This article demonstrate that the linearity of the readout electronics affects the microdosimetric spectra with a difference in y¯FyˉF{\bar{y}}_{\rm{F}} values between the different linearization methods of up to 17.5%. The combined uncertainty was dominated by the uncertainty of stopping power on the edge

    Photo-physical properties of He-related color centers in diamond

    Get PDF
    Diamond is a promising platform for the development of technological applications in quantum optics and photonics. The quest for color centers with optimal photo-physical properties has led in recent years to the search for novel impurity-related defects in this material. Here, we report on a systematic investigation of the photo-physical properties of two He-related (HR) emission lines at 535 nm and 560 nm created in three different diamond substrates upon implantation with 1.3 MeV He+ ions and subsequent annealing. The spectral features of the HR centers were studied in an "optical grade" diamond substrate as a function of several physical parameters, namely the measurement temperature, the excitation wavelength and the intensity of external electric fields. The emission lifetimes of the 535 nm and 560 nm lines were also measured by means of time-gated photoluminescence measurements, yielding characteristic decay times of (29 +- 5) ns and (106 +- 10) ns, respectively. The Stark shifting of the HR centers under the application of an external electrical field was observed in a CVD diamond film equipped with buried graphitic electrodes, suggesting a lack of inversion symmetry in the defects' structure. Furthermore, the photoluminescence mapping under 405 nm excitation of a "detector grade" diamond sample implanted at a 1x1010 cm-2 He+ ion fluence enabled to identify the spectral features of both the HR emission lines from the same localized optical spots. The reported results provide a first insight towards the understanding of the structure of He-related defects in diamond and their possible utilization in practical applicationsComment: 9 pages, 3 figure

    Lateral IBIC characterization of single crystal synthetic diamond detectors

    Get PDF
    In order to evaluate the charge collection efficiency (CCE) profile of single-crystal diamond devices based on a p-type/intrinsic/metal configuration, a lateral Ion Beam Induced Charge (IBIC) analysis was performed over their cleaved cross sections using a 2 MeV proton microbeam. CCE profiles in the depth direction were extracted from the cross-sectional maps at variable bias voltage. IBIC spectra relevant to the depletion region extending beneath the frontal Schottky electrode show a 100% CCE, with a spectral resolution of about 1.5%. The dependence of the width of the high efficiency region from applied bias voltage allows the constant residual doping concentration of the active region to be evaluated. The region where the electric field is absent shows an exponentially decreasing CCE profile, from which it is possible to estimate the diffusion length of the minority carriers by means of a drift-diffusion model. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

    Dedicated multichannel readout ASIC coupled with single crystal diamond for dosimeter application

    Get PDF
    This paper reports on the tests of a low-noise, multi-channel readout integrated circuit used as a readout electronic front-end for a diamond multi-pixel dosimeter. The system is developed for dose distribution measurement in radiotherapy applications. The first 10-channel prototype chip was designed and fabricated in a 0.18 um CMOS process. Every channel includes a charge integrator with a 10 pF capacitor and a double slope A/D converter. The diamond multi-pixel detector, based on CVD synthetic single crystal diamond Schottky diodes, is made by a 3 × 3 sensor matrix. The overall device has been tested under irradiation with 6 MeV radio therapeutic photon beams at the Policlinico ``Tor Vergata'' (PTV) hospital. Measurements show a 20 fA RMS leakage current from the front-end input stage and a negligible dark current from the diamond detector, a stable temporal response and a good linear behaviour as a function of both dose and dose rate. These characteristics were common to each tested channel

    Radiotherapy electron beams collimated by small tubular applicators: Characterization by silicon and diamond diodes

    Get PDF
    High-energy electron beams generated by linear accelerators, typically in the range 6 to 20 MeV, are used in small field sizes for radiotherapy of localized superficial tumors. Unshielded silicon diodes (Si-D) are commonly considered suitable detectors for relative dose measurements in small electron fields due to their high spatial resolution. Recently, a novel synthetic single crystal diamond diode (SCDD) showed suitable properties for standard electron beams and small photon beams dosimetry. The aim of the present study is twofold: to characterize 6 to 15 MeV small electron beams shaped by using commercial tubular applicators with 2, 3, 4 and 5 cm diameter and to assess the dosimetric performance under such irradiation conditions of the novel SCDD dosimeter by comparison with commercially available dosimeters, namely a Si-D and a plane-parallel ionization chamber. Percentage depth dose curves, beam profiles and output factors (OFs) were measured. A good agreement among the dosimeters was observed in all of the performed measurements. As for the tubular applicators, two main effects were evidenced: (i) OFs larger than unity were measured for a number of field sizes and energies, with values up to about 1.3, that is an output 30% greater than that obtained at the 10 × 10 cm 2 reference field; (ii) for each diameter of the tubular applicator a noticeable increase of the OF values was observed with increasing beam energy, up to about 100% in the case of the smaller applicator. This OF behavior is remarkably different from what typically observed for small blocked fields having the same size and energy as those used in this study. OFs for tubular applicators depend considerably on the field size, so interpolation is unadvisable to predict the linear accelerator output for such applicators whereas reliable high-resolution detectors, as the silicon and diamond diodes used in this work allow OF measurements with uncertainties of about 1%. © 2013 Institute of Physics and Engineering in Medicine. Printed in the UK & the USA

    Array of time-of-flight diamond detectors for particle discrimination in laser driven p-11B fusion experiments

    Get PDF
    The detection of radiation emission in laser induced plasma experiments is an helpful method for gaining information on the physics of laser-matter interaction. Time-of-Flight (TOF) approach is a powerful and effective method to obtain timely spectra of particles accelerated from laser-generated plasma. To this respect, diamond-based detectors are very attractive due to their interesting features such as fast signal collection time, signal proportional to the energy deposited by the incident radiation, blindness to visible radiation, high radiation hardness and low leakage current at room temperature operation. Unfortunately, they cannot supply discrimination on the species of the incoming ions, but only their energies. This may be overcome using specific filtering foils to exploit the different stopping powers of ions of different species and energies. In this work we describe the method to distinguish particles using an array of TOF diamond detectors. A first prototype array, consisting of 2×2 diamond detectors, nominally identical and featuring by aluminum filters of different thicknesses, was developed and preliminary tested at PALS facility in Prague

    A 3-dimensional interdigitated electrode geometry for the enhancement of charge collection efficiency in diamond detectors

    Get PDF
    In this work, a single crystal CVD diamond film with a novel three-dimensional (3D) interdigitated electrode geometry has been fabricated with the reactive ion etching (RIE) technique in order to increase the charge collection efficiency (CCE) with respect to that obtained by standard superficial electrodes. The geometrical arrangement of the electric field lines due to the 3D patterning of the electrodes results in a shorter travel path for the excess charge carriers, thus contributing to a more efficient charge collection mechanism. The CCE of the device was mapped by means of the ion beam induced charge (IBIC) technique. A 1MeV proton microbeam was raster-scanned over the active area of the diamond detector under different bias voltage conditions, enabling to probe the charge transport properties of the detector up to a depth of 8 ìm below the sample surface. The experimental results, supported by the numerical simulations, show a significant improvement in the 3D detector performance (i.e. CCE, energy resolution, extension of the active area) if compared with the results obtained by standard surface metallic electrodes

    Thermal and fast neutron dosimetry using artificial single crystal diamond detectors

    Get PDF
    In this work we propose the artificial Single Crystal Diamond (SCD) detector covered with a thin layer (0.5 μm/4 μm) of 6LiF as a simultaneous thermal and fast neutron fluence monitor. Some interesting properties of the diamond response versus the neutron energy are evidenced thanks to Monte Carlo simulation using the MCNPX code which allows to propose the diamond detector also as an ambient dose equivalent (H(10)) monitor (REM counter). © 2011 Elsevier Ltd. All rights reserved
    • …