15 research outputs found

    Nonsurgical Procedures for Keratoconus Management

    Get PDF
    Objectives. To describe the past 20 years’ correction modalities for keratoconus and their visual outcomes and possible complications. Methods. A review of the published literature related to the visual outcomes and possible complications in the context of keratoconus management using nonsurgical procedures for the last 20 years (glasses and contact lenses) was performed. Original articles that reported the outcome of any correction modalities of keratoconus management were reviewed. Results. The most nonsurgical procedure used on keratoconus management is the contact lens fitting. Soft contact lenses and soft toric contact lenses, rigid gas-permeable contact lenses, piggyback contact lens system, hybrid contact lenses, and scleral and corneoscleral contact lenses form the contemporary range of available lens types for keratoconus management with contact lenses. All of them try to restore the vision, improve the quality of life, and delay surgical procedures in patients with this disease. Complications are derived from the intolerance of using contact lens, and the use of each depends on keratoconus severity. Conclusions. In the context of nonsurgical procedures, the use of contact lenses for the management of keratoconic patients represents a good alternative to restore vision and improve the quality of live in this population

    e-Estesia: A Serious Game for Reducing Arousal, Improving Emotional Regulation and Increasing Wellbeing in Individuals with Gambling Disorder

    Full text link
    Gambling disorder (GD) is associated with deficits in emotion regulation and impulsivity-related personality traits. In recent years there has been an increase in the use of serious games (SG) to address these factors with positive results. The aim of this study was to analyze the efficacy of the intervention with a new SG (e-Estesia), as an adjunct to a CBT intervention for GD. The sample comprised two groups (experimental group (n = 40) and control group (n = 64)) of patients with GD diagnosis. Both groups received 16 weekly CBT sessions and, concurrently, only the experimental group received 15 additional sessions with e-Estesia. Pre-post treatment with e-Estesia administered in both groups were: DSM-5 Criteria, South Oaks Gambling Screen, Symptom Checklist-Revised and measure of relapses, dropout and compliance of treatment. As regards the experimental group were also administered: Difficulties in Emotion Regulation Scale, Emotion Regulation Questionnaire, and Impulsive Behavior Scale. No statistically significant differences in the general psychopathological state, emotion regulation or impulsivity were found when comparing the groups. However, patients enrolled in the e-Estesia intervention had significantly less relapses and better indicators of treatment compliance than the control group. Considering these results, the use of complementary tools such as SG are useful for addressing GD

    Innovación docente en Prácticas de la asignatura Optometría V del Grado en Óptica y Optometría de la UCM

    Get PDF
    El desarrollo de las prácticas de esta asignatura tiene un componente teórico previo a la ejecución práctica y, en consecuencia, el uso de material en video que favorezcan un aprendizaje on-line activo, autónomo y colaborativo es de vital importancia en conceptos claves. Además, la resolución de casos clínicos a través de cuestiones auto-evaluativas fomenta el aprendizaje clínico basado en el desarrollo de las consultas optométricas con este tipo de pacientes

    Comparison of the impact of nesofilcon A hydrogel contact lens on the ocular surface and the comfort of presbyopic and non-presbyopic wearers

    Get PDF
    AIM: To assess and compare the impact of a daily disposable contact lens (CL) with high water content on the ocular surface and comfort of the presbyopic and non-presbyopic population after one day of use. METHODS: Totally 20 presbyopes and 30 non-presbyopes non-contact wearers were fitted with nesofilcon A CLs. CL thickness was measured to assess material stability during daily wear, and ocular surface parameters were also assessed. Optical quality was analyzed for all cases. In addition, CL comfort was rated. RESULTS: No significant differences were found in CL thickness, tear film osmolarity, average tear break-up time, bulbar redness, central corneal thickness, corneal volume, root-mean-square of higher-order aberrations (RMS of HOAs) and vertical and horizontal coma, either as a function of the group or time of use. A significant decrease in tear meniscus height and first break-up of the tear film was found in the presbyopic group (P=0.038; P=0.007 respectively). A decrease in spherical aberration coefficient was found after CL insertion (P=0.031 monofocal CL; P=0.023 low addition multifocal CL; P=0.016 high addition multifocal CL). Multifocal CL were thicker than monofocal CL (P=0.045). Comparison between groups showed more discomfort in presbyopes than non-presbyopes (P=0.003). CONCLUSION: This study evidence that the behavior of the daily disposable CL with high water content seems to be stable during the day of use. Ocular parameters measured during wear show that CL behavior is the same for presbyopes and non-presbyopes, being more uncomfortable for presbyopes

    Thoracic limb salvage by fibular free flap

    Get PDF
    The treatment of most fractures of the ulna and radius is usually performed by anatomical reduction and internal fixation, when damage is extensive and local soft tissue cannot provide a complete wound coverage, locoregional flaps present a suitable reconstructive benefit. A 35-year-old male patient suffered an exposed diaphysio-metaphyseal fracture with multi-fragmented distal radius. The patient was evaluated during a 10-day period at the National Institute of Rehabilitation, where the osteosynthesis material and a severe infectious process with necrosis were identified. Necrosectomy of the posterior compartment and removal of the osteosynthesis material was performed, a skin defect of approximately 22x16 cm was observed with a bone gap of 6 cm of radius and ulna. a fibula-free flap is placed to correct the skin defect and an external fixative used for bone alignment. The fibular free flap presents an excellent therapeutic alternative in the resolution of bone gaps with extensive skin defect. Whenever a trained microsurgery team is available, current scales of limb injury should be considered but not utilized for therapeutic approach, always trying to shift amputation as the first option, to the very last one of them

    Aplicación de un programa informatizado para emitir informes clínicos en la asignatura de Clínica Optométrica I

    Get PDF
    El objetivo es optimizar el uso de un programa informático de registro y almacenamiento de datos clínicos y la creación de una nueva herramienta para generar informes clínicos. Los informes clínicos forman parte de la evaluación del alumno

    PhDAY 2020 -FOO (Facultad de Óptica y Optometría)

    Get PDF
    Por cuarto año consecutivo los doctorandos de la Facultad de Óptica y Optometría de la Universidad Complutense de Madrid cuentan con un congreso propio organizado por y para ellos, el 4º PhDAY- FOO. Se trata de un congreso gratuito abierto en la que estos jóvenes científicos podrán presentar sus investigaciones al resto de sus compañeros predoctorales y a toda la comunidad universitaria que quiera disfrutar de este evento. Apunta en tu agenda: el 15 de octubre de 2020. En esta ocasión será un Congreso On-line para evitar que la incertidumbre asociada a la pandemia Covid-19 pudiera condicionar su celebración

    Use of advanced flap and microsurgery techniques in the resolution of mediastinitis as a complication of cardiac surgery

    Get PDF
    In the majority of cases, mediastinitis is a potential complication in any cardiac surgical procedure. The objective of this case report is to accurately describe how the combination of microsurgery and soft tissue flaps can be an effective therapeutic alternative in the treatment of mediastinitis as a complication of cardiac valve replacement. Female 63-year-old patient with a background of obesity, hypertension and extense cardiac interventions, she was programmed for necrosectomy with left pectoralis flap technique. Mediastinitis, although a rare complication of the sternotomy performed in cardiac surgery, occurring in 1-2%, carries a high mortality rate.  Early diagnosis of mediastinitis after cardiac surgery requires high clinical suspicion, initially making the diagnosis may be difficult, risk factors should be considered. An early surgical approach can reduce the morbidity and mortality of this condition. The pectoralis flap should be considered as a safe therapeutic option
    corecore