    IonCCDTM detector for miniature sector-field mass spectrometer: investigation of peak shape and detector surface artifacts induced by keV ion detection

    No full text
    A recently described ion charge coupled device detector IonCCD (Sinha and Wadsworth, Rev. Sci. Instrum. 76(2), 2005; Hadjar, J. Am. Soc. Mass Spectrom. 22(4), 612-624, 2011) is implemented in a miniature mass spectrometer of sector-field instrument type and Mattauch-Herzog (MH)-geometry (Rev. Sci. Instrum. 62(11), 2618-2620, 1991; Burgoyne, Hieftje and Hites J. Am. Soc. Mass Spectrom. 8(4), 307-318, 1997; Nishiguchi, Eur. J. Mass Spectrom. 14(1), 7-15, 2008) for simultaneous ion detection. In this article, we present first experimental evidence for the signature of energy loss the detected ion experiences in the detector material. The two energy loss processes involved at keV ion kinetic energies are electronic and nuclear stopping. Nuclear stopping is related to surface modification and thus damage of the IonCCD detector material. By application of the surface characterization techniques atomic force microscopy (AFM) and X-ray photoelectrons spectroscopy (XPS), we could show that the detector performance remains unaffected by ion impact for the parameter range observed in this study. Secondary electron emission from the (detector) surface is a feature typically related to electronic stopping. We show experimentally that the properties of the MH-mass spectrometer used in the experiments, in combination with the IonCCD, are ideally suited for observation of these stopping related secondary electrons, which manifest in reproducible artifacts in the mass spectra. The magnitude of the artifacts is found to increase linearly as a function of detected ion velocity. The experimental findings are in agreement with detailed modeling of the ion trajectories in the mass spectrometer. By comparison of experiment and simulation, we show that a detector bias retarding the ions or an increase of the B-field of the IonCCD can efficiently suppress the artifact, which is necessary for quantitative mass spectrometry

    Deciphering drift time measurements from travelling wave ion mobility spectrometry-mass spectrometry studies

    No full text
    Detailed knowledge of the tertiary and quaternary structure of proteins and protein complexes is of immense importance in understanding their functionality. Similarly, variations in the conformational states of proteins form the underlying mechanisms behind many biomolecular processes, numerous of which are disease-related. Thus, the availability of reliable and accurate biophysical techniques that can provide detailed information concerning these issues is of paramount importance. Ion mobility spectrometry (IMS) coupled to mass spectrometry (MS) offers a unique opportunity to separate multi-component biomolecular entities and to measure the molecular mass and collision cross-section of individual components in a single, rapid (<= 2 min) experiment, providing 3D-architectural information directly. Here we report a method of calibrating a commercially available electrospray ionisation (ESI)-travelling wave ion mobility spectrometry (TWIMS)-mass spectrometer using known cross-sectional areas determined for a range of biomolecules by conventional IMS-MS. Using this method of calibration, we have analysed a range of proteins of differing mass and 3D architecture in their native conformations by ESI-TWIMS-MS and found that the cross-sectional areas measured in this way compare extremely favourably with cross-sectional areas calculated using an in-house computing method based on Protein Data Bank NMR-derived co-ordinates. This not only provides a high degree of confidence in the calibration method, but also suggests that the gas phase ESI-TWIMS-MS measurements relate well to solution-based measurements derived from other biophysical techniques. In order to determine which instrumental parameters affect the ESI-TWIMS-MS cross-sectional area calibration, a systematic study of the parameters used to optimise TWIMS drift time separations has been carried out, observing the effect each parameter has on drift times and IMS resolution. Finally, the ESI-TWIMS-MS cross-sectional area calibration has been applied to the analysis of the amyloidogenic protein beta(2)-microglobulin and measurements for three co-populated conformational families, present under denaturing conditions, have been made: the folded, partially unfolded and unfolded states

    Computer Graphics and CAD Literature A Keyword-Indexed Bibliography

    No full text
    corecore