64 research outputs found

    Perfusion CT to evaluate the effect of transluminal angioplasty on cerebral perfusion in the treatment of vasospasm after subarachnoid hemorrhage

    Get PDF
    INTRODUCTION: Delayed ischemic neurologic deficits secondary to vasospasm are a major cause of morbidity and mortality after subarachnoid hemorrhage (SAH). Treatment of vasospasm after SAH is associated with complications, and reliable techniques for evaluating effects of treatment of vasospasm in such patients are warranted. We present the use of perfusion computed tomography (PTC) to evaluate the effect of transluminal percutaneous angioplasty in a with SAH and vasospasm-induced ischemia. METHODS: Dynamic PCT with deconvolution produced maps of time-to-peak, mean transit time, regional cerebral blood flow, and regional cerebral blood volume, with a computerized automated map of the infarct and penumbra. CT scanners with quadruple detector array were used before and after angioplasty. RESULTS: Before angioplasty and intraarterial papaverine, PCT showed normal to decreased cerebral blood flow and increased cerebral blood volume and mean transit time in the middle cerebral artery territory of the left hemisphere. After angioplasty and intraarterial papaverine, PCT showed normalization of perfusion parameters. CONCLUSION: PCT can be a useful technique in monitoring angioplasty treatment effects in patients with vasospasm after SA

    Clinical and Imaging Determinants of Collateral Status in Patients With Acute Ischemic Stroke in MR CLEAN Trial and Registry

    Get PDF
    Background and Purpose—Collateral circulation status at baseline is associated with functional outcome after ischemic stroke and effect of endovascular treatment. We aimed to identify clinical and imaging determinants that are associated with collateral grade on baseline computed tomography angiography in patients with acute ischemic stroke due to an anterior circulation large vessel occlusion. Methods—Patients included in the MR CLEAN trial (Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands; n=500) and MR CLEAN Registry (n=1488) were studied. Collateral status on baseline computed tomography angiography was scored from 0 (absent) to 3 (good). Multivariable ordinal logistic regression analyses were used to test the association of selected determinants with collateral status. Results—In total, 1988 patients were analyzed. Distribution of the collateral status was as follows: absent (7%, n=123), poor (32%, n=596), moderate (39%, n=735), and good (23%, n=422). Associations for a poor collateral status in a multivariable model existed for age (adjusted common odds ratio, 0.92 per 10 years [95% CI, 0.886–0.98]), male (adjusted common odds ratio, 0.64 [95% CI, 0.53–0.76]), blood glucose level (adjusted common odds ratio, 0.97 [95% CI, 0.95–1.00]), and occlusion of the intracranial segment of the internal carotid artery with occlusion of the terminus (adjusted common odds ratio 0.50 [95% CI, 0.41–0.61]). In contrast to previous studies, we did not find an association between cardiovascular risk factors and collateral status. Conclusions—Older age, male sex, high glucose levels, and intracranial internal carotid artery with occlusion of the terminus occlusions are associated with poor computed tomography angiography collateral grades in patients with acute ischemic stroke eligible for endovascular treatment

    Feasibility study of computed tomography colonography using limited bowel preparation at normal and low-dose levels study

    Get PDF
    The purpose was to evaluate low-dose CT colonography without cathartic cleansing in terms of image quality, polyp visualization and patient acceptance. Sixty-one patients scheduled for colonoscopy started a low-fiber diet, lactulose and amidotrizoic-acid for fecal tagging 2 days prior to the CT scan (standard dose, 5.8–8.2 mSv). The original raw data of 51 patients were modified and reconstructed at simulated 2.3 and 0.7 mSv levels. Two observers evaluated the standard dose scan regarding image quality and polyps. A third evaluated the presence of polyps at all three mSv levels in a blinded prospective way. All observers were blinded to the reference standard: colonoscopy. At three times patients were given questionnaires relating to their experiences and preference. Image quality was sufficient in all patients, but significantly lower in the cecum, sigmoid and rectum. The two observers correctly identified respectively 10/15 (67%) and 9/15 (60%) polyps ≥10 mm, with 5 and 8 false-positive lesions (standard dose scan). Dose reduction down to 0.7 mSv was not associated with significant changes in diagnostic value (polyps ≥10 mm). Eighty percent of patients preferred CT colonography and 13% preferred colonoscopy (P<0.001). CT colonography without cleansing is preferred to colonoscopy and shows sufficient image quality and moderate sensitivity, without impaired diagnostic value at dose-levels as low as 0.7 mSv

    Informal modernism - spontaneous building in Mexico City

    Get PDF
    Die überall aufragenden Betonstützen der unfertigen Selbstbau-Häuser sind in Mexiko-Stadt zum Symbol des spontanen Bauens geworden. Gleichzeitig haben die chaotischen Hüttensiedlungen längst einem routinierten Selbsthilfe-Städtebau Platz gemacht, der das Wohnungsproblem informell, aber gut organisiert und im großen Stil angeht. So kann man auch von einer improvisierten oder "informellen Moderne" sprechen, die sich die Menschen überall dort geschaffen haben, wo die formelle Stadtplanung und Wohnungsversorgung versagt oder auf halbem Wege stecken geblieben ist.The looming concrete columns of unfinished self-help-houses in Mexico City have become a symbol of spontaneous building worldwide. At the same time, the chaotic clusters of miserable huts have long since made way for a routinized self help urbanism, which approaches the housing problem informally, yet well organized and on a large scale. Thus one may speak of an improvised or "informal modernism" that people have created everywhere, where formal city planning and housing has either failed or gotten stuck midway

    Prehospital Stroke Triage:A Modeling Study on the Impact of Triage Tools in Different Regions

    Get PDF
    Background and purpose: Direct transportation to a thrombectomy-capable intervention center is beneficial for patients with ischemic stroke due to large vessel occlusion (LVO), but can delay intravenous thrombolytics (IVT). The aim of this modeling study was to estimate the effect of prehospital triage strategies on treatment delays and overtriage in different regions. Methods: We used data from two prospective cohort studies in the Netherlands: the Leiden Prehospital Stroke Study and the PRESTO study. We included stroke code patients within 6 h from symptom onset. We modeled outcomes of Rapid Arterial oCclusion Evaluation (RACE) scale triage and triage with a personalized decision tool, using drip-and-ship as reference. Main outcomes were overtriage (stroke code patients incorrectly triaged to an intervention center), reduced delay to endovascular thrombectomy (EVT), and delay to IVT. Results: We included 1798 stroke code patients from four ambulance regions. Per region, overtriage ranged from 1-13% (RACE triage) and 3-15% (personalized tool). Reduction of delay to EVT varied by region between 24 ± 5 min (n = 6) to 78 ± 3 (n = 2), while IVT delay increased with 5 (n = 5) to 15 min (n = 21) for non-LVO patients. The personalized tool reduced delay to EVT for more patients (25 ± 4 min [n = 8] to 49 ± 13 [n = 5]), while delaying IVT with 3-14 min (8-24 patients). In region C, most EVT patients were treated faster (reduction of delay to EVT 31 ± 6 min (n = 35), with RACE triage and the personalized tool. Conclusions: In this modeling study, we showed that prehospital triage reduced time to EVT without disproportionate IVT delay, compared to a drip-and-ship strategy. The effect of triage strategies and the associated overtriage varied between regions. Implementation of prehospital triage should therefore be considered on a regional level.</p

    Digital chest radiography: an update on modern technology, dose containment and control of image quality

    Get PDF
    The introduction of digital radiography not only has revolutionized communication between radiologists and clinicians, but also has improved image quality and allowed for further reduction of patient exposure. However, digital radiography also poses risks, such as unnoticed increases in patient dose and suboptimum image processing that may lead to suppression of diagnostic information. Advanced processing techniques, such as temporal subtraction, dual-energy subtraction and computer-aided detection (CAD) will play an increasing role in the future and are all targeted to decrease the influence of distracting anatomic background structures and to ease the detection of focal and subtle lesions. This review summarizes the most recent technical developments with regard to new detector techniques, options for dose reduction and optimized image processing. It explains the meaning of the exposure indicator or the dose reference level as tools for the radiologist to control the dose. It also provides an overview over the multitude of studies conducted in recent years to evaluate the options of these new developments to realize the principle of ALARA. The focus of the review is hereby on adult applications, the relationship between dose and image quality and the differences between the various detector systems

    Signals, noise and the join-count statistic

    Full text link

    Digital radiography of the chest: Reassessment of the high-voltage technique?

    Full text link
    • …
    corecore