5 research outputs found

    Bentall procedure 39 years after implantation of a Starr-Edwards Aortic Caged- Ball-Valve Prosthesis

    Get PDF
    We report a case of a male patient who received an implantation of a Starr-Edwards-caged-ball-valve-prosthesis in 1967. The surgery and postoperative course were without complications and the patient recovered well after the operation. For the next four decades, the patient remained asymptomatic - no restrictions on his lifestyle and without any complications. In 2006, 39 years after the initial operation, we performed a Bentall-Procedure to treat an aortic ascendens aneurysm with diameters of 6.0 × 6.5 cm: we explanted the old Starr-Edwards-aortic-caged-ball-valve-prosthesis and replaced the ascending aorta with a 29 mm St.Jude Medical aortic-valve-composite-graft and re-implanted the coronary arteries

    Coronary artery bypass surgery in a patient with Kartagener syndrome: a case report and literature review

    Get PDF
    Kartagener syndrome consists of congenital bronchiectasis, sinusitis, and total situs inversus in half of the patients. A patient diagnosed with Kartagener syndrome was reffered to our department due to 3-vessel coronary disease. An off-pump coronary artery bypass operation was performed using both internal thoracic arteries and a saphenous vein graft. We performed a literature review for cases with Kartagener syndrome, coronary surgery and dextrocardia. Although a few cases of dextrocardia were found in the literature, no case of Kartagener syndrome was mentioned

    Investigating the failure to aspirate subglottic secretions with the evac endotracheal tube

    No full text
    BACKGROUND: Aspiration of subglottic secretions is a widely used intervention for prevention of ventilator-associated pneumonia. However, using the Hi-Lo® Evac endotracheal tube (Hi-Lo Evac; Mallinckrodt; Athlone, Ireland) (Evac ETT), dysfunction of the suction lumen and subsequent failure to aspirate the subglottic secretions are common. Our objective in this study was to determine the causes of suction lumen dysfunction experienced with the Evac ETT. METHODS: We studied 40 adult patients intubated with the Evac ETT. In all cases for which dysfunction of the suction lumen was observed, the subglottic suction port was examined visually using a flexible bronchoscope. RESULTS: Dysfunction of the suction lumen occurred in 19 of 40 patients (48%). In 17 of these (43%), it was attributed to blockage of the subglottic suction port by suctioned tracheal mucosa. CONCLUSION: Evacuation of subglottic secretions using the Evac ETT is often ineffective due to prolapse of tracheal mucosa into the subglottic suction port. © 2007 by International Anesthesia Research Society

    Hemodynamic effects of peri-operative statin therapy in on-pump cardiac surgery patients

    No full text
    Abstract Background Peri-operative statin therapy in cardiac surgery cases is reported to reduce the rate of mortality, stroke, postoperative atrial fibrillation, and systemic inflammation. Systemic inflammation could affect the hemodynamic parameters and stability. We set out to study the effect of statin therapy on perioperative hemodynamic parameters and its clinical outcome. Methods In a single center study from 2006 to 2007, peri-operative hemodynamic parameters of 478 patients, who underwent cardiac surgery with cardiopulmonary bypass, were measured. Patients were divided into those who received perioperative statin therapy (n = 276; statin group) and those who did not receive statin therapy (n = 202; no-statin group). The two groups were compared together using Kolmogorov-Smirnov-Test, Fisher’s-Exact-Test, and Student’s-T-test. A p value  Results There was no significant difference in the preoperative risk factors. Onset of postoperative atrial fibrillation was not affected by statin therapy. Extended hemodynamic measurements revealed no significant difference between the two groups, apart from Systemic Vascular Resistance Index (SVRI) . The no-statin group had a significantly higher SVRI (882 ± 206 vs. 1050 ± 501 dyn s/cm5/m2, p = 0.022). Inotropic support was the same in both groups and no significant difference in the mortality rate was noticed. Also, hemodynamic parameters were not affected by different types and doses of statins. Conclusions Perioperative statin therapy for patients undergoing on-pump coronary bypass grafting or valvular surgery, does not affect the hemodynamic parameters and its clinical outcome.</p
    corecore