14 research outputs found

    Oral mucosal lesions and their association with sociodemographic, behavioral, and health status factors

    Get PDF
    The aim of this study was to evaluate the frequency of oral mucosal lesions and their associations with sociodemographic, health, and behavioral factors in a southern Brazilian population. Information was collected from participants (n = 801) using a structured questionnaire during an oral cancer screening campaign held at an agribusiness show in southern Brazil in 2009. Data were described using frequency distributions or means and standard deviations. Associations between independent variables and outcomes were assessed using the Chi-squared test. A total of 465 lesions were detected (actinic cheilitis: n = 204, 25.5%; candidiasis: n = 50, 6.2%; fibrous inflammatory hyperplasia: n = 42, 5.2%; ulceration, n = 33, 4.1%; hemangioma: n = 14, 1.7%; leukoplakia: n = 11, 1.4%). Candidiasis, actinic cheilitis, and fibrous inflammatory hyperplasia were associated significantly with literacy. Actinic cheilitis was also associated significantly with sun exposure and hat use, and leukoplakia was associated with smoking. The high frequency of oral mucosal lesions observed highlights the importance of education about risk factors. Additionally, training of health professionals, mainly those from public health services, in the use of preventive and community education strategies is needed

    Assessing the risk of bias in randomized controlled trials in the field of dentistry indexed in the Lilacs (Literatura Latino-Americana e do Caribe em Ciências da Saúde) database

    Full text link

    Laser Influence on Dental Sensitivity Compared to Other Light Sources Used During In-office Dental Bleaching: Systematic Review and Meta-analysis

    Full text link
    Clinical Relevance The use of laser light during bleaching will not reduce the incidence or severity of sensitivity and will not increase the degree of color change compared with nonlaser light sources. SUMMARY Objective: To evaluate whether the use of laser during in-office bleaching promotes a reduction in dental sensitivity after bleaching compared with other light sources. Methods: The present review was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) and is registered with PROSPERO (CDR42018096591). Searches were conducted in the PubMed/Medline, Web of Science, and Cochrane Library databases for relevant articles published up to August 2018. Only randomized clinical trials among adults that compared the use of laser during in-office whitening and other light sources were considered eligible. Results: After analysis of the texts retrieved during the database search, six articles met the eligibility criteria and were selected for the present review. For the outcome dental sensitivity, no significant difference was found favoring any type of light either for intensity (mean difference [MD]: −1.60; confidence interval [CI]: −3.42 to 0.22; p=0.09) or incidence (MD: 1.00; CI: 0.755 to 1.33; p=1.00). Regarding change in tooth color, no significant differences were found between the use of the laser and other light sources (MD: −2.22; CI: −6.36 to 1.93; p=0.29). Conclusions: Within the limitations of the present study, laser exerts no influence on tooth sensitivity compared with other light sources when used during in-office bleaching. The included studies demonstrated that laser use during in-office bleaching may have no influence on tooth color change. </jats:sec

    Effect of Bleaching Gel Concentration on Tooth Color and Sensitivity: A Systematic Review and Meta-analysis

    Full text link
    SUMMARY Objective: The aim of this systematic review and meta-analysis was to evaluate a high concentration of hydrogen peroxide (35%) regarding tooth sensitivity and color change in tooth bleaching in comparison to low concentrations (6% to 20%). Methods and Materials: This review was conducted using the criteria of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses and is registered on the Prospective Register of Systematic Reviews (CRD42017064493). The PICO question was “Does a concentration of hydrogen peroxide ≥35% using in-office bleaching procedure contribute to greater tooth sensitivity?” A search was made in PubMed/MEDLINE, Scopus, and the Cochrane Library. Results: Fourteen studies were selected for the qualitative analysis and seven for quantitative analysis. A total of 649 patients were evaluated (mean age: 36.32 years; range: 13.9 to 31 years), and the follow-up period ranged from one week to 12 months. The meta-analysis demonstrated that tooth sensitivity was higher in the patients submitted to treatment involving a high concentration of hydrogen peroxide (0.67; 95% confidence interval [CI]: 0.44 to 1.03; p=0.04; I2: 56%), and a significant difference was found regarding objective color ΔE (1.53; 95% CI: 2.99 to 0.08; p&amp;lt;0.0001; I2: 82%) but no significant difference was found regarding subjective color ΔSGU (0.24; CI: 0.75 to 1.23; p&amp;lt;0.00001; I2: 89%). Conclusions: This study indicated that a lower concentration of hydrogen peroxide causes less tooth sensitivity and better effectiveness in objective color change (ΔE); however, there is no difference between them related to subjective color (ΔSGU). </jats:sec

    Clinical Efficiency of Self-etching One-Step and Two-Step Adhesives in NCCL: A Systematic Review and Meta-analysis

    Full text link
    Clinical Relevance One-step self-etch adhesive systems provide a clinical time gain, decreasing the number of clinical steps. When a clinician is able to follow a simpler process of adhesion there is less chance of adhesive failure. SUMMARY Objective: A systematic review and meta-analyses were performed to evaluate whether one-step self-etching (1SSE) adhesive systems are as effective as two-step self-etching (2SSE) adhesives in noncarious cervical lesion (NCCL) restorations. Methods: This systematic review was conducted according to the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) and recorded in the PROSPERO (CRD42018096747). Electronic systematic searches were conducted in the following databases: PubMed/MEDLINE, Scopus, and Cochrane Library for published articles. Only randomized clinical trials that compared 1SSE with 2SSE adhesives systems were selected. The outcomes were retention, postoperative sensitivity, secondary caries, color match, marginal discoloration, marginal adaptation, and anatomical form. Results: The searches resulted in 476 studies. After applying the eligibility criteria, five randomized controlled trials were selected in which 822 restorations in NCCLs were distributed in 237 patients. The results showed no statistical difference between 1SSE and 2SSE in relation to retention (p=0.23; relative risk [RR]=1.55; 95% confidence interval [CI]=0.76, 3.19), postoperative sensitivity ( p=0.50; RR=3.00; 95% CI=0.13, 70.64), Secondary caries (p=0.63; RR=0.68; 95% CI=0.14, 3.31), color match (p=0.41; RR=0.64; 95% CI=0.23, 1.83), marginal discoloration (p=0.93; RR=1.02; 95% CI=0.65, 1.61), and anatomical form (p=0.56; RR=1.38; 95% CI=0.46, 4.13). However there was statistical difference in relation to marginal adaptation ( p=0.01; RR=1.95; 95% CI=1.14, 3.34). Conclusion: This systematic review with meta-analysis revealed that both 1SSE and 2SSE adhesive systems have comparable clinical effectiveness in a follow-up period of 12 to 24 months, except in relation to marginal adaptation. </jats:sec

    Conduction velocity of the rabbit facial nerve: a noninvasive functional evaluation Velocidade de condução no nervo facial do coelho: uma avaliação funcional não invasiva

    Get PDF
    The aim of this study was to evaluate standardized conduction velocity data for uninjured facial nerve and facial nerve repaired with autologous graft nerves and synthetic materials. An evaluation was made measuring the preoperative differences in the facial nerve conduction velocities on either side, and ascertaining the existence of a positive correlation between facial nerve conduction velocity and the number of axons regenerated postoperatively. In 17 rabbits, bilateral facial nerve motor action potentials were recorded pre- and postoperatively. The stimulation surface electrodes were placed on the auricular pavilion (facial nerve trunk) and the recording surface electrodes were placed on the quadratus labii inferior muscle. The facial nerves were isolated, transected and separated 10 mm apart. The gap between the two nerve ends was repaired with autologous nerve grafts and PTFE-e (polytetrafluoroethylene) or collagen tubes. The mean of maximal conduction velocity of the facial nerve was 41.10 m/s. After 15 days no nerve conduction was evoked in the evaluated group. For the period of 2 and 4 months the mean conduction velocity was approximately 50% of the normal value in the subgroups assessed. A significant correlation was observed between the conduction velocity and the number of regenerated axons. Noninvasive functional evaluation with surface electrodes can be useful for stimulating and recording muscle action potentials and for assessing the functional state of the facial nerve.<br>O objetivo deste estudo foi avaliar os dados padronizados de velocidade de condução para o nervo facial não lesado e o nervo facial reparado com enxerto autógeno e com materiais sintéticos. Na avaliação foram medidas as diferenças pré-operatórias de velocidade de condução do nervo facial em cada lado e verificada a existência de uma correlação positiva entre a velocidade de condução do nervo facial e o número de axônios regenerados no pós-operatório. O potencial de ação motora bilateral do nervo facial de 17 coelhos foi registrado no pré e no pós-operatório. Os eletrodos superficiais de estimulação foram colocados no pavilhão auricular (tronco do nervo facial) e os eletrodos superficiais de gravação foram colocados no músculo quadratus labii inferior. Os nervos faciais foram isolados, transeccionados e separados a 10 mm. O espaço entre os dois cotos nervosos terminais foi reparado com enxertos nervosos autólogos e PTFE-e (politetrafluoretileno) ou tubos de colágeno. A média da máxima velocidade de condução do nervo facial foi 41,10 m/s. Nenhuma condução nervosa foi observada no grupo avaliado após 15 dias. A velocidade de condução média nos subgrupos avaliados para o período de 2 e 4 meses foi de aproximadamente 50% do valor normal. A avaliação funcional não invasiva com eletrodos de superfície pode ser útil para a estimulação e registro do potencial de ação muscular e para medir o estado funcional do nervo facial
    corecore