376 research outputs found
Fonti documentarie e istituzioni culturali nelle città venete dei decenni centrali dell’Ottocento: archivi e biblioteche municipali
Ricerca dedicata alle pratiche di conservazione e ordinamento della documentazione storica medievale e moderna negli archivi municipali delle cittĂ venete, prima e dopo l'unit
Intervista ad Attilio Bartoli Langeli
Intervista a uno dei maggiori diplomatisti italiani del Novecent
Cognitive modulation of psychophysical, respiratory and autonomic responses to cold pressor test
In healthy subjects with high hypnotisability (highs) under hypnosis, subjectively effective suggestions for analgesia abolish the increases in blood pressure associated with cold pressor test (cpt) by reducing the peripheral vascular resistance. The aim of the present study was to investigate the effects of the suggestions of analgesia on the responses to cpt in healthy highs (n = 22) and in low hypnotisable participants (lows, n = 22) out of hypnosis. Cpt was administered without (CPT) and
with suggestions for analgesia (CPT+AN). Psychophysical (pain intensity, pain threshold, cpt duration (time of immersion) and pain tolerance, defined as the difference between cpt duration and pain threshold), respiratory (amplitude and frequency) and autonomic variables (tonic skin conductance, mean RR interval (RR = 1/heart rate), blood pressure, skin blood flow) were studied. The suggestions for analgesia increased cpt duration and RR in both groups, but decreased pain intensity and enhanced pain threshold only in highs; in both groups they did not modulate systolic blood pressure, tonic skin conductance and skin blood flow; thus, increased parasympathetic activity appears responsible for the heart rate reduction induced by suggestions in both groups. In conclusion, our findings show that suggestions modulate pain experience differentially in highs and lows, and are partially effective also in lows. We hypothesize that the mechanisms responsible for the efficacy of suggestions in healthy lows may be involved also in their efficacy in chronic pain patients with
low hypnotisability
Free electron lifetime achievements in Liquid Argon Imaging TPC
A key feature for the success of the liquid Argon imaging TPC (LAr-TPC)
technology is the industrial purification against electro-negative impurities,
especially Oxygen and Nitrogen remnants, which have to be continuously kept at
an exceptionally low level by filtering and recirculating liquid Argon.
Improved purification techniques have been applied to a 120 liters LAr-TPC test
facility in the INFN-LNL laboratory. Through-going muon tracks have been used
to determine the free electron lifetime in liquid Argon against
electro-negative impurities. The short path length here observed (30 cm) is
compensated by the high accuracy in the observation of the specific ionization
of cosmic ray muons at sea level as a function of the drift distance. A free
electron lifetime of (21.4+7.3-4.3) ms, namely > 15.8 ms at 90 % C.L. has been
observed over several weeks under stable conditions, corresponding to a
residual Oxygen equivalent of about 15 ppt (part per trillion). At 500 V/cm,
the free electron speed is 1.5 m/ms. In a LAr-TPC a free electron lifetime in
excess of 15 ms corresponds for instance to an attenuation of less than 15 %
after a drift path of 5 m, opening the way to the operation of the LAr-TPC with
exceptionally long drift distances.Comment: 15 pages, 10 figures; Accepted for publication in JINS
Search for anomalies in the neutrino sector with muon spectrometers and large LArTPC imaging detectors at CERN
A new experiment with an intense ~2 GeV neutrino beam at CERN SPS is proposed
in order to definitely clarify the possible existence of additional neutrino
states, as pointed out by neutrino calibration source experiments, reactor and
accelerator experiments and measure the corresponding oscillation parameters.
The experiment is based on two identical LAr-TPCs complemented by magnetized
spectrometers detecting electron and muon neutrino events at Far and Near
positions, 1600 m and 300 m from the proton target, respectively. The ICARUS
T600 detector, the largest LAr-TPC ever built with a size of about 600 ton of
imaging mass, now running in the LNGS underground laboratory, will be moved at
the CERN Far position. An additional 1/4 of the T600 detector (T150) will be
constructed and located in the Near position. Two large area spectrometers will
be placed downstream of the two LAr-TPC detectors to perform charge
identification and muon momentum measurements from sub-GeV to several GeV
energy range, greatly complementing the physics capabilities. This experiment
will offer remarkable discovery potentialities, collecting a very large number
of unbiased events both in the neutrino and antineutrino channels, largely
adequate to definitely settle the origin of the observed neutrino-related
anomalies.Comment: Contribution to the European Strategy for Particle Physics - Open
Symposium Preparatory Group, Kracow 10-12 September 201
A local trigger system for the large LAr-TPC detector
A special dedicated double-rebinning algorithm has been successfully developed in order to extract the physical hit signal from the TPC wires. This solution has been implemented on digital boards, allowing to realize a local trigger able to identify even localized low-energy small events
Search for anomalies in the {\nu}e appearance from a {\nu}{\mu} beam
We report an updated result from the ICARUS experiment on the search for
{\nu}{\mu} ->{\nu}e anomalies with the CNGS beam, produced at CERN with an
average energy of 20 GeV and travelling 730 km to the Gran Sasso Laboratory.
The present analysis is based on a total sample of 1995 events of CNGS neutrino
interactions, which corresponds to an almost doubled sample with respect to the
previously published result. Four clear {\nu}e events have been visually
identified over the full sample, compared with an expectation of 6.4 +- 0.9
events from conventional sources. The result is compatible with the absence of
additional anomalous contributions. At 90% and 99% confidence levels the limits
to possible oscillated events are 3.7 and 8.3 respectively. The corresponding
limit to oscillation probability becomes consequently 3.4 x 10-3 and 7.6 x 10-3
respectively. The present result confirms, with an improved sensitivity, the
early result already published by the ICARUS collaboration
A new, very massive modular Liquid Argon Imaging Chamber to detect low energy off-axis neutrinos from the CNGS beam. (Project MODULAr)
The paper is considering an opportunity for the CERN/GranSasso (CNGS)
neutrino complex, concurrent time-wise with T2K and NOvA, to search for
theta_13 oscillations and CP violation. Compared with large water Cherenkov
(T2K) and fine grained scintillators (NOvA), the LAr-TPC offers a higher
detection efficiency and a lower backgrounds, since virtually all channels may
be unambiguously recognized. The present proposal, called MODULAr, describes a
20 kt fiducial volume LAr-TPC, following very closely the technology developed
for the ICARUS-T60o, and is focused on the following activities, for which we
seek an extended international collaboration:
(1) the neutrino beam from the CERN 400 GeV proton beam and an optimised horn
focussing, eventually with an increased intensity in the framework of the LHC
accelerator improvement program;
(2) A new experimental area LNGS-B, of at least 50000 m3 at 10 km off-axis
from the main Laboratory, eventually upgradable to larger sizes. A location is
under consideration at about 1.2 km equivalent water depth;
(3) A new LAr Imaging detector of at least 20 kt fiducial mass. Such an
increase in the volume over the current ICARUS T600 needs to be carefully
considered. It is concluded that a very large mass is best realised with a set
of many identical, independent units, each of 5 kt, "cloning" the technology of
the T600. Further phases may foresee extensions of MODULAr to meet future
physics goals.
The experiment might reasonably be operational in about 4/5 years, provided a
new hall is excavated in the vicinity of the Gran Sasso Laboratory and adequate
funding and participation are made available.Comment: Correspondig Author: C. Rubbia (E-mail: [email protected]), 33
pages, 11 figure
Measurement of a large electron lifetime in a liquid argon TPC
An unprecedentedly high value of electron lifetime in a liquid argon TPC, about 21ms, has been measured in a test facility at INFN-LNL. This results opens the way to the future development of TPCs with very long drift distances
- …