17 research outputs found

    Commentary: AADI: New kid on the block

    No full text

    Rescue of failing or failed trabeculectomy blebs with slit-lamp needling and adjunctive mitomycin C in Indian eyes

    No full text
    Purpose: The aim of this study is to investigate the efficacy and safety of needling-revision augmented with a high dose of mitomycin C (MMC) in failing or failed blebs after trabeculectomy in Indian eyes. Methods: Prospective, noncomparative, interventional study. All patients (>18 years) who had raised intraocular pressure (IOP) following trabeculectomy (>6 weeks and <2 years), who had a flat bleb, bleb encapsulation, and/or required antiglaucoma medication (AGM) for IOP control were eligible for inclusion. MMC was injected subconjunctivally at least ½ hour before the needling procedure was carried out at the slit lamp in the outpatient's clinic. Results: Thirty-nine eyes of 38 patients were included. The median follow-up was 20 months and time interval between trabeculectomy and needle revision was 113 days. Initially, in all cases, aqueous flow was re-established with a raised bleb; 7 eyes required repeat needling. IOP decreased from median 24 mmHg (Q1 21, Q3 27, interquartile range [IQR] 6, range 18–35) preneedling to median 14 mmHg (Q1 10, Q3 16, IQR 6, range 6–18) postneedling at last follow-up (P < 0.0001, 95% confidence interval [CI]: 8.2–13.0). The use of AGM reduced from median 1 (Q1 0, Q3 3, IQR 3, range 0–4) preneedling to median 0 postneedling (P < 0.0001, 95% CI: 1–2). Complete success was seen in 28 eyes (71.8%, 95% CI: 71.1%–96.4%); another 5 eyes (12.8%) were controlled with AGM (qualified success) with overall success of 84.6%. Most complications were transient in nature with resolution within 1 week. One patient developed hypotony, and another developed a late bleb leak. Conclusion: Needling revision augmented with high-dose MMC, at the slit lamp, effectively rescues failing or failed filtration, and appears to be safe

    Commentary: AADI: New kid on the block

    No full text

    Combined cataract extraction with a new nonvalved glaucoma drainage device in adult eyes with cataract and refractory glaucoma

    No full text
    Purpose: The purpose of the study is to report the outcomes of simultaneous cataract extraction (CE) and a new nonvalved glaucoma drainage device (GDD), Aurolab Aqueous Drainage Implant (AADI), in eyes with cataract and refractory glaucoma. Methods: This was a non-comparative, interventional, retrospective study. Consecutive patients who underwent AADI together with phacoemulsification from June-2015 to January-2017 by a single fellowship trained glaucoma surgeon with documented 3-months of follow-up were included. The main outcomes were intraocular pressure (IOP), antiglaucoma medication (AGM), visual acuity, and complications. Results: We included 19 eyes of 17 patients with average follow-up of 14.4 ± 8.4 months. IOP and AGM reduced from 36.9 ± 11.1 mmHg and 4 ± 0.8 preoperatively to 12 ± 4.5 mmHg and 0.8 ± 1.2, respectively (P < 0.001). Complications were seen in seven eyes (36.8%). Total success was seen in 17 eyes (89.5%). None of the patients lost vision. Conclusion: Combining cataract extraction with the new non-valved Aurolab Aqueous Drainage Implant, appears to be an effective and safe technique in eyes with refractory glaucoma and cataract. Larger studies and further follow-up is recommended for such patients

    Phaco-endocycloplasty: A novel technique for management of ring iridociliary cyst presenting as acute angle closure

    No full text
    Iridociliary cysts of pigment epithelium are rare, ring cysts being rarer still, and usually benign in their clinical course. Presented here is a case of ring iridociliary cyst that resulted in secondary synechial angle closure with an acutely elevated intraocular pressure, refractory to medical treatment. Primary endocycloplasty and cataract extraction with implant were used successfully to manage the case
    corecore