30 research outputs found

    Effect of angiotensin-converting enzyme inhibitor and angiotensin receptor blocker initiation on organ support-free days in patients hospitalized with COVID-19

    Get PDF
    IMPORTANCE Overactivation of the renin-angiotensin system (RAS) may contribute to poor clinical outcomes in patients with COVID-19. Objective To determine whether angiotensin-converting enzyme (ACE) inhibitor or angiotensin receptor blocker (ARB) initiation improves outcomes in patients hospitalized for COVID-19. DESIGN, SETTING, AND PARTICIPANTS In an ongoing, adaptive platform randomized clinical trial, 721 critically ill and 58 non–critically ill hospitalized adults were randomized to receive an RAS inhibitor or control between March 16, 2021, and February 25, 2022, at 69 sites in 7 countries (final follow-up on June 1, 2022). INTERVENTIONS Patients were randomized to receive open-label initiation of an ACE inhibitor (n = 257), ARB (n = 248), ARB in combination with DMX-200 (a chemokine receptor-2 inhibitor; n = 10), or no RAS inhibitor (control; n = 264) for up to 10 days. MAIN OUTCOMES AND MEASURES The primary outcome was organ support–free days, a composite of hospital survival and days alive without cardiovascular or respiratory organ support through 21 days. The primary analysis was a bayesian cumulative logistic model. Odds ratios (ORs) greater than 1 represent improved outcomes. RESULTS On February 25, 2022, enrollment was discontinued due to safety concerns. Among 679 critically ill patients with available primary outcome data, the median age was 56 years and 239 participants (35.2%) were women. Median (IQR) organ support–free days among critically ill patients was 10 (–1 to 16) in the ACE inhibitor group (n = 231), 8 (–1 to 17) in the ARB group (n = 217), and 12 (0 to 17) in the control group (n = 231) (median adjusted odds ratios of 0.77 [95% bayesian credible interval, 0.58-1.06] for improvement for ACE inhibitor and 0.76 [95% credible interval, 0.56-1.05] for ARB compared with control). The posterior probabilities that ACE inhibitors and ARBs worsened organ support–free days compared with control were 94.9% and 95.4%, respectively. Hospital survival occurred in 166 of 231 critically ill participants (71.9%) in the ACE inhibitor group, 152 of 217 (70.0%) in the ARB group, and 182 of 231 (78.8%) in the control group (posterior probabilities that ACE inhibitor and ARB worsened hospital survival compared with control were 95.3% and 98.1%, respectively). CONCLUSIONS AND RELEVANCE In this trial, among critically ill adults with COVID-19, initiation of an ACE inhibitor or ARB did not improve, and likely worsened, clinical outcomes. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT0273570

    Characterization of neonates born to mothers with SARS-CoV-2 infection: review and meta-analysis

    No full text
    Characterization of neonates born to mothers with SARS-CoV-2 infection has been partially carried out. There has been no systematic review providing a holistic neonatal presentation including possible vertical transmission. A systematic literature search was performed using PubMed, Google Scholar and Web of Science up to June, 6 2020. Studies on neonates born to mothers with SARS-CoV-2 infection were included. A binary random effect model was used for prevalence and 95% confidence interval. 32 studies involving 261 neonates were included in meta-analysis. Most neonates born to infected mothers did not show any clinical abnormalities (80.4%). Clinical features were dyspnea in 11 (42.3%) and fever in 9 newborns (19.1%). Of 261 neonates, 120 neonates were tested for infection, of whom 12 (10.0%) tested positive. Swabs from placenta, cord blood and vaginal secretion were negative. Neonates are mostly non affected by the mother's SARS-CoV-2 infection. The risk of vertical transmission is low

    The visually estimated blood volume in scaled canisters based on a simulation study

    No full text
    Background: The most common technique used worldwide to quantify blood loss during an operation is the visual assessment by the attending intervention team. In every operating room you will find scaled suction canisters that collect fluids from the surgical field. This scaling is commonly used by clinicians for visual assessment of intraoperative blood loss. While many studies have been conducted to quantify and improve the inaccuracy of the visual estimation method, research has focused on the estimation of blood volume in surgical drapes. The question whether and how scaling of canisters correlates with actual blood loss and how accurately clinicians estimate blood loss in scaled canisters has not been the focus of research to date. Methods: A simulation study with four “bleeding” scenarios was conducted using expired whole blood donations. After diluting the blood donations with full electrolyte solution, the sample blood loss volume (SBL) was transferred into suction canisters. The study participants then had to estimate the blood loss in all four scenarios. The difference to the reference blood loss (RBL) per scenario was analyzed. Results: Fifty-three anesthetists participated in the study. The median estimated blood loss was 500 ml (IQR 300/1150) compared to the RBL median of 281.5 ml (IQR 210.0/1022.0). Overestimations up to 1233 ml were detected. Underestimations were also observed in the range of 138 ml. The visual estimate for canisters correlated moderately with RBL (Spearman’s rho: 0.818; p < 0.001). Results from univariate nonparametric confirmation statistics regarding visual estimation of canisters show that the deviation of the visual estimate of blood loss is significant (z = − 10.95, p < 0.001, n = 220). Participants’ experience level had no significant influence on VEBL (p = 0.402). Conclusion: The discrepancies between the visual estimate of canisters and the actual blood loss are enormous despite the given scales. Therefore, we do not recommend estimating the blood loss visually in scaled suction canisters. Colorimetric blood loss estimation could be a more accurate option

    Low coherence interferometry in selective laser melting

    Get PDF
    © 2014 The Authors. Published by Elsevier B.V. Selective Laser Melting (SLM) is an additive layer manufacturing technology that offers several advantages compared to conventional methods of production such as an increased freedom of design and a toolless production suited for variable lot sizes. Despite these attractive aspects today's state of the art SLM machines lack a holistic process monitoring system that detects and records typical defects during production. A novel sensor concept based on the low coherence interferometry (LCI) was integrated into an SLM production setup. The sensor is mounted coaxially to the processing laser beam and is capable of sampling distances along the optical axis. Measurements during and between the processing of powder layers can reveal crucial topology information which is closely related to the final part quality. The overall potential of the sensor in terms of quality assurance and process control is being discussed. Furthermore fundamental experiments were performed to derive the performance of the system

    Independent risk factors for RBC transfusion in children undergoing surgery. Analysis of 14,248 cases at a German university hospital

    No full text
    Background: paediatric patients are vulnerable to blood loss and even a small loss of blood can be associated with severe shock. In emergency situations, a red blood cell (RBC) transfusion may become unavoidable, although it is associated with various risks. The aim of this trial was to identify independent risk factors for perioperative RBC transfusion in children undergoing surgery. Methods: to identify independent risk factors for perioperative RBC transfusion in children undergoing surgery and to access RBC transfusion rates and in-hospital outcomes (e.g., length of stay, mortality, and typical postoperative complication rates), a monocentric, retrospective, and observational study was conducted. Descriptive, univariate, and multivariate analyses were performed. Results: between 1 January 2010 and 31 December 2019, data from n = 14,248 cases were identified at the centre. Analysis revealed an RBC transfusion rate of 10.1% (n = 1439) in the entire cohort. The independent predictors of RBC transfusion were the presence of preoperative anaemia (p < 0.001; OR = 15.10 with preoperative anaemia and OR = 2.40 without preoperative anaemia), younger age (p < 0.001; ORs between 0.14 and 0.28 for children older than 0 years), female gender (p = 0.036; OR = 1.19 compared to male gender), certain types of surgery (e.g., neuro surgery (p < 0.001; OR = 10.14), vascular surgery (p < 0.001; OR = 9.93), cardiac surgery (p < 0.001; OR = 4.79), gynaecology (p = 0.014; OR = 3.64), visceral surgery (p < 0.001; OR = 2.48), and the presence of postoperative complications (e.g., sepsis (p < 0.001; OR = 10.16), respiratory dysfunction (p < 0.001; OR = 7.56), cardiovascular dysfunction (p < 0.001; OR = 4.68), neurological dysfunction (p = 0.029; OR = 1.77), and renal dysfunction (p < 0.001; OR = 16.17)). Conclusion: preoperative anaemia, younger age, female gender, certain types of surgery, and postoperative complications are independent predictors for RBC transfusion in children undergoing surgery. Future prospective studies are urgently required to identify, in detail, the potential risk factors and impact of RBC transfusion in children

    Safety and Efficiency of Low-Dose Spinal Analgesia Compared to Epidural Analgesia in Treatment of Pain during Labour: A Case Control Study

    No full text
    Background: The epidural catheter for analgesia has been used for decades and has become the gold standard in pain therapy for pregnant women in labour. However, procedural parameters such as time to pain relief and duration to implementation pose hurdles for patients shortly before delivery. Low-dose spinal analgesia (LDSA) is an alternative procedure that was investigated in the study with regard to patient satisfaction and complication rates compared to epidural catheter. Methods: In a retrospective monocentric study, a total of 242 patients receiving low-dose spinal analgesia or epidural catheters were evaluated using propensity score matching. Subjective patient satisfaction as well as complication rates were primarily analysed. We hypothesise that LDSA is a safe procedure and provides a similar level of satisfaction compared with the epidural catheter. For this purpose, both procedures were performed according to in-house standards and the patients were interviewed afterwards. Patients who required surgical delivery were excluded to prevent bias. Results: The LDSA was rated on average as very good [1.09 ± 0.311 vs. 1.07 ± 0.431] in terms of satisfaction by the patients compared to the epidural catheter without showing a significant difference (p = 0.653). Complications were in the low single-digit non-significant range for both procedures [6 (5%) vs. 7 (6%); p = 0.776]. The evaluation showed more perineal tears I° and II° in the low-dose spinal analgesia group [I°: 28 (23%) vs. 3 (2%); p p p = 0.005]. Conclusions: LDSA represents a low complication procedure for patients at the end of labour with a high satisfaction level. With the LDSA in the repertoire of pain relief during childbirth, it is possible to also achieve pain reduction for women with deliveries of high velocity without compromising patient satisfaction or perinatal morbidity
    corecore