73 research outputs found

    Immunoarchitecture of the Regenerating Rat Spleen: Effects of Partial Splenectomy and Heterotopic Autotransplantation

    Get PDF
    To investigate the microstructure of in situ (eutopic) and autotransplanted (ectopic) splenic remnants, adult Sprague-Dawley rats were studied 60 days after 1) subtotal (~80%) splenectomy, 2) total splenectomy followed by single or multiple remnant intraperitoneal autotransplantation, or 3) sham operation. Total nucleated cell counts were determined in excised splenic remnants, and immunohistochemical staining using monoclonal antibodies to rat B-and T-cell antigens was performed in serial tissue sections. Immunoarchitecture of eutopic remnants was indistinguishable from that of intact spleens and total nucleated cell counts remained proportional to weight. In contrast, ectopic remnants showed sparsity and abnormal mixing of B and T lymphocyte subpopulations with widespread loss of follicles and periarteriolar lymphoid sheaths in addition to lower density and marked reduction of total nucleated cells. These findings provide immunohistologic evidence that preservation of intact vasculature is critical to splenic architecture, which may account in part for the demonstrable functional inferiority of ectopic remnants

    Safety of intravenous ferric carboxymaltose versus oral iron in patients with nondialysis-dependent CKD: an analysis of the 1-year FIND-CKD trial.

    Get PDF
    Background: The evidence base regarding the safety of intravenous (IV) iron therapy in patients with chronic kidney disease (CKD) is incomplete and largely based on small studies of relatively short duration. Methods: FIND-CKD (ClinicalTrials.gov number NCT00994318) was a 1-year, open-label, multicenter, prospective study of patients with nondialysis-dependent CKD, anemia and iron deficiency randomized (1:1:2) to IV ferric carboxymaltose (FCM), targeting higher (400-600 µg/L) or lower (100-200 µg/L) ferritin, or oral iron. A post hoc analysis of adverse event rates per 100 patient-years was performed to assess the safety of FCM versus oral iron over an extended period. Results: The safety population included 616 patients. The incidence of one or more adverse events was 91.0, 100.0 and 105.0 per 100 patient-years in the high ferritin FCM, low ferritin FCM and oral iron groups, respectively. The incidence of adverse events with a suspected relation to study drug was 15.9, 17.8 and 36.7 per 100 patient-years in the three groups; for serious adverse events, the incidence was 28.2, 27.9 and 24.3 per 100 patient-years. The incidence of cardiac disorders and infections was similar between groups. At least one ferritin level ≥800 µg/L occurred in 26.6% of high ferritin FCM patients, with no associated increase in adverse events. No patient with ferritin ≥800 µg/L discontinued the study drug due to adverse events. Estimated glomerular filtration rate remained the stable in all groups. Conclusions: These results further support the conclusion that correction of iron deficiency anemia with IV FCM is safe in patients with nondialysis-dependent CKD

    Second flip in the Hassett-Keel program: a local description

    No full text
    This is the first of three papers in which we give a moduli interpretation of the second flip in the log minimal model program for , replacing the locus of curves with a genus Weierstrass tail by a locus of curves with a ramphoid cusp. In this paper, for , we introduce new -stability conditions for curves and prove that they are deformation open. This yields algebraic stacks related by open immersions . We prove that around a curve corresponding to a closed point in , these open immersions are locally modeled by variation of geometric invariant theory for the action of on the first-order deformation space of C

    Relationship among Length of Facility Ownership, Clinical Performance, and Mortality

    No full text
    Background and objectives: The association between level of performance in achieving guideline-recommended clinical indicators and relative reduction in patient mortality is inconsistent among large dialysis organizations (LDOs). Because growth rates among providers differ, we reasoned that clinical performance and mortality rates in dialysis facilities may be related to length of facility ownership
    • …
    corecore