309 research outputs found
A comparison of balloon injury models of endovascular lesions in rat arteries
BACKGROUND: Balloon injury (BI) of the rat carotid artery (CCA) is widely used to study intimal hyperplasia (IH) and decrease in lumen diameter (LD), but CCA's small diameter impedes the evaluation of endovascular therapies. Therefore, we validated BI in the aorta (AA) and iliac artery (CIA) to compare it with CCA. METHODS: Rats underwent BI or a sham procedure (control). Light microscopic evaluation was performed either directly or at 1, 2, 3, 4 and 16 weeks follow-up. The area of IH and the change in LD (LD at 16 weeks minus LD post BI) were compared. RESULTS: In the BI-groups the area of IH increased to 0.14 ± 0.08 mm(2) (CCA), 0.14 ± 0.03 mm(2) (CIA) and 0.12 ± 0.04 mm(2) (AA) at 16 weeks (NS). The LD decreased with 0.49 ± 0.07 mm (CCA), compared to 0.22 ± 0.07 mm (CIA) and 0.07 ± 0.10 mm (AA) at 16 weeks (p < 0.05). The constrictive vascular remodelling (CVR = wall circumference loss combined with a decrease in LD) was -0.17 ± 0.05 mm in CIA but absent in CCA and AA. No IH, no decrease in LD and no CVR was seen in the control groups. CONCLUSIONS: BI resulted in: (1.) a decrease in LD in CCA due to IH, (2.) a decrease in LD in CIA due to IH and CVR, (3.) no change in LD in AA, (4.) Comparable IH development in all arteries, (5.) CCA has no vasa vasorum compared to CIA and AA, (6.) The CIA model combines good access for 2 F endovascular catheters with a decrease in LD due to IH and CVR after BI
The free surface of superfluid 4He at zero temperature
The structure and energetics of the free surface of superfluid He are
studied using the diffusion Monte Carlo method. Extending a previous
calculation by Vall\'es and Schmidt, which used the Green's function Monte
Carlo method, we study the surface of liquid He within a slab geometry
using a larger number of particles in the slab and an updated interatomic
potential. The surface tension is accurately estimated from the energy of slabs
of increasing surface density and its value is close to one of the two existing
experimental values. Results for the density profiles allow for the calculation
of the surface width which shows an overall agreement with recent experimental
data. The dependence on the transverse direction to the surface of other
properties such as the two-body radial distribution function, structure factor,
and one-body density matrix is also studied. The condensate fraction, extracted
from the asymptotic behavior of the one-body density matrix, shows an
unambiguous enhancement when approaching the surface.Comment: RevTex, 11 pages, accepted in Phys. Rev.
Discrimination of intravascular lumen and dissections in single intravascular ultrasound images using subtraction, conventional averaging and saline flush
With current 30-MHz intravascular ultrasound systems, flowing blood may cause considerable backscatter which in real-time images is characterized by dynamic speckle. However, in a single intravascular ultrasound image (still-frame) the discrimination between arterial lumen and wall may be difficult due to the frozen intraluminal speckle, particularly in the presence of dissections. We compared subtraction, averaging and saline flush as methods to improve the discrimination between arterial lumen and wall in a single image. The real-time images served as gold standard. In 22 patients who underwent peripheral balloon angioplasty, ultrasound images obtained from 84 sites were examined. The sensitivity and specificity of detecting dissections were in the subtraction image 85% and 100%, in the averaged image 57% and 96%, and in the saline flush image 58% and 86%, respectively. Subtraction is a promising method to outline the irregular lumen in a single image
Intravascular ultrasound predictors of outcome after peripheral balloon angioplasty
Objective:This study investigates the potential role of intravascular ultrasound (IVUS) in the outcome in patients undergoing percutaneous transluminal angioplasty (PTA) of the superficial femoral artery.Materials:Angiographic and the qualitative and quantitative IVUS data obtained at the narrowest site derived from 39 patients before and after PTA were analysed.Results:Angiographically the diameter of the remaining stenosis seen after PTA was classified as < 50% in 31 patients (success); in eight patients a failure was encountered. Evaluating at 6 months the functional and anatomic results of the PTA in 31 patients, the intervention was a success in 14 patients (Group I) and a failure in 17 patients (Group II). The remaining eight patients defined as angiographic failure following PTA comprised Group III. Neither qualitative nor quantitative IVUS data obtained before PTA could predict outcome. Conversely, after PTA, the extent of dissection was significantly more severe in Groups II and III than in Group I. Similarly, significant differences were found between Groups I and II for mean free lumen area (13.2 vs. 9.7 mm2, respectively) and mean free lumen diameter (4.1 vs. 3.5 mm, respectively). Quantitative data obtained in Group II were similar to those in Group III.Conclusion:This preliminary study demonstrates that following PTA the extent of dissection, free lumen area and diameter seen with IVUS are predictive factors of patency. Future studies with more patients are mandatory to further highlight the sensitivity of these observations
Additional surgical procedures and perioperative morbidity in post-chemotherapy retroperitoneal lymph node dissection for metastatic testicular cancer in two intermediate volume hospitals
Purpose: To evaluate the perioperative morbidity of PC-RPLND in two intermediate volume centers and to identify predictors of high morbidity. Methods: Retrospective analysis of 124 patients treated with open PC-RPLND at two tertiary referral centers between 2001 and 2018. Perioperative morbidity was determined by analyzing additional surgical procedures, intra-operative blood loss, and postoperative complications. Results: An additional procedure was necessary for 33 patients (26.6%). The risk was higher in patients with IGCCCG intermediate/poor prognosis (OR 3.56; 95% CI 1.33–9.52) and residual tumor size > 5 cm (OR 3.53; 95% CI 1.39–8.93). Blood loss was higher in patients with IGCCCG intermediate/poor prognosis (β = 0.177; p = 0.029), large residual tumor (β = 0.570; p < 0.001), an additional intervention (β = 0.342; p < 0.001) and teratoma on retroperitoneal histology (β = − 0.19; p = 0.014). Thirty-one patients had a postoperative complication Clavien-Dindo Grade ≥ 2 (25.0%). Complication risk was highest in patients undergoing an additional intervention (OR 3.46; 95% CI 1.03–11.60; p = 0.044). Conclusions: The rate of additional interventions in our series is comparable to what has been reported in high-volume centers. IGCCCG intermediate/poor prognosis patients with high-volume disease and patients undergoing an additional surgical procedure can be classified as high-risk patients
Traits and stress: keys to identify community effects of low levels of toxicants in test systems
Community effects of low toxicant concentrations are obscured by a multitude of confounding factors. To resolve this issue for community test systems, we propose a trait-based approach to detect toxic effects. An experiment with outdoor stream mesocosms was established 2-years before contamination to allow the development of biotic interactions within the community. Following pulse contamination with the insecticide thiacloprid, communities were monitored for additional 2 years to observe long-term effects. Applying a priori ecotoxicological knowledge species were aggregated into trait-based groups that reflected stressor-specific vulnerability of populations to toxicant exposure. This reduces inter-replicate variation that is not related to toxicant effects and enables to better link exposure and effect. Species with low intrinsic sensitivity showed only transient effects at the highest thiacloprid concentration of 100 μg/l. Sensitive multivoltine species showed transient effects at 3.3 μg/l. Sensitive univoltine species were affected at 0.1 μg/l and did not recover during the year after contamination. Based on these results the new indicator SPEARmesocosm was calculated as the relative abundance of sensitive univoltine taxa. Long-term community effects of thiacloprid were detected at concentrations 1,000 times below those detected by the PRC (Principal Response Curve) approach. We also found that those species, characterised by the most vulnerable trait combination, that were stressed were affected more strongly by thiacloprid than non-stressed species. We conclude that the grouping of species according to toxicant-related traits enables identification and prediction of community response to low levels of toxicants and that additionally the environmental context determines species sensitivity to toxicants
Candida glabrata : a review of its features and resistance
Candida species belong to the normal microbiota of the oral cavity and gastrointestinal and vaginal tracts, and are responsible for several clinical manifestations, from mucocutaneous overgrowth to bloodstream infections. Once believed to be non-pathogenic, Candida glabrata was rapidly blamable for many human diseases. Year after year, these pathological circumstances are more recurrent and problematic to treat, especially when patients reveal any level of immunosuppression. These difficulties arise from the capacity of C. glabrata to form biofilms and also from its high resistance to traditional antifungal therapies. Thus, this review intends to present an excerpt of the biology, epidemiology, and pathology of C. glabrata, and detail an approach to its resistance mechanisms based on studies carried out up to the present.The authors are grateful to strategic project PTDC/SAU-MIC/119069/2010 for the financial support to the research center and for Celia F. Rodrigues' grant
Measurement of the Tau Lepton Polarisation at LEP2
A first measurement of the average polarisation P_tau of tau leptons produced in e+e- annihilation at energies significantly above the Z resonance is presented. The polarisation is determined from the kinematic spectra of tau hadronic decays. The measured value P_tau = -0.164 +/- 0.125 is consistent with the Standard Model prediction for the mean LEP energy of 197 GeV.A first measurement of the average polarisation Pτ of tau leptons produced in e + e − annihilation at energies significantly above the Z resonance is presented. The polarisation is determined from the kinematic spectra of tau hadronic decays. The measured value Pτ=−0.164±0.125 is consistent with the Standard Model prediction for the mean LEP energy of 197 GeV.A first measurement of the average polarisation P_tau of tau leptons produced in e+e- annihilation at energies significantly above the Z resonance is presented. The polarisation is determined from the kinematic spectra of tau hadronic decays. The measured value P_tau = -0.164 +/- 0.125 is consistent with the Standard Model prediction for the mean LEP energy of 197 GeV
- …