288 research outputs found
A comprehensive fracture prevention strategy in older adults : The European union geriatric medicine society (EUGMS) statement
Published also in Aging Clinical and Experimental Research, Vol.28, No.4, WOS: 000379034800030Prevention of fragility fractures in older people has become a public health priority, although the most appropriate and cost-effective strategy remains unclear. In the present statement, the Interest group on falls and fracture prevention of the European union geriatric medicine society (EUGMS), in collaboration with the International association of gerontology and geriatrics for the European region (IAGG-ER), the European union of medical specialists (EUMS), the Fragility fracture network (FFN), the International osteoporosis foundation (IOF) - European society for clinical and economic aspects of osteoporosis and osteoarthritis (ECCEO), outlines its views on the main points in the current debate in relation to the primary and secondary prevention of falls, the diagnosis and treatment of bone fragility, and the place of combined falls and fracture liaison services for fracture prevention in older people. (C) 2016 Published by Elsevier Masson SAS.Peer reviewe
A comprehensive fracture prevention strategy in older adults: The European union geriatric medicine society (EUGMS) statement
Prevention of fragility fractures in older people has become a public health priority, although the most appropriate and cost-effective strategy remains unclear. In the present statement, the Interest group on falls and fracture prevention of the European union geriatric medicine society (EUGMS), in collaboration with the International association of gerontology and geriatrics for the European region (IAGG-ER), the European union of medical specialists (EUMS), the Fragility fracture network (FFN), the International osteoporosis foundation (IOF) – European society for clinical and economic aspects of osteoporosis and osteoarthritis (ECCEO), outlines its views on the main points in the current debate in relation to the primary and secondary prevention of falls, the diagnosis and treatment of bone fragility, and the place of combined falls and fracture liaison services for fracture prevention in older people
Genome-wide association study identifies 32 novel breast cancer susceptibility loci from overall and subtype-specific analyses.
Breast cancer susceptibility variants frequently show heterogeneity in associations by tumor subtype1-3. To identify novel loci, we performed a genome-wide association study including 133,384 breast cancer cases and 113,789 controls, plus 18,908 BRCA1 mutation carriers (9,414 with breast cancer) of European ancestry, using both standard and novel methodologies that account for underlying tumor heterogeneity by estrogen receptor, progesterone receptor and human epidermal growth factor receptor 2 status and tumor grade. We identified 32 novel susceptibility loci (P < 5.0 × 10-8), 15 of which showed evidence for associations with at least one tumor feature (false discovery rate < 0.05). Five loci showed associations (P < 0.05) in opposite directions between luminal and non-luminal subtypes. In silico analyses showed that these five loci contained cell-specific enhancers that differed between normal luminal and basal mammary cells. The genetic correlations between five intrinsic-like subtypes ranged from 0.35 to 0.80. The proportion of genome-wide chip heritability explained by all known susceptibility loci was 54.2% for luminal A-like disease and 37.6% for triple-negative disease. The odds ratios of polygenic risk scores, which included 330 variants, for the highest 1% of quantiles compared with middle quantiles were 5.63 and 3.02 for luminal A-like and triple-negative disease, respectively. These findings provide an improved understanding of genetic predisposition to breast cancer subtypes and will inform the development of subtype-specific polygenic risk scores
The LHCb upgrade I
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software
The ALICE experiment at the CERN LHC
ALICE (A Large Ion Collider Experiment) is a general-purpose, heavy-ion detector at the CERN LHC which focuses on QCD, the strong-interaction sector of the Standard Model. It is designed to address the physics of strongly interacting matter and the quark-gluon plasma at extreme values of energy density and temperature in nucleus-nucleus collisions. Besides running with Pb ions, the physics programme includes collisions with lighter ions, lower energy running and dedicated proton-nucleus runs. ALICE will also take data with proton beams at the top LHC energy to collect reference data for the heavy-ion programme and to address several QCD topics for which ALICE is complementary to the other LHC detectors. The ALICE detector has been built by a collaboration including currently over 1000 physicists and engineers from 105 Institutes in 30 countries. Its overall dimensions are 161626 m3 with a total weight of approximately 10 000 t. The experiment consists of 18 different detector systems each with its own specific technology choice and design constraints, driven both by the physics requirements and the experimental conditions expected at LHC. The most stringent design constraint is to cope with the extreme particle multiplicity anticipated in central Pb-Pb collisions. The different subsystems were optimized to provide high-momentum resolution as well as excellent Particle Identification (PID) over a broad range in momentum, up to the highest multiplicities predicted for LHC. This will allow for comprehensive studies of hadrons, electrons, muons, and photons produced in the collision of heavy nuclei. Most detector systems are scheduled to be installed and ready for data taking by mid-2008 when the LHC is scheduled to start operation, with the exception of parts of the Photon Spectrometer (PHOS), Transition Radiation Detector (TRD) and Electro Magnetic Calorimeter (EMCal). These detectors will be completed for the high-luminosity ion run expected in 2010. This paper describes in detail the detector components as installed for the first data taking in the summer of 2008
Comparison of inhalation technique with the Diskus and Autohaler in asthmatic children at home
Objective: Asthma is the most common chronic disease in childhood and anti-inflammatory medication is the cornerstone of treatment. Inhalers are frequently used incorrectly when demonstrated in the hospital, suggesting poor technique at home. We aimed to 1) compare daily inhalation technique with the Diskus and Autohaler in asthmatic children by filming inhalations at home and 2) compare daily inhalation technique with technique demonstrated in the hospital. Methods: We performed a randomised study in asthmatic children (aged 6–18 years) from the outpatient clinic of Medisch Spectrum Twente hospital (Enschede, The Netherlands) from July 2014 to April 2016. Children received inhalation instructions for the Diskus and Autohaler and were randomised to use one device in the morning and the other in the evening. During the 28-day study period, inhalations were filmed at home and subsequently demonstrated in the hospital. All inhalations were checked for seven critical errors per device. Results: 636 videos with the Diskus and 663 with the Autohaler were provided by 27 children. The most common critical error in daily life was an incorrect device position during preparation of the Diskus (n=271) and an insufficiently deep inhalation (n=39) using the Autohaler. Percentage of correct days using the Diskus was 44%, compared to 96% with the Autohaler (p<0.001). The two most common errors with the Diskus were made at least twice as often at home than in the hospital. Conclusion: Inhalation technique at home was markedly better with the Autohaler than with the Diskus. Paediatricians should be aware that hospital-based demonstrations can overestimate daily inhalation technique with the Diskus
- …