37 research outputs found

    Low secondary electron yield engineered surface for electron cloud mitigation

    Get PDF
    Secondary electron yield (SEY or δ) limits the performance of a number of devices. Particularly, in high-energy charged particle accelerators, the beam-induced electron multipacting is one of the main sources of electron cloud (e-cloud) build up on the beam path; in radio frequency wave guides, the electron multipacting limits their lifetime and causes power loss; and in detectors, the secondary electrons define the signal background and reduce the sensitivity. The best solution would be a material with a low SEY coating and for many applications δ < 1 would be sufficient. We report on an alternative surface preparation to the ones that are currently advocated. Three commonly used materials in accelerator vacuum chambers (stainless steel, copper, and aluminium) were laser processed to create a highly regular surface topography. It is shown that this treatment reduces the SEY of the copper, aluminium, and stainless steel from δmax of 1.90, 2.55, and 2.25 to 1.12, 1.45, and 1.12, respectively. The δmax further reduced to 0.76-0.78 for all three treated metals after bombardment with 500 eV electrons to a dose between 3.5 × 10-3 and 2.0 × 10-2 C·mm-2

    Recent RHIC in-situ coating technology developments

    Full text link
    To rectify the problems of electron clouds observed in RHIC and unacceptable ohmic heating for superconducting magnets that can limit future machine upgrades, we started developing a robotic plasma deposition technique for insituin-situ coating of the RHIC 316LN stainless steel cold bore tubes based on staged magnetrons mounted on a mobile mole for deposition of Cu followed by amorphous carbon (a-C) coating. The Cu coating reduces wall resistivity, while a-C has low SEY that suppresses electron cloud formation. Recent RF resistivity computations indicate that 10 {\mu}m of Cu coating thickness is needed. But, Cu coatings thicker than 2 {\mu}m can have grain structures that might have lower SEY like gold black. A 15-cm Cu cathode magnetron was designed and fabricated, after which, 30 cm long samples of RHIC cold bore tubes were coated with various OFHC copper thicknesses; room temperature RF resistivity measured. Rectangular stainless steel and SS discs were Cu coated. SEY of rectangular samples were measured at room; and, SEY of a disc sample was measured at cryogenic temperatures.Comment: 8 pages, contribution to the Joint INFN-CERN-EuCARD-AccNet Workshop on Electron-Cloud Effects: ECLOUD'12; 5-9 Jun 2012, La Biodola, Isola d'Elba, Ital

    Beam-induced backgrounds measured in the ATLAS detector during local gas injection into the LHC beam vacuum

    Get PDF

    Gamma Factory at CERN – novel research tools made of light

    Get PDF
    We discuss the possibility of creating novel research tools by producing and storing highly relativistic beams of highly ionised atoms in the CERN accelerator complex, and by exciting their atomic degrees of freedom with lasers to produce high-energy photon beams. Intensity of such photon beams would be by several orders of magnitude higher than offered by the presently operating light sources, in the particularly interesting gamma-ray energy domain of 0.1-400 MeV. In this energy range, the high-intensity photon beams can be used to produce secondary beams of polarised electrons, polarised positrons, polarised muons, neutrinos, neutrons and radioactive ions. New research opportunities in a wide domain of fundamental and applied physics can be opened by the Gamma Factory scientific programme based on the above primary and secondary beams.Comment: 12 pages; presented by W. Placzek at the XXV Cracow Epiphany Conference on Advances in Heavy Ion Physics, 8-11 January 2019, Cracow, Polan

    Beam-induced backgrounds measured in the ATLAS detector during local gas injection into the LHC beam vacuum

    Get PDF
    Inelastic beam-gas collisions at the Large Hadron Collider (LHC), within a few hundred metres of the ATLAS experiment, are known to give the dominant contribution to beam backgrounds. These are monitored by ATLAS with a dedicated Beam Conditions Monitor (BCM) and with the rate of fake jets in the calorimeters. These two methods are complementary since the BCM probes backgrounds just around the beam pipe while fake jets are observed at radii of up to several metres. In order to quantify the correlation between the residual gas density in the LHC beam vacuum and the experimental backgrounds recorded by ATLAS, several dedicated tests were performed during LHC Run 2. Local pressure bumps, with a gas density several orders of magnitude higher than during normal operation, were introduced at different locations. The changes of beam-related backgrounds, seen in ATLAS, are correlated with the local pressure variation. In addition the rates of beam-gas events are estimated from the pressure measurements and pressure bump profiles obtained from calculations. Using these rates, the efficiency of the ATLAS beam background monitors to detect beam-gas events is derived as a function of distance from the interaction point. These efficiencies and characteristic distributions of fake jets from the beam backgrounds are found to be in good agreement with results of beam-gas simulations performed with theFluka Monte Carlo programme

    Characterization of Carbon Coatings with Low Secondary Electron Yield

    Full text link
    Amorphous carbon (a-C) coatings can reliably be produced with a maximum secondary electron yield (SEY) close to 1 at room temperature. Measurements at low temperature (LHe) are in progress. Analysis by X-ray Photoemission Spectroscopy (XPS) shows a correlation between the lineshape of C1s spectrum in XPS and the maximum SEY of the investigated samples. The initial level of oxygen on the surface of the various samples does not seem to be related to the initial maximum SEY value. However, the increase of the SEY with air exposure time on each individual sample is related to the amount of oxygen containing adsorbates. Storage in different environments has been investigated (static vacuum, aluminium foil, dry nitrogen and desiccators), and shows significant differences in the “aging” behaviour. Aging is very moderate when storing samples wrapped in aluminium foil in air. Samples which have undergone aging due to inappropriate storage can be recovered nearly to the initial value of their SEY by surface treatments such as conditioning by electron beam, annealing under vacuum and ion bombardment. However, an enhanced sensitivity to air exposure is observed for most of these curing methods
    corecore