40 research outputs found

    Mathematical models for description of hydrodynamics, mass and heat transfer in microreactor systems

    Get PDF
    Over the last decades the increased use of microreactors in all types of industries is observed. This phenomenon is based on the advantages that the microreactor systems can achieve in term of better process control, more efficient heat transfer and handling of hazardous chemicals. During this time mathematical models that describe flow inside microchannels have emerged ranging from Navier-Stokes equations to simplified mathematical models for laminar and segmented flows. The aim of this review is to present current studies in term of mathematical models that are nowadays commonly used for the description of hydrodynamics, mass and heat transfer in microreactor systems

    NEAR INFRARED SPECTROSCOPY (NIRS) AS FOOD QUALITY AND FOOD FRAUD DETECTOR – APPLIED ON FISH STICKS

    Get PDF
    The aim of this study was to present the professional application of near infrared spectroscopy (NIRs) in the detection of food quality on purchased fish sticks. The measured NIR spectra of samples prepared from fish or squid were related to nutritional labels such as the amount of certain macronutrient and the proportion of the starting material (fish/squid). In the standard procedure, NIRs coupled with chemometric tools such as principal component analysis (PCA) and partial least square regression (PLSR) was used to investigate the qualitative and/or quantitative capabilities in determining food quality. Excellent qualitative differentiation was achieved with PCA, with biplots showing how the explanation of variation increased from 80.12 % when only nutritional information was used in the observation to 96.89% when nutritional information was coupled with the corresponding NIR spectrum. Since higher levels of animal protein in food are associated with an increase in price, the detection probabilities of different protein sources (fish/meat) were tested using PLSR, with 100% of the samples successfully detected. PLSR was also used to detect the correlation of the NIR spectra to the macronutrient contents and the strongest correlation was determined for proteins (R2 = 0.99). The results confirmed the feasibility of using NIRs in the qualitative evaluation of samples where it is possible to determine the predominance of fish or squid, and also to estimate the expected protein content. The protein content is related to the price of the product, since all products containing animal proteins have higher prices that grow proportionally to their share. NIRs is not a qualitative method, but it can help in the selection of products, whose exact composition and possible adulteration can be confirmed by additional laboratory analysis

    NEAR INFRARED SPECTROSCOPY (NIRS) AS FOOD QUALITY AND FOOD FRAUD DETECTOR – APPLIED ON FISH STICKS

    Get PDF
    The aim of this study was to present the professional application of near infrared spectroscopy (NIRs) in the detection of food quality on purchased fish sticks. The measured NIR spectra of samples prepared from fish or squid were related to nutritional labels such as the amount of certain macronutrient and the proportion of the starting material (fish/squid). In the standard procedure, NIRs coupled with chemometric tools such as principal component analysis (PCA) and partial least square regression (PLSR) was used to investigate the qualitative and/or quantitative capabilities in determining food quality. Excellent qualitative differentiation was achieved with PCA, with biplots showing how the explanation of variation increased from 80.12 % when only nutritional information was used in the observation to 96.89% when nutritional information was coupled with the corresponding NIR spectrum. Since higher levels of animal protein in food are associated with an increase in price, the detection probabilities of different protein sources (fish/meat) were tested using PLSR, with 100% of the samples successfully detected. PLSR was also used to detect the correlation of the NIR spectra to the macronutrient contents and the strongest correlation was determined for proteins (R2 = 0.99). The results confirmed the feasibility of using NIRs in the qualitative evaluation of samples where it is possible to determine the predominance of fish or squid, and also to estimate the expected protein content. The protein content is related to the price of the product, since all products containing animal proteins have higher prices that grow proportionally to their share. NIRs is not a qualitative method, but it can help in the selection of products, whose exact composition and possible adulteration can be confirmed by additional laboratory analysis

    The Smaller, The Better - Microtechnology for a Macroresults

    Get PDF
    There is a well-known expression The Bigger, The Better, on which many would agree but when it comes to microreac- tors it is necessary to make the slight modification and say The Smaller, The Better. Reduction in reactor size emerged in many positive effects on many chemical and biochemical reactions. Faster reactions, smaller usage of reaction com- ponents, smaller amount of waste streams, safer reaction conditions, easier process manipulation etc. are just some of the advantages of microreactors. The aim of this review is to present microreactor technology in a simple way and to show its basic characteristics such as structure, advantages and disadvantages, types and general application

    Application of NIR spectroscopy in gluten detection as a cross-contaminant in food

    Get PDF
    The determination of gluten is of critical importance when food screening is intended for special groups such as food ingredient intolerant and allergic persons. Cross-contamination of food that does not contain gluten is also possible in the sales chain. The aim of this study was to determine the applicability of Near-Infrared Spectroscopy (NIRs) for the detection of gluten traces in rice, rice flour, corn flour and corn grits. In the cross-contamination simulation, two types of wheat flour were used. They were added to rice, rice flour, corn flour and corn grits in a range from 5 % to 30 %. Apart from the spectra of pure and contaminated samples, conductivity and total dissolved solids were monitored to determine changes in the samples. NIR spectroscopy was combined with chemometric techniques to determine at which wavelengths a glutenfree fingerprint can be detected. Although experiments were carried out with a NIR instrument that monitors molecular vibrations in the range of λ= 904-1699 nm, the gluten fingerprint was successfully determined, regardless of the type of flour that was added to the rice, rice flour, corn flour and corn grits. All concentrations of the added flours were successfully determined and models were developed to detect the concentrations of the added flours. Even the conductivity showed good prediction potential in gluten determination. Regardless if the investigated samples were contaminated or not, the determination coefficient R2 was over 0.9. Developed models could be used to predict possible wheat flour contamination of any rice or corn product samples or samples prepared for cooking in water

    OPTIMIZATION OF ETHANOL/WATER SOLVENT EXTRACTION OF BIOACTIVE COMPONENTS ORIGINATING FROM INDUSTRIAL HEMP (Cannabis sativa L.)

    Get PDF
    Hemp (Cannabis sativa L.) contains a wide range of biocompounds with different beneficial properties such as anti-inflammatory, antithrombotic, antiarrhythmic, hypolipidemic and antioxidative. Response Surface Methodology (RSM) coupled with Box-Behnken design (BBD) was applied to determine the influence of extraction temperature, liquid to solid ratio, extraction time, rotational speed and ethanol/water solvent ratios at three levels on the solid-liquid extraction of the bioactives from the hemp (flowers, leaves, seeds, stems). Based on the obtained results, liquid to solid ratio, temperature and ethanol/water solvent ratio had statistically significant effects on the total polyphenolic content (TPC), while extraction time and rotational speed had no influence on the TPC extraction. Regarding antioxidant activity (AOX) determined by the DPPH method, only liquid to solid ratio had a statistically significant effect. Liquid to solid ratio, ethanol/water solvent ratio, temperature and rotational speed significantly influenced AOX determined by the FRAP method. According to BBD, the optimum extraction conditions were as follows: extraction temperature 45 °C, liquid to solid ratio 30 mL/g, extraction time 25 min, rotational speed 500 rpm, ethanol/water solvent ratio 25%. RSM coupled with a BBD model was shown to be effective for optimization the solid-liquid extraction of hemp

    NEAR INFRARED SPECTROSCOPY (NIRS) COUPLED WITH CHEMOMETRIC TOOLS USED FOR FOOD PRODUCTS ADULTERATION DETECTION

    Get PDF
    The growing problem of food products adulteration requires a rapid and simple method for adulteration detection. Adulterants, which can range from plant material to natural and synthetic colours and compounds have a severe influence on customer trust as well as public health risks. Food safety regulations are being tightened and expanded, requiring a more thorough examination of hazards and risk management solutions. Due to its advantages, near infrared spectroscopy has been recognised as an effective method for food adulteration detection. In this work, an overview of the basics of NIR spectroscopy, NIR data analysis and the use of NIR for food adulteration detection are discussed

    NEAR INFRARED SPECTROSCOPY (NIRS) COUPLED WITH CHEMOMETRIC TOOLS USED FOR FOOD PRODUCTS ADULTERATION DETECTION

    Get PDF
    The growing problem of food products adulteration requires a rapid and simple method for adulteration detection. Adulterants, which can range from plant material to natural and synthetic colours and compounds have a severe influence on customer trust as well as public health risks. Food safety regulations are being tightened and expanded, requiring a more thorough examination of hazards and risk management solutions. Due to its advantages, near infrared spectroscopy has been recognised as an effective method for food adulteration detection. In this work, an overview of the basics of NIR spectroscopy, NIR data analysis and the use of NIR for food adulteration detection are discussed

    Emulgiranje na mikrorazini: brže, bolje i učinkovitije

    Get PDF
    Emulsions are traditionally prepared with the application of high shear forces generated by the use of static mixers, homogenisers, or ultrasound. The resulting emulsions are sensitive to change of process conditions. The application of high forces and temperatures can significantly affect the constituents of the emulsions and their final stability. Microfluidic technology seems to be a very efficient alternative to classic emulsification methods. The dimensions of microdevices in combination with continuous processes offer a great advantage over classic batch emulsification processes carried out on a larger scale. The small dimensions of the microdevices allow easy transport of equipment, better control and safety of the process, and intensified mass and energy transfer. The mixing time in microdevices is reduced to a few milliseconds because the molecules in the microchannels have a short diffusion path. In this paper, an overview of emulsification processes, the advantages of use of microfluidics in emulsification, and future perspectives of microemulsification are presented.Tradicionalno se emulzije pripremaju primjenom jakih smičnih sila koje nastaju upotrebom statičkih miješala, homogenizatora ili primjenom ultrazvuka. Tako proizvedene emulzije osjetljive su na promjenu procesnih uvjeta. Primjena jakih sila i povišenih temperatura može značajno utjecati na komponente emulzija i njihovu konačnu stabilnost. Primjena protočnih mikrosustava pokazala se učinkovitom alternativnom tehnologijom klasičnim metodama emulgiranja. Male dimenzije mikrouređaja u kombinaciji s kontinuiranom provedbom procesa omogućuje brojne prednosti u odnosu na klasične šaržne procese emulsifikacije koji se provode u većem mjerilu. Male dimenzije mikrouređaja omogućuju lakši transport opreme, bolju kontrolu i sigurnost procesa te intenzivniji prijenos tvari i topline. Vrijeme miješanja u mikrouređajima smanjeno je na nekoliko milisekundi zbog kratkog difuzijskog puta molekula u mikrokanalima. U ovom radu dan je pregled procesa emulgiranja, prednosti primjene protočnih mikrosustava u provedbi procesa emulgiranja te potencijalnih novih područja primjene te tehnologije

    Influence of Sample Matrix on Determination of Histamine in Fish by Surface Enhanced Raman Spectroscopy Coupled with Chemometric Modelling

    Get PDF
    Histamine fish poisoning is a foodborne illness caused by the consumption of fish products with high histamine content. Although intoxication mechanisms and control strategies are well known, it remains by far the most common cause of seafood-related health problems. Since conventional methods for histamine testing are difficult to implement in high-throughput quality control laboratories, simple and rapid methods for histamine testing are needed to ensure the safety of seafood products in global trade. In this work, the previously developed SERS method for the determination of histamine was tested to determine the influence of matrix effect on the performance of the method and to investigate the ability of different chemometric tools to overcome matrix effect issues. Experiments were performed on bluefin tuna (Thunnus thynnus) and bonito (Sarda sarda) samples exposed to varying levels of microbial activity. Spectral analysis confirmed the significant effect of sample matrix, related to different fish species, as well as the extent of microbial activity on the predictive ability of PLSR models with R2 of best model ranging from 0.722–0.945. Models obtained by ANN processing of factors derived by PCA from the raw spectra of the samples showed excellent prediction of histamine, regardless of fish species and extent of microbial activity (R2 of validation > 0.99)
    corecore