404 research outputs found

    Echocardiographic evaluation of left ventricular outflow tract obstruction in complete transposition of the great arteries

    Get PDF
    Subpulmonic stenosis in complete d-transposition of the great arteries (d-TGA) is a frequently associated malformation, the precise diagnosis of which is essential for optimal medical and surgical treatment. Sixteen patients with d-TGA and subpulmonic stenosis have been studied by M-mode and two-dimensional (2DE) echocardiography and cardiac catheterization. Dynamic obstruction was found in six patients and fixed stenosis in 10. Systolic anterior motion of the mitral valve without fixed obstruction of the left ventricular outflow tract (LVOT) was present in patients with dynamic stenosis. Measurements of left ventricular end-diastolic posterior wall thickness to minor semiaxis ratio correlated well (p < 0.001) with the pressure gradient across the LVOT. Various types of anatomic fixed obstruction are described. M-mode echocardiography provides assessment of dynamic obstruction but does not allow quantitative evaluation of the length of the narrowed segment. The latter can be achieved by 2DE, which offers improved definition of different anatomic types

    Usefulness of transesophageal echocardiography in the assessment of aortic dissection

    Get PDF
    The acute dissection of the ascending aorta requires prompt and reliable diagnosis to reduce the high risk of mortality; in addition, prognosis is influenced by longterm complications. The aim of this article is to discuss transesophageal echocardiography (TEE) and (1) its diagnostic accuracy in the presurgical evaluation of patients, (2) its role in reducing time of diagnosis and surgery, and (3) its ability to reduce hospital mortality. TEE has also been tested as a screening method in the postsurgical follow-up of these patients. The retrospective investigation concerns a sample of 80 cases of acute dissection of the aorta, submitted for surgical intervention from April 1986 to February 1999. TEE has allowed a precise estimation of aortic diameters and optimal visualization of intimal flap and tear entry with a fine distinction between true and false lumen. A direct comparison of the results of TEE and of transthoracic echocardiography has demonstrated that some elements (visualization of flap and diameters in descending aorta, sites of entry and reentry, direction of let trough intimal tears, phasic intimal flap movement, diastolic collapse of flap on the valvular plane, false lumen thrombosis, coronary involvement, intramural hematoma, and aortic fissuration) were identified only by TEE, whereas other additional diagnostic elements (cardiac tamponade, aortic valve insufficiency, left ventricular function) show a similar pattern of significance. Routine employment of this method has confirmed a reduction of hospitalization time (about 1.5 hours of waiting time), and hospital mortality has changed from 42.8% to 17.3%. In the follow-up of patients operated on for aortic dissection, fundamental information may be obtained from TEE (assessment of the progression of thrombosis in the false lumen with its complete obliteration and modifications in aortic diameter with a consequent, possible worsening of aortic valve insufficiency). In conclusion, our study demonstrated that TEE may provide fast and efficient detection of acute aortic dissection. In the postsurgical follow-up, TEE has confirmed detection of major complications that can influence long-term prognosis and may be proposed as a method with easy access-one that is repeatable and inexpensive for the screening of aortic dissection surgical patients. (C) 2000 by Excerpta Medica, Inc

    Identification of viable myocardium in patients with chronic coronary artery disease and left ventricular dysfunction: role of MRI.

    Get PDF
    Nineteen patients (16 men and 3 women, mean age 51 years) with previous anterior myocardial infarction and severe stenosis (&gt; or = 90%) of the left anterior descending coronary artery were studied by magnetic resonance imaging (MRI) without and with contrast media to verify the capability of MRI in identifying viable myocardium in areas of severe systolic dysfunction. In corresponding left ventricular segments, a comparison was made between regional signal intensities (SI) determined on MRI images before and 4, 8, 12, and 30 minutes after administration of paramagnetic contrast media (gadolinium diethylenetriaminepentaacetic acid, 0.4 mmol/kg intravenously) and metabolic parameters determined by iodine 123 phenylpentadecanoic acid (IPPA) scintigraphy. The SI and the time of maximum postcontrast enhancement were analyzed by dividing the left ventricle into 11 segments. Each segment was classified as normal (group 1, n = 116), hibernating (group 2, n = 50), or necrotic (group 3, n = 43) on the basis of the IPPA washout rate (&gt; 30%, 10% to 30%, and &lt; 10%, respectively). Regional SI demonstrated significant differences in absolute values at 12 minutes (group 3: 1.62 +/- 0.58 vs group 1: 1.32 +/- 0.52, p &lt; 0.01, and vs group 2: 1.34 +/- 0.48, p &lt; 0.05) and at 30 minutes (group 3: 1.71 +/- 0.47 vs group 1: 1.21 +/- 0.55, p &lt; 0.01, and vs group 2: 1.49 +/- 0.57, p &lt; 0.05) and in temporal distribution. These results suggest that MRI has a potential role in differentiating viable from necrotic myocardium in patients with chronic severe systolic dysfunction

    Identification and quantification of prosthetic mitral regurgitation by flow convergence method using transthoracic approach

    Get PDF
    The present case report illustrates the clinical applicability of the proximal isovelocity surface area (PISA) method in identifying, locating and assessing paravalvular prosthetic mitral regurgitation by transthoracic echocardiography

    Coronary artery to left ventricle fistula

    Get PDF
    BACKGROUND: Coronary cameral fistulas are an uncommon entity, the etiology of which may be congenital or traumatic. They involve abnormal termination of a coronary artery, usually the right coronary, into a cardiac chamber, usually the right ventricle. CASE PRESENTATION: We describe a case of female patient with severe aortic stenosis and interventricular septal hypertrophy that underwent bioprosthetic aortic valve replacement with concomitant septal myectomy. On subsequent follow-up an abnormal flow traversing the septum into the left ventricle was identified and Doppler interrogation demonstrated a continuous flow, with a predominantly diastolic component, consistent with coronary arterial flow. CONCLUSION: The literature on coronary cameral fistulas is reviewed and the etiology of the diagnostic findings discussed. In our patient, a coronary artery to left ventricle fistula was the most likely explanation secondary to trauma to the septal perforator artery during myectomy. Since the patient was asymptomatic at the time of diagnosis no intervention was recommended and has done well on follow-up

    Clinical and echocardiographic predictors of mortality in acute pulmonary embolism

    Get PDF
    Purpose: The aim of this study was to evaluate the utility of adding quantitative assessments of cardiac function from echocardiography to clinical factors in predicting the outcome of patients with acute pulmonary embolism (PE). Methods: Patients with a diagnosis of acute PE, based on a positive ventilation perfusion scan or computed tomography (CT) chest angiogram, were identified using the Duke University Hospital Database. Of these, 69 had echocardiograms within 24–48 h of the diagnosis that were suitable for offline analysis. Clinical features that were analyzed included age, gender, body mass index, vital signs and comorbidities. Echocardiographic parameters that were analyzed included left ventricular (LV) ejection fraction (EF), regional, free wall and global RV speckle-tracking strain, RV fraction area change (RVFAC), Tricuspid Annular Plane Systolic Excursion (TAPSE), pulmonary artery acceleration time (PAAT) and RV myocardial performance (Tei) index. Univariable and multivariable regression statistical analysis models were used. Results: Out of 69 patients with acute PE, the median age was 55 and 48 % were female. The median body mass 2 index (BMI) was 27 kg/m . Twenty-nine percent of the cohort had a history of cancer, with a significant increase in cancer prevalence in non-survivors (57 % vs 29 %, p = 0.02). Clinical parameters including heart rate, respiratory rate, troponin T level, active malignancy, hypertension and COPD were higher among non-survivors when compared to survivors (p ≤ 0.05). Using univariable analysis, NYHA class III symptoms, hypoxemia on presentation, tachycardia, tachypnea, elevation in Troponin T, absence of hypertension, active malignancy and chronic obstructive pulmonary disease (COPD) were increased in non-survivors compared to survivors (p ≤ 0.05). In multivariable models, RV Tei Index, global and free (lateral) wall RVLS were found to be negatively associated with survival probability after adjusting for age, gender and systolic blood pressure (p ≤ 0.05). Conclusion: The addition of echocardiographic assessment of RV function to clinical parameters improved the prediction of outcomes for patients with acute PE. Larger studies are needed to validate these findings

    Aortic root dimension changes during systole and diastole: evaluation with ECG-gated multidetector row computed tomography

    Get PDF
    Cardiac pulsatility and aortic compliance may result in aortic area and diameter changes throughout the cardiac cycle in the entire aorta. Until this moment these dynamic changes could never be established in the aortic root (aortic annulus, sinuses of Valsalva and sinotubular junction). The aim of this study was to visualize and characterize the changes in aortic root dimensions during systole and diastole with ECG-gated multidetector row computed tomography (MDCT). MDCT scans of subjects without aortic root disease were analyzed. Retrospectively, ECG-gated reconstructions at each 10% of the cardiac cycle were made and analyzed during systole (30–40%) and diastole (70–75%). Axial planes were reconstructed at three different levels of the aortic root. At each level the maximal and its perpendicular luminal dimension were measured. The mean dimensions of the total study group (n = 108, mean age 56 ± 13 years) do not show any significant difference between systole and diastole. The individual dimensions vary up to 5 mm. However, the differences range between minus 5 mm (diastolic dimension is greater than systolic dimensions) and 5 mm (vice versa). This variability is independent of gender, age, height and weight. This study demonstrated a significant individual dynamic change in the dimensions of the aortic root. These results are highly unpredictable. Most of the healthy subjects have larger systolic dimensions, however, some do have larger diastolic dimensions
    corecore