24 research outputs found

    Pheochromocytoma presenting with arterial and intracardiac thrombus in a 47-year-old woman: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Pheochromocytoma is a rare cause of hypertension but it could have severe consequences if not recognized and treated appropriately. The association of pheochromocytoma and thrombosis is even rarer but significantly increases management complexity, morbidity and mortality. To the best of our knowledge, this is the first report of a patient with pheochromocytoma presenting with left axillary arterial and intracardiac thrombus.</p> <p>Case presentation</p> <p>A 47-year-old Caucasian woman with a past medical history of hypertension presented for medical attention with left arm numbness. Doppler ultrasound showed an obstructing thrombus in her left axillary artery. She had symptom resolution after stent placement in her left axillary artery. A subsequent echocardiogram demonstrated a large intracardiac mass and abdominal computed tomography revealed a 7 cm mass between her spleen and left kidney. Labile blood pressure was noted during admission and she had very high levels of plasma and 24-hour urine catecholamines and metanephrines tests. A (123)I- metaiodobenzylguanidine scan showed intense uptake in the left abdominal mass. After adequate alpha blockage with phenoxybenzamine, laparoscopic tumor resection was performed without complications. She had normal metanephrines and complete symptom resolution afterwards. The intracardiac mass also disappeared with anticoagulation. All other endocrine laboratory abnormalities returned to normal after surgery.</p> <p>Conclusion</p> <p>Arterial and ventricular thrombosis occurring in patients with pheochromocytoma is rare. A multi-disciplinary approach is necessary in caring for this type of patient. Catecholamines likely contributed to the development of thrombosis in our patient. Early recognition of pheochromocytoma is the key to improving outcome.</p

    Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography

    Get PDF
    BACKGROUND: The prosthesis used for aortic valve replacement in patients with small aortic root can be too small in relation to body size, thus showing high transvalvular gradients at rest and/or under stress conditions. This study was carried out to evaluate rest and Dobutamine stress echocardiography (DSE) hemodynamic response of 17-mm St. Jude Medical Regent (SJMR-17 mm) in relatively aged patients at mean 24 months follow-up. METHODS AND RESULTS: The study population consisted of 19 patients (2 men, 17 women, mean age 69.2 Ā± 7.3 years). All patients underwent rest Doppler echocardiography before and after surgery and basal and DSE at follow up (infused at rate of 5 micrg/Kg/min and increased by 5 microg/Kg/min at 5 min intervals up to 40 microg/Kg/min). The following parameters were evaluated at rest and/or under DSE: heart rate (HR), ejection fraction (EF), cardiac output (CO), peak and mean velocity and pressure gradients (MxV, MnV, MxPG, MnPG), effective orifice area (EOA), indexed EOA (EOAi), left ventricular mass (LVM), indexed LVM (LVMi), Velocity Time Integral at left ventricular outflow tract (VTI LVOT) and transvalvular (Aortic VTI), Doppler velocity index (DVI). At rest MxPG and MnPG were 29.2 Ā± 7.1 and 16.6 Ā± 5.8mmHg, respectively; EOA and EOAi resulted 1.14 Ā± 0.3 cm(2) and 0.76 Ā± 0.2 cm(2)/m(2); DVI was normal (0.50 Ā± 0.1). At follow-up LVM and LVMi decreased significantly from pre-operative value of 258 Ā± 43g and 157.4 Ā± 27.7g/m(2) to 191 Ā± 23.8g and 114.5 Ā± 10.6g/m(2), respectively. DSE increased significantly HR, CO, EF, MxGP (up to 83.4 Ā± 2 1.9mmHg), MnPG (up to 43.2 Ā± 12.7mmHg). EOA, EOAi, DVI increased insignificantly (from baseline up to 1.2 Ā± 0.4 cm(2), 0.75 Ā± 0.3cm(2)/m(2) and 0.48 Ā± 0.1 respectively). Two patients developed significant intraventricular gradients. CONCLUSION: These data show that SJMR 17-mm prostheses can be safely implanted in aortic position in relatively aged patients, offering a satisfactory hemodynamic performance at rest and under DSE, with full utilization of its available orifice, suggesting that a possible mild prosthesis-patient mismatch is not an issue of clinical relevance when this small prosthesis is used. Rest and Dobutamine stress echocardiography is a useful and effective means for evaluating prosthesis hemodynamics and for monitoring the expected LVH regression

    Evolution of Mitral Valve Prolapse

    No full text
    corecore