125 research outputs found

    A Performance Analysis Framework for WiFi/WiMAX Heterogeneous Metropolitan Networks Based on Cross-Layer Design

    Get PDF
    The communication between network nodes within different protocol domains is often regarded simply as a black box with unknown configuration conditions in the path. We address network heterogeneity using a white box approach and focus on its interconnection processes. To achieve this purpose, a Performance Analysis Framework (PAF) is proposed which is composed of the formalization of the latter using process algebra (PA) and the corresponding teletraffic performance models. In this contribution, we target the IEEE 802.16 and IEEE 802.11 protocols. For the teletraffic models, we extend previous models for such scenario with the inclusion of the following protocol operational parameters (metrics): bit error rate (BER), packet error ratio (PER), and packet length (pl). From the framework teletraffic models, the optimal packet length (OPL), end to end throughput, delay, and packet loss are obtained. The PAF outperforms previous modeling solutions in terms of delay and throughput relative to NS3 simulation results. </jats:p

    Colliders and Cosmology

    Full text link
    Dark matter in variations of constrained minimal supersymmetric standard models will be discussed. Particular attention will be given to the comparison between accelerator and direct detection constraints.Comment: Submitted for the SUSY07 proceedings, 15 pages, LaTex, 26 eps figure

    The exposure of the hybrid detector of the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Observatory is a detector for ultra-high energy cosmic rays. It consists of a surface array to measure secondary particles at ground level and a fluorescence detector to measure the development of air showers in the atmosphere above the array. The "hybrid" detection mode combines the information from the two subsystems. We describe the determination of the hybrid exposure for events observed by the fluorescence telescopes in coincidence with at least one water-Cherenkov detector of the surface array. A detailed knowledge of the time dependence of the detection operations is crucial for an accurate evaluation of the exposure. We discuss the relevance of monitoring data collected during operations, such as the status of the fluorescence detector, background light and atmospheric conditions, that are used in both simulation and reconstruction.Comment: Paper accepted by Astroparticle Physic

    Atmospheric effects on extensive air showers observed with the Surface Detector of the Pierre Auger Observatory

    Get PDF
    Atmospheric parameters, such as pressure (P), temperature (T) and density, affect the development of extensive air showers initiated by energetic cosmic rays. We have studied the impact of atmospheric variations on extensive air showers by means of the surface detector of the Pierre Auger Observatory. The rate of events shows a ~10% seasonal modulation and ~2% diurnal one. We find that the observed behaviour is explained by a model including the effects associated with the variations of pressure and density. The former affects the longitudinal development of air showers while the latter influences the Moliere radius and hence the lateral distribution of the shower particles. The model is validated with full simulations of extensive air showers using atmospheric profiles measured at the site of the Pierre Auger Observatory.Comment: 24 pages, 9 figures, accepted for publication in Astroparticle Physic

    Update on the correlation of the highest energy cosmic rays with nearby extragalactic matter

    Get PDF
    Data collected by the Pierre Auger Observatory through 31 August 2007 showed evidence for anisotropy in the arrival directions of cosmic rays above the Greisen-Zatsepin-Kuz'min energy threshold, \nobreak{6×10196\times 10^{19}eV}. The anisotropy was measured by the fraction of arrival directions that are less than 3.1∘3.1^\circ from the position of an active galactic nucleus within 75 Mpc (using the V\'eron-Cetty and V\'eron 12th12^{\rm th} catalog). An updated measurement of this fraction is reported here using the arrival directions of cosmic rays recorded above the same energy threshold through 31 December 2009. The number of arrival directions has increased from 27 to 69, allowing a more precise measurement. The correlating fraction is (38−6+7)(38^{+7}_{-6})%, compared with 2121% expected for isotropic cosmic rays. This is down from the early estimate of (69−13+11)(69^{+11}_{-13})%. The enlarged set of arrival directions is examined also in relation to other populations of nearby extragalactic objects: galaxies in the 2 Microns All Sky Survey and active galactic nuclei detected in hard X-rays by the Swift Burst Alert Telescope. A celestial region around the position of the radiogalaxy Cen A has the largest excess of arrival directions relative to isotropic expectations. The 2-point autocorrelation function is shown for the enlarged set of arrival directions and compared to the isotropic expectation.Comment: Accepted for publication in Astroparticle Physics on 31 August 201

    The Fluorescence Detector of the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions.Comment: 53 pages. Submitted to Nuclear Instruments and Methods in Physics Research Section

    Advanced functionality for radio analysis in the Offline software framework of the Pierre Auger Observatory

    Get PDF
    The advent of the Auger Engineering Radio Array (AERA) necessitates the development of a powerful framework for the analysis of radio measurements of cosmic ray air showers. As AERA performs "radio-hybrid" measurements of air shower radio emission in coincidence with the surface particle detectors and fluorescence telescopes of the Pierre Auger Observatory, the radio analysis functionality had to be incorporated in the existing hybrid analysis solutions for fluoresence and surface detector data. This goal has been achieved in a natural way by extending the existing Auger Offline software framework with radio functionality. In this article, we lay out the design, highlights and features of the radio extension implemented in the Auger Offline framework. Its functionality has achieved a high degree of sophistication and offers advanced features such as vectorial reconstruction of the electric field, advanced signal processing algorithms, a transparent and efficient handling of FFTs, a very detailed simulation of detector effects, and the read-in of multiple data formats including data from various radio simulation codes. The source code of this radio functionality can be made available to interested parties on request.Comment: accepted for publication in NIM A, 13 pages, minor corrections to author list and references in v

    Search for First Harmonic Modulation in the Right Ascension Distribution of Cosmic Rays Detected at the Pierre Auger Observatory

    Get PDF
    We present the results of searches for dipolar-type anisotropies in different energy ranges above 2.5×10172.5\times 10^{17} eV with the surface detector array of the Pierre Auger Observatory, reporting on both the phase and the amplitude measurements of the first harmonic modulation in the right-ascension distribution. Upper limits on the amplitudes are obtained, which provide the most stringent bounds at present, being below 2% at 99% C.L.C.L. for EeV energies. We also compare our results to those of previous experiments as well as with some theoretical expectations.Comment: 28 pages, 11 figure

    Clinical phenotypes of acute heart failure based on signs and symptoms of perfusion and congestion at emergency department presentation and their relationship with patient management and outcomes

    Get PDF
    Objective To compare the clinical characteristics and outcomes of patients with acute heart failure (AHF) according to clinical profiles based on congestion and perfusion determined in the emergency department (ED). Methods and results Overall, 11 261 unselected AHF patients from 41 Spanish EDs were classified according to perfusion (normoperfusion = warm; hypoperfusion = cold) and congestion (not = dry; yes = wet). Baseline and decompensation characteristics were recorded as were the main wards to which patients were admitted. The primary outcome was 1-year all-cause mortality; secondary outcomes were need for hospitalisation during the index AHF event, in-hospital all-cause mortality, prolonged hospitalisation, 7-day post-discharge ED revisit for AHF and 30-day post-discharge rehospitalisation for AHF. A total of 8558 patients (76.0%) were warm+ wet, 1929 (17.1%) cold+ wet, 675 (6.0%) warm+ dry, and 99 (0.9%) cold+ dry; hypoperfused (cold) patients were more frequently admitted to intensive care units and geriatrics departments, and warm+ wet patients were discharged home without admission. The four phenotypes differed in most of the baseline and decompensation characteristics. The 1-year mortality was 30.8%, and compared to warm+ dry, the adjusted hazard ratios were significantly increased for cold+ wet (1.660; 95% confidence interval 1.400-1.968) and cold+ dry (1.672; 95% confidence interval 1.189-2.351). Hypoperfused (cold) phenotypes also showed higher rates of index episode hospitalisation and in-hospital mortality, while congestive (wet) phenotypes had a higher risk of prolonged hospitalisation but decreased risk of rehospitalisation. No differences were observed among phenotypes in ED revisit risk. Conclusions Bedside clinical evaluation of congestion and perfusion of AHF patients upon ED arrival and classification according to phenotypic profiles proposed by the latest European Society of Cardiology guidelines provide useful complementary information and help to rapidly predict patient outcomes shortly after ED patient arrival
    • 

    corecore