45 research outputs found

    Experimental Evidence of Direct Exchange Interaction Mediating Intramolecular Singlet Fission in Weakly-Coupled Dimers

    Full text link
    The electronic interaction between an optically active singlet state (S1S0S_1S_0) and a dark state of singlet multiplicity, known as correlated triplet pair (1[TT]^1[TT]), plays a crucial role in the effective transformation from S1S0S_1S_0 to 1[TT]^1[TT] during intramolecular singlet fission (iSF). This process is understood through mechanisms such as direct exchange coupling and incoherent processes that involve super-exchange coupling through charge-transfer states. However, most insights into these mechanisms are derived from theoretical studies due to the difficulties in obtaining experimental evidence. In this study, we investigate the excited-state interactions between S1S0S_1S_0 and 1[TT]^1[TT] in spiro-conjugated iSF sensitizers by employing transient two-dimensional electronic spectroscopy. This approach allows us to focus on the early stages of the conversion from S1S0S_1S_0 to 1[TT]^1[TT]. Upon optical excitation, a superposition of S1S0S_1S_0 and 1[TT]^1[TT] is created, which gradually transitions to favor 1[TT]^1[TT] within the characteristic time frames of iSF. The observed high-order signals indicate circular repopulation dynamic that effectively reinitiates the iSF process from higher energy electronic states. Our findings, supported by semi-quantum-mechanical simulations of the experimental data, suggest the presence of a direct iSF mechanism in the dimers, facilitated by weak non-adiabatic coupling between S1S0S_1S_0 and 1[TT]^1[TT]. This experiment provides new insights into the equilibrium between the two electronic states, a phenomenon previously understood primarily through theoretical models.Comment: 26 pages, 4 Figure

    Multidetector computed tomography angiography for assessment of in-stent restenosis: meta-analysis of diagnostic performance

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Multi-detector computed tomography angiography (MDCTA)of the coronary arteries after stenting has been evaluated in multiple studies.</p> <p>The purpose of this study was to perform a structured review and meta-analysis of the diagnostic performance of MDCTA for the detection of in-stent restenosis in the coronary arteries.</p> <p>Methods</p> <p>A Pubmed and manual search of the literature on in-stent restenosis (ISR) detected on MDCTA compared with conventional coronary angiography (CA) was performed. Bivariate summary receiver operating curve (SROC) analysis, with calculation of summary estimates was done on a stent and patient basis. In addition, the influence of study characteristics on diagnostic performance and number of non-assessable segments (NAP) was investigated with logistic meta-regression.</p> <p>Results</p> <p>Fourteen studies were included. On a stent basis, Pooled sensitivity and specificity were 0.82(0.72–0.89) and 0.91 (0.83–0.96). Pooled negative likelihood ratio and positive likelihood ratio were 0.20 (0.13–0.32) and 9.34 (4.68–18.62) respectively. The exclusion of non-assessable stents and the strut thickness of the stents had an influence on the diagnostic performance. The proportion of non-assessable stents was influenced by the number of detectors, stent diameter, strut thickness and the use of an edge-enhancing kernel.</p> <p>Conclusion</p> <p>The sensitivity of MDTCA for the detection of in-stent stenosis is insufficient to use this test to select patients for further invasive testing as with this strategy around 20% of the patients with in-stent stenosis would be missed. Further improvement of scanner technology is needed before it can be recommended as a triage instrument in practice. In addition, the number of non-assessable stents is also high.</p

    Percutaneous treatment of patients with heart diseases: selection, guidance and follow-up. A review

    Get PDF
    Aortic stenosis and mitral regurgitation, patent foramen ovale, interatrial septal defect, atrial fibrillation and perivalvular leak, are now amenable to percutaneous treatment. These percutaneous procedures require the use of Transthoracic (TTE), Transesophageal (TEE) and/or Intracardiac echocardiography (ICE). This paper provides an overview of the different percutaneous interventions, trying to provide a systematic and comprehensive approach for selection, guidance and follow-up of patients undergoing these procedures, illustrating the key role of 2D echocardiography

    A meta-analysis of N-acetylcysteine in contrast-induced nephrotoxicity: unsupervised clustering to resolve heterogeneity

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Meta-analyses of N-acetylcysteine (NAC) for preventing contrast-induced nephrotoxicity (CIN) have led to disparate conclusions. Here we examine and attempt to resolve the heterogeneity evident among these trials.</p> <p>Methods</p> <p>Two reviewers independently extracted and graded the data. Limiting studies to randomized, controlled trials with adequate outcome data yielded 22 reports with 2746 patients.</p> <p>Results</p> <p>Significant heterogeneity was detected among these trials (<it>I</it><sup>2 </sup>= 37%; <it>p </it>= 0.04). Meta-regression analysis failed to identify significant sources of heterogeneity. A modified L'Abbé plot that substituted groupwise changes in serum creatinine for nephrotoxicity rates, followed by model-based, unsupervised clustering resolved trials into two distinct, significantly different (<it>p </it>< 0.0001) and homogeneous populations (<it>I</it><sup>2 </sup>= 0 and <it>p </it>> 0.5, for both). Cluster 1 studies (<it>n </it>= 18; 2445 patients) showed no benefit (relative risk (RR) = 0.87; 95% confidence interval (CI) 0.68–1.12, <it>p </it>= 0.28), while cluster 2 studies (<it>n </it>= 4; 301 patients) indicated that NAC was highly beneficial (RR = 0.15; 95% CI 0.07–0.33, <it>p </it>< 0.0001). Benefit in cluster 2 was unexpectedly associated with NAC-induced decreases in creatinine from baseline (<it>p </it>= 0.07). Cluster 2 studies were relatively early, small and of lower quality compared with cluster 1 studies (<it>p </it>= 0.01 for the three factors combined). Dialysis use across all studies (five control, eight treatment; <it>p </it>= 0.42) did not suggest that NAC is beneficial.</p> <p>Conclusion</p> <p>This meta-analysis does not support the efficacy of NAC to prevent CIN.</p

    Potential biological role of poly (ADP-ribose) polymerase (PARP) in male gametes

    Get PDF
    Maintaining the integrity of sperm DNA is vital to reproduction and male fertility. Sperm contain a number of molecules and pathways for the repair of base excision, base mismatches and DNA strand breaks. The presence of Poly (ADP-ribose) polymerase (PARP), a DNA repair enzyme, and its homologues has recently been shown in male germ cells, specifically during stage VII of spermatogenesis. High PARP expression has been reported in mature spermatozoa and in proven fertile men. Whenever there are strand breaks in sperm DNA due to oxidative stress, chromatin remodeling or cell death, PARP is activated. However, the cleavage of PARP by caspase-3 inactivates it and inhibits PARP's DNA-repairing abilities. Therefore, cleaved PARP (cPARP) may be considered a marker of apoptosis. The presence of higher levels of cPARP in sperm of infertile men adds a new proof for the correlation between apoptosis and male infertility. This review describes the possible biological significance of PARP in mammalian cells with the focus on male reproduction. The review elaborates on the role played by PARP during spermatogenesis, sperm maturation in ejaculated spermatozoa and the potential role of PARP as new marker of sperm damage. PARP could provide new strategies to preserve fertility in cancer patients subjected to genotoxic stresses and may be a key to better male reproductive health

    Procedural, 30-day and one year outcome following CoreValve or Edwards transcatheter aortic valve implantation: results of the Belgian national registry.

    Full text link
    We report clinical outcomes following transcatheter aortic valve implantation (TAVI), using the CoreValve revalving system (18 Fr transfemoral or subclavian) or the Edwards Sapien valve (22 Fr transfemoral or 24 Fr transapical) as part of a Belgian prospective non-randomized multicentre registry. All 15 Belgian centres performing TAVI participated to this registry (seven exclusively Edwards Sapien, eight exclusively CoreValve). All consecutive high-risk symptomatic patients with severe aortic stenosis were evaluated by a heart team and screened for eligibility for TAVI. Three hundred and twenty-eight patients underwent TAVI with CoreValve (n = 141; eight subclavian and 133 transfemoral) or Edwards Sapien (n = 187; 99 transfemoral and 88 transapical) up to April 2010. Procedural success was 97%. One-month survival was 88% for the Edwards and 89% for the CoreValve treated patients. One-month mortality was both related to cardiac and non-cardiac reasons. Overall one-year survival was 78% in the CoreValve transfemoral treated patients, 100% in the CoreValve subclavian treated patients, 82% in the Edwards transfemoral treated patients and 63% in the Edwards transapical treated patients. This mid-term mortality was mainly related to age-related, non-cardiac complications

    Waermeuebergang und Druckverlust in einseitig beheizten, geneigten und innenberippten Rohren Schlussbericht

    No full text
    SIGLETIB Hannover: RO 7152(24) / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekDEGerman

    Plastics in our ocean as transdisciplinary challenge

    No full text
    This conference report summarizes the current challenges of researching microplastics pollution in the ocean as debated by international experts and stakeholders at a workshop held in San Sebastián, Spain, 1–2 October 2019. The transdisciplinary, co-learning approach of this report stressed the need to incorporate multiple perspective in solving the problem of microplastics and resulted in three proposed actions: (i) filtering microplastics from waste waters; (ii) mandatory ecolabels on plastic products packages; and (iii) circular economy of packaging plastics
    corecore