38 research outputs found

    Attitudes of Ghanaian women toward genetic testing for sickle cell trait

    Full text link
    ObjectiveTo explore the attitudes of Ghanaian women toward genetic testing for the sickle cell trait and to investigate key factors that promote or impede the decision to pursue knowledge of the carrier status.MethodsA survey, administered in person to Ghanaian women, collected demographic information and information on the participants’ knowledge about their carrier status, their attitudes toward genetic testing, and their perceptions of the implications of being a carrier. The results for women who had previously undergone testing and those who had not were compared.ResultsOf 124 participants, 75 had been tested for the sickle cell trait and 49 had not. Some 53% of the women who had been tested did not know their carrier status. Most women agreed that getting a prenatal genetic test was important. However, nontested women were more likely to lack the financial resources to undergo testing, to think that testing is futile because sickle cell disease is not curable, and to believe that the outcome of their child’s health is determined by God.ConclusionThe women tended to have favorable attitudes toward genetic testing, but numerous barriers remained that precluded knowledge of their carrier status or the pursuit of this knowledge.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/135529/1/ijgo264.pd

    TIN-X:target importance and novelty explorer

    Get PDF
    Abstract Motivation The increasing amount of peer-reviewed manuscripts requires the development of specific mining tools to facilitate the visual exploration of evidence linking diseases and proteins. Results We developed TIN-X, the Target Importance and Novelty eXplorer, to visualize the association between proteins and diseases, based on text mining data processed from scientific literature. In the current implementation, TIN-X supports exploration of data for G-protein coupled receptors, kinases, ion channels, and nuclear receptors. TIN-X supports browsing and navigating across proteins and diseases based on ontology classes, and displays a scatter plot with two proposed new bibliometric statistics: Importance and Novelty. Availability and Implementation http://www.newdrugtargets.org </jats:sec

    Dermal Sensory Regenerative Peripheral Nerve Interface for Reestablishing Sensory Nerve Feedback in Peripheral Afferents in the Rat

    Get PDF
    Background: Without meaningful, intuitive sensory feedback, even the most advanced myoelectric devices require significant cognitive demand to control. The dermal sensory regenerative peripheral nerve interface (DS-RPNI) is a biological interface designed to establish high-fidelity sensory feedback from prosthetic limbs. Methods: DS-RPNIs were constructed in rats by securing fascicles of residual sensory peripheral nerves into autologous dermal grafts, with the objectives of confirming regeneration of sensory afferents within DS-RPNIs and establishing the reliability of afferent neural response generation with either mechanical or electrical stimulation. Results: Two months after implantation, DS-RPNIs were healthy and displayed well-vascularized dermis with organized axonal collaterals throughout and no evidence of neuroma. Electrophysiologic signals were recorded proximal from DS-RPNI's sural nerve in response to both mechanical and electrical stimuli and compared with (1) full-thickness skin, (2) deepithelialized skin, and (3) transected sural nerves without DS-RPNI. Mechanical indentation of DS-RPNIs evoked compound sensory nerve action potentials (CSNAPs) that were like those evoked during indentation of full-thickness skin. CSNAP firing rates and waveform amplitudes increased in a graded fashion with increased mechanical indentation. Electrical stimuli delivered to DS-RPNIs reliably elicited CSNAPs at low current thresholds, and CSNAPs gradually increased in amplitude with increasing stimulation current. Conclusions: These findings suggest that afferent nerve fibers successfully reinnervate DS-RPNIs, and that graded stimuli applied to DS-RPNIs produce proximal sensory afferent responses similar to those evoked from normal skin. This confirmation of graded afferent signal transduction through DS-RPNI neural interfaces validate DS-RPNI's potential role of facilitating sensation in human-machine interfacing. Clinical Relevance Statement: The DS-RPNI is a novel biotic-abiotic neural interface that allows for transduction of sensory stimuli into neural signals. It is expected to advance the restoration of natural sensation and development of sensorimotor control in prosthetics.</p

    Regenerative peripheral nerve interfaces for real-time, proportional control of a Neuroprosthetic hand

    Full text link
    Abstract Introduction Regenerative peripheral nerve interfaces (RPNIs) are biological constructs which amplify neural signals and have shown long-term stability in rat models. Real-time control of a neuroprosthesis in rat models has not yet been demonstrated. The purpose of this study was to: a) design and validate a system for translating electromyography (EMG) signals from an RPNI in a rat model into real-time control of a neuroprosthetic hand, and; b) use the system to demonstrate RPNI proportional neuroprosthesis control. Methods Animals were randomly assigned to three experimental groups: (1) Control; (2) Denervated, and; (3) RPNI. In the RPNI group, the extensor digitorum longus (EDL) muscle was dissected free, denervated, transferred to the lateral thigh and neurotized with the residual end of the transected common peroneal nerve. Rats received tactile stimuli to the hind-limb via monofilaments, and electrodes were used to record EMG. Signals were filtered, rectified and integrated using a moving sample window. Processed EMG signals (iEMG) from RPNIs were validated against Control and Denervated group outputs. Results Voluntary reflexive rat movements produced signaling that activated the prosthesis in both the Control and RPNI groups, but produced no activation in the Denervated group. Signal-to-Noise ratio between hind-limb movement and resting iEMG was 3.55 for Controls and 3.81 for RPNIs. Both Control and RPNI groups exhibited a logarithmic iEMG increase with increased monofilament pressure, allowing graded prosthetic hand speed control (R2 = 0.758 and R2 = 0.802, respectively). Conclusion EMG signals were successfully acquired from RPNIs and translated into real-time neuroprosthetic control. Signal contamination from muscles adjacent to the RPNI was minimal. RPNI constructs provided reliable proportional prosthetic hand control.https://deepblue.lib.umich.edu/bitstream/2027.42/146521/1/12984_2018_Article_452.pd
    corecore