12 research outputs found

    Mouse neuroblastoma cell-based model and the effect of epileptic events on calcium oscillations and neural spikes

    Get PDF
    Recently, mouse neuroblastoma cells have been considered as an attractive model for the study of human neurological and prion diseases, and they have been intensively used as a model system in different areas. For example, the differentiation of neuro2a (N2A) cells, receptor-mediated ion current, and glutamate-induced physiological responses have been actively investigated with these cells. These mouse neuroblastoma N2A cells are of interest because they grow faster than other cells of neural origin and have a number of other advantages. The calcium oscillations and neural spikes of mouse neuroblastoma N2A cells in epileptic conditions are evaluated. Based on our observations of neural spikes in these cells with our proposed imaging modality, we reported that they can be an important model in epileptic activity studies. We concluded that mouse neuroblastoma N2A cells produce epileptic spikes in vitro in the same way as those produced by neurons or astrocytes. This evidence suggests that increased levels of neurotransmitter release due to the enhancement of free calcium from 4-aminopyridine causes the mouse neuroblastoma N2A cells to produce epileptic spikes and calcium oscillations.open0

    Ultra-Fast Displaying Spectral Domain Optical Doppler Tomography System Using a Graphics Processing Unit

    Get PDF
    We demonstrate an ultrafast displaying Spectral Domain Optical Doppler Tomography system using Graphics Processing Unit (GPU) computing. The calculation of FFT and the Doppler frequency shift is accelerated by the GPU. Our system can display processed OCT and ODT images simultaneously in real time at 120 fps for 1,024 pixels x 512 lateral A-scans. The computing time for the Doppler information was dependent on the size of the moving average window, but with a window size of 32 pixels the ODT computation time is only 8.3 ms, which is comparable to the data acquisition time. Also the phase noise decreases significantly with the window size. Since the performance of a real-time display for OCT/ODT is very important for clinical applications that need immediate diagnosis for screening or biopsy. Intraoperative surgery can take much benefit from the real-time display flow rate information from the technology. Moreover, the GPU is an attractive tool for clinical and commercial systems for functional OCT features as well.open131

    Optical Light Sources and Wavelengths within the Visible and Near-Infrared Range Using Photoacoustic Effects for Biomedical Applications

    No full text
    The photoacoustic (PA) effect occurs when sound waves are generated by light according to the thermodynamic and optical properties of the materials; they are absorption spectroscopic techniques that can be applied to characterize materials that absorb pulse or continuous wave (CW)-modulated electromagnetic radiation. In addition, the wavelengths and properties of the incident light significantly impact the signal-to-ratio and contrast with photoacoustic signals. In this paper, we reviewed how absorption spectroscopic research results have been used in applying actual photoacoustic effects, focusing on light sources of each wavelength. In addition, the characteristics and compositions of the light sources used for the applications were investigated and organized based on the absorption spectrum of the target materials. Therefore, we expect that this study will help researchers (who desire to study photoacoustic effects) to more efficiently approach the appropriate conditions or environments for selecting the target materials and light sources

    Photoacoustic imaging platforms for multimodal imaging

    Get PDF
    Photoacoustic (PA) imaging is a hybrid biomedical imaging method that exploits both acoustical Epub ahead of print and optical properties and can provide both functional and structural information. Therefore, PA imaging can complement other imaging methods, such as ultrasound imaging, fluorescence imaging, optical coherence tomography, and multi-photon microscopy. This article reviews techniques that integrate PA with the above imaging methods and describes their applications

    Simultaneous Measurement of Neural Spike Recordings and Multi-Photon Calcium Imaging in Neuroblastoma Cells

    Get PDF
    This paper proposes the design and implementation of a micro-electrode array (MEA) for neuroblastoma cell culturing. It also explains the implementation of a multi-photon microscope (MPM) customized for neuroblastoma cell excitation and imaging under ambient light. Electrical signal and fluorescence images were simultaneously acquired from the neuroblastoma cells on the MEA. MPM calcium images of the cultured neuroblastoma cell on the MEA are presented and also the neural activity was acquired through the MEA recording. A calcium green-1 (CG-1) dextran conjugate of 10,000 D molecular weight was used in this experiment for calcium imaging. This study also evaluated the calcium oscillations and neural spike recording of neuroblastoma cells in an epileptic condition. Based on our observation of neural spikes in neuroblastoma cells with our proposed imaging modality, we report that neuroblastoma cells can be an important model for epileptic activity studies

    Contrast-enhanced dual mode imaging: photoacoustic imaging plus more

    No full text
    Conventional biomedical imaging modalities inwide clinical use, such as ultrasound imaging, X-raycomputed tomography, magnetic resonance imaging, andpositron emission tomography, can provide morphological,anatomical, and functional information about biologicaltissues. However, single mode imaging in conventionalmedicine provides only limited information for definitivediagnoses. Thus, combinational diagnosis using multipleimaging modalities has become increasingly important. Recently, photoacoustic imaging (PAI) has gained significantattention, and several PAI prototypes have been usedin clinical trials. At the same time, PAI has been tested incombination with conventional imaging modalities. For allthese imaging modalities, various contrast-enhancingagents have been developed for various purposes. In thisreview article, we will focus on recent progress in developingdual mode contrast agents for PAI in combinationwith other conventional imaging modalities.111Nscopuskc

    Optical coherence tomography for the diagnosis of human otitis media

    No full text
    We report the application of Optical Coherence Tomography (OCT) to various types of human cases of otitis media (OM). Whereas conventional diagnostic modalities for OM, including standard and pneumatic otoscopy, are limited to visualizing the surface information of the tympanic membrane (TM), OCT is able to effectively reveal the depth-resolved microstructural below the TM with a very high spatial resolution. With the potential advantage of using OCT for diagnosing different types of OM, we examined in-vivo the use of 840 nm wavelength, and OCT spectral domain OCT (SDOCT) techniques, in several human cases including normal ears, and ears with adhesive and effusion types of OM. Peculiar positions were identified in two-dimensional OCT images of abnormal TMs compared to images of a normal TM. Analysis of A-scan (axial depth-scans) data from these positions could successfully identify unique patterns for different constituents within effusions. These OCT images may not only be used for constructing a database for the diagnosis and classification of OM, but they may also demonstrate the feasibility and advantages for upgrading the current otoscopy techniques

    High Speed SD-OCT System Using GPU Accelerated Mode for in vivo Human Eye Imaging

    No full text
    We developed an SD-OCT (Spectral Domain-Optical Coherence Tomography) system which uses a GPU (Graphics Processing Unit) for processing. The image size from the SD-OCT system is 1024 x 512 and the speed is 110 frame/sec in real-time. K-domain linearization, PET (Fast Fourier Transform), and log scaling were included in the GPU processing. The signal processing speed was about 62 ms using a CPU (Central Processing Unit) and 1.6 ms using a GPU, which is 39 times faster. We performed an in-vivo retinal scan, and reconstructed a 3D visualization based on C-scan images. As a result, there were minimal motion artifacts and we confirmed that tomograms of blood vessels, the optic nerve, and the optic disk are clearly identified. According to the results of this study, this SD-OCT can be applied to real-time 3D display technology, particularly auxiliary instruments for eye operations in ophthalmology.close4

    Numerical-Sampling-Functionalized Real-Time Index Regulation for Direct k-Domain Calibration in Spectral Domain Optical Coherence Tomography

    No full text
    An index-regulation technique functionalized by numerical sampling for direct calibration of the non-linear wavenumber (k)-domain to a linear domain in spectral domain optical coherence tomography (SD-OCT) is proposed. The objective of the developed method is to facilitate high-resolution identification of microstructures in biomedical imaging. Subjective optical alignments caused by nonlinear sampling of interferograms in the k-domain tend to hinder depth-dependent signal-to-noise ratios (SNR) and axial resolution in SD-OCT. Moreover, the optical-laser-dependent k-domain requires constant recalibrated in accordance with each laser transition, thereby necessitating either hardware or heavy software compensations. As the key feature of the proposed method, a relatively simple software-based k-domain mask calibration technique was developed to enable real-time linear sampling of k-domain interpolations whilst facilitating image observation through use of an index-regulation technique. Moreover, it has been confirmed that dispersion can be simultaneously compensated with noise residuals generated using the proposed technique, and that use of complex numerical or hardware techniques are no longer required. Observed results, such as fall-off, SNR, and axial resolution clearly exhibit the direct impact of the proposed technique, which could help investigators rapidly achieve optical-laser-independent high-quality SD-OCT images
    corecore