5 research outputs found
Dataset on FAP-induced emergence of spontaneous metastases and on the preparation of activatable FAP-targeting immunoliposomes to detect the metastases
The underlying data demonstrates that fibroblast activation protein (FAP) paves the way for fibrosarcoma cells, which require the proteolysis of the extracellular matrix (ECM) and basement membranes to intravasate from implanted subcutaneous primary tumors into blood vessels, be transported to distant organs where they extravasate from the blood vessels, reattach and proliferate to metastases. The data additionally shows that FAP, when overexpressed on fibrosarcoma cells induces their invasion and formation of spontaneous metastases in multiple organs, particularly after subcutaneous co-implantation of the FAP-expressing and wildtype fibrosarcoma. The raw and processed data presented herein is related to a research article entitled “Potential of activatable FAP-targeting immunoliposomes in intraoperative imaging of spontaneous metastases” (F.L. Tansi, R. Rüger, C. Böhm, R.E. Kontermann, U.K. Teichgraeber, A. Fahr, I. Hilger, 2016) [1]. Furthermore, evidence for the detection of FAP-expressing tumor cells and cells of the tumor stroma by activatable FAP-targeting liposomes is presented in this dataset
Dataset on the role of endoglin expression on melanin production in murine melanoma and on the influence of melanin on optical imaging
The underlying data demonstrates that the expression of endoglin in murine melanoma cells influences melanin production in the cells. Also, the data shows that melanin production is further increased when the cells are subcutaneously implanted in mice models and that the high melanin production prevents detection of the cells by fluorescence imaging. The processed data presented herein is related to a research article by Tansi et al. (2018) entitled “Endoglin based in vivo near-infrared fluorescence imaging of tumor models in mice using activatable liposomes”
Ultrashort echo time MRI of the lung in children and adolescents: comparison with non-enhanced computed tomography and standard post-contrast T1w MRI sequences
Objectives!#!To compare the diagnostic value of ultrashort echo time (UTE) magnetic resonance imaging (MRI) for the lung versus the gold standard computed tomography (CT) and two T1-weighted MRI sequences in children.!##!Methods!#!Twenty-three patients with proven oncologic disease (14 male, 9 female; mean age 9.0 + / - 5.4 years) received 35 low-dose CT and MRI examinations of the lung. The MRI protocol (1.5-T) included the following post-contrast sequences: two-dimensional (2D) incoherent gradient echo (GRE; acquisition with breath-hold), 3D volume interpolated GRE (breath-hold), and 3D high-resolution radial UTE sequences (performed during free-breathing). Images were evaluated by considering image quality as well as distinct diagnosis of pulmonary nodules and parenchymal areal opacities with consideration of sizes and characterisations.!##!Results!#!The UTE technique showed significantly higher overall image quality, better sharpness, and fewer artefacts than both other sequences. On CT, 110 pulmonary nodules with a mean diameter of 4.9 + / - 2.9 mm were detected. UTE imaging resulted in a significantly higher detection rate compared to both other sequences (p < 0.01): 76.4% (84 of 110 nodules) for UTE versus 60.9% (67 of 110) for incoherent GRE and 62.7% (69 of 110) for volume interpolated GRE sequences. The detection of parenchymal areal opacities by the UTE technique was also significantly higher with a rate of 93.3% (42 of 45 opacities) versus 77.8% (35 of 45) for 2D GRE and 80.0% (36 of 45) for 3D GRE sequences (p < 0.05).!##!Conclusion!#!The UTE technique for lung MRI is favourable in children with generally high diagnostic performance compared to standard T1-weighted sequences as well as CT. Key Points • Due to the possible acquisition during free-breathing of the patients, the UTE MRI sequence for the lung is favourable in children. • The UTE technique reaches higher overall image quality, better sharpness, and lower artefacts, but not higher contrast compared to standard post-contrast T1-weighted sequences. • In comparison to the gold standard chest CT, the detection rate of small pulmonary nodules small nodules ≤ 4 mm and subtle parenchymal areal opacities is higher with the UTE imaging than standard T1-weighted sequences