480 research outputs found
Design and Tests of the Silicon Sensors for the ZEUS Micro Vertex Detector
To fully exploit the HERA-II upgrade,the ZEUS experiment has installed a
Micro Vertex Detector (MVD) using n-type, single-sided, silicon micro-strip
sensors with capacitive charge division. The sensors have a readout pitch of
120 micrometers, with five intermediate strips (20 micrometer strip pitch). The
designs of the silicon sensors and of the test structures used to verify the
technological parameters, are presented. Results on the electrical measurements
are discussed. A total of 1123 sensors with three different geometries have
been produced by Hamamatsu Photonics K.K. Irradiation tests with reactor
neutrons and Co-60 photons have been performed for a small sample of sensors.
The results on neutron irradiation (with a fluence of 1 x 10^{13} 1 MeV
equivalent neutrons / cm^2) are well described by empirical formulae for bulk
damage. The Co-60 photons (with doses up to 2.9 kGy) show the presence of
generation currents in the SiO_2-Si interface, a large shift of the flatband
voltage and a decrease of the hole mobility.Comment: 33 pages, 25 figures, 3 tables, accepted for publication in NIM
Aspects of Axion Phenomenology in a slice of AdS_5
Motivated by multi-throat considerations, we study the phenomenological
implications of a bulk axion in a slice of AdS_5 with a large extra dimension:
k~0.01 eV, kR > 1. In particular, we compare axion physics with a warped
geometry to axions in flat compactifications. As in flat compactification
scenarios, we find that the mass of the axion can become independent from the
underlying Peccei-Quinn scale. Surprisingly, we find that in warped extra
dimensions the axion's invisibility, cosmological viability, and basic
phenomenology remain essentially unaltered in comparison to axions in flat
compactifications.Comment: 25 pages, 9 figure
SCTA - A Rad-Hard BiCMOS Analogue Readout ASIC for the ATLAS Semiconductor Tracker
Two prototype chips for the analogue readout of silicon strip detectors in the ATLAS Semiconductor Tracker (SCT) have been designed and manufactured, in 32 channels and 128 channel versions, using the radiation hard BiCMOS DMILL process. The SCTA chip comprises three basic blocks: front-end amplifier, analogue pipeline and output multiplexer. The front-end circuit is a fast transresistance amplifier followed by an integrator, providing fast shaping with a peaking time of 25 ns, and an output buffer. The front end output values are sampled at 40 MHz rate and stored in a 112-cell deep analogue pipeline. The delay between the write pointer and trigger pointer is tunable between 2 ms and 2.5 ms. The chip has been tested successfully and subsequently irradiated up to 10 Mrad. Full functionality of all blocks of the chip has been achieved at a clock frequency of 40 MHz both before and after irradiation. Noise figures of ENC = 720 e- + 33 e-/pF before irradiation and 840 e- + 33 e-/pF after irradiation have been obtained
Beam Test of Silicon Strip Sensors for the ZEUS Micro Vertex Detector
For the HERA upgrade, the ZEUS experiment has designed and installed a high
precision Micro Vertex Detector (MVD) using single sided micro-strip sensors
with capacitive charge division. The sensors have a readout pitch of 120
microns, with five intermediate strips (20 micron strip pitch). An extensive
test program has been carried out at the DESY-II testbeam facility. In this
paper we describe the setup developed to test the ZEUS MVD sensors and the
results obtained on both irradiated and non-irradiated single sided micro-strip
detectors with rectangular and trapezoidal geometries. The performances of the
sensors coupled to the readout electronics (HELIX chip, version 2.2) have been
studied in detail, achieving a good description by a Monte Carlo simulation.
Measurements of the position resolution as a function of the angle of incidence
are presented, focusing in particular on the comparison between standard and
newly developed reconstruction algorithms.Comment: 41 pages, 21 figures, 2 tables, accepted for publication in NIM
The Presampler for the Forward and Rear Calorimeter in the ZEUS Detector
The ZEUS detector at HERA has been supplemented with a presampler detector in
front of the forward and rear calorimeters. It consists of a segmented
scintillator array read out with wavelength-shifting fibers. We discuss its
desi gn, construction and performance. Test beam data obtained with a prototype
presampler and the ZEUS prototype calorimeter demonstrate the main function of
this detector, i.e. the correction for the energy lost by an electron
interacting in inactive material in front of the calorimeter.Comment: 20 pages including 16 figure
Limits on the effective quark radius from inclusive scattering at HERA
The high-precision HERA data allows searches up to TeV scales for Beyond the
Standard Model contributions to electron-quark scattering. Combined
measurements of the inclusive deep inelastic cross sections in neutral and
charged current scattering corresponding to a luminosity of around 1
fb have been used in this analysis. A new approach to the beyond the
Standard Model analysis of the inclusive data is presented; simultaneous
fits of parton distribution functions together with contributions of "new
physics" processes were performed. Results are presented considering a finite
radius of quarks within the quark form-factor model. The resulting 95% C.L.
upper limit on the effective quark radius is cm.Comment: 10 pages, 4 figures, accepted by Phys. Lett.
Measurement of the cross-section ratio sigma_{psi(2S)}/sigma_{J/psi(1S)} in deep inelastic exclusive ep scattering at HERA
The exclusive deep inelastic electroproduction of and
at an centre-of-mass energy of 317 GeV has been studied with the ZEUS
detector at HERA in the kinematic range GeV,
GeV and GeV, where is the photon virtuality, is the
photon-proton centre-of-mass energy and is the squared four-momentum
transfer at the proton vertex. The data for GeV were taken in
the HERA I running period and correspond to an integrated luminosity of 114
pb. The data for GeV are from both HERA I and HERA II
periods and correspond to an integrated luminosity of 468 pb. The decay
modes analysed were and for the
and for the . The cross-section ratio
has been measured as a function of
and . The results are compared to predictions of QCD-inspired
models of exclusive vector-meson production.Comment: 24 pages, 8 figure
The small angle rear tracking detector of ZEUS
Abstract The design, construction, installation, and performance of the small angle rear tracking detector of the ZEUS experiment are described. The results on electron position measurement, electron energy correction, and background reduction at the first-level trigger are presented. The impact on the measurement of the proton structure function is discussed
- …