1,047 research outputs found
A novel case of MSTO1 gene related congenital muscular dystrophy with progressive neurological involvement
Recessive mutations in the MSTO1 gene, encoding for a mitochondrial distribution and morphology regulator, have been recently described in a very limited number of patients with multisystem involvement, mostly characterized by myopathy or dystrophy, cerebellar ataxia, pigmentary retinopathy and raised creatine kinase levels. Here we report an additional patient with recessive MSTO1-related muscular dystrophy (MSTO1-RD), and clinical and radiological evidence of progressive cerebellar involvement. Whole-exome sequencing identified two novel MSTO1 missense variants, c.766C > T (p. (Arg256Trp) and c.1435C > T (p. (Pro479Ser), predicted as damaging by in silico tools. We also report a distinct pattern of selective involvement on muscle MRI in MSTO1-RD. This case confirms a consistent MSTO1-related neuromuscular phenotype and in addition suggests a progressive neurological component at least in some patients, in keeping with the mitochondrial role of the defective protein
Hypofractionated radiotherapy for prostate cancer
In the last few years, hypofractionated external beam radiotherapy has gained increasing popularity for prostate cancer treatment, since sufficient evidence exists that prostate cancer has a low alpha/beta ratio, lower than the one of the surrounding organs at risk and thus there is a potential therapeutic benefit of using larger fractionated single doses. Apart from the therapeutic rationale there are advantages such as saving treatment time and medical resources and thereby improving patient's convenience. While older trials showed unsatisfactory results in both standard and hypofractionated arm due to insufficient radiation doses and non-standard contouring of target volumes, contemporary randomized studies have reported on encouraging results of tumor control mostly without an increase of relevant side effects, especially late toxicity. Aim of this review is to give a detailed analysis of relevant, recently published clinical trials with special focus on rationale for hypofractionation and different therapy settings
Diagnostic accuracy of contrast-enhanced MR angiography in severe carotid stenosis: meta-analysis with metaregression of different techniques
Contrast-enhanced magnetic resonance angiography (CE-MRA) has become a well-established noninvasive imaging method for the assessment of severe carotid stenosis (70–99% by NASCET criteria). However, CE-MRA is not a standardised technique, but encompasses different concurrent techniques. This review analyses possible differences. A bivariate random effects meta-analysis of 17 primary diagnostic accuracy studies confirmed a high pooled sensitivity of 94.3% and specificity of 93.0% for carotid CE-MRA in severe carotid stenosis. Sensitivity was fairly uniform among the studies, while specificity showed significant variation (I2 = 73%). Metaregressions found significant differences for specificity with two covariates: specificity was higher when using not only maximum intensity projection (MIP) images, but also three-dimensional (3D) images (P = 0.01). Specificity was also higher with electronic images than with hardcopies (P = 0.02). The timing technique (bolus-timed, fluoroscopically triggered or time-resolved) did not result in any significant differences in diagnostic accuracy. Some nonsignificant trends were found for the percentages of severe carotid disease, acquisition time and voxel size. In conclusion, in CE-MRA of severe carotid stenosis the three major timing techniques yield comparably high diagnostic accuracy, electronic images are more specific than hardcopies, and 3D images should be used in addition to MIP images to increase the specificity
Resisting the mantle of the monstrous feminine : women's construction and experience of premenstrual embodiment
The female reproductive body is positioned as abject, as other, as site of defciency and disease, the epitome of the ‘monstrous feminine.’ Premenstrual change in emotion, behavior or embodied sensation is positioned as a sign of madness within, necessitating restraint and control on the part of the women experiencing it (Ussher 2006). Breakdown in this control through manifestation of ‘symptoms’ is diagnosed as PMS (Premenstrual Syndrome) or PMDD (Premenstrual Dysphoric Disorder), a pathology deserving of ‘treatment.’ In this chapter, we adopt a feminist material-discursive theoretical framework to examine the role of premenstrual embodiment in relation to women’s adoption of the subject position of monstrous feminine, drawing on interviews we have conducted with women who self-diagnose as ‘PMS sufferers.’ We theorize women’s self-positioning as subjectifcation, wherein women take up cultural discourse associated with idealized femininity and the reproductive body, resulting in self-objectifcation, distress, and self-condemnation. However, women can resist negative cultural constructions of premenstrual embodiment and the subsequent self-policing. We describe the impact of women-centered psychological therapy which increases awareness of embodied change, and leads to greater acceptance of the premenstrual body and greater self-care, which serves to reduce premenstrual distress
Evidence for an excess of B -> D(*) Tau Nu decays
Based on the full BaBar data sample, we report improved measurements of the
ratios R(D(*)) = B(B -> D(*) Tau Nu)/B(B -> D(*) l Nu), where l is either e or
mu. These ratios are sensitive to new physics contributions in the form of a
charged Higgs boson. We measure R(D) = 0.440 +- 0.058 +- 0.042 and R(D*) =
0.332 +- 0.024 +- 0.018, which exceed the Standard Model expectations by 2.0
sigma and 2.7 sigma, respectively. Taken together, our results disagree with
these expectations at the 3.4 sigma level. This excess cannot be explained by a
charged Higgs boson in the type II two-Higgs-doublet model. We also report the
observation of the decay B -> D Tau Nu, with a significance of 6.8 sigma.Comment: Expanded section on systematics, text corrections, improved the
format of Figure 2 and included the effect of the change of the Tau
polarization due to the charged Higg
Observation and study of baryonic B decays: B -> D(*) p pbar, D(*) p pbar pi, and D(*) p pbar pi pi
We present a study of ten B-meson decays to a D(*), a proton-antiproton pair,
and a system of up to two pions using BaBar's data set of 455x10^6 BBbar pairs.
Four of the modes (B0bar -> D0 p anti-p, B0bar -> D*0 p anti-p, B0bar -> D+ p
anti-p pi-, B0bar -> D*+ p anti-p pi-) are studied with improved statistics
compared to previous measurements; six of the modes (B- -> D0 p anti-p pi-, B-
-> D*0 p anti-p pi-, B0bar -> D0 p anti-p pi- pi+, B0bar -> D*0 p anti-p pi-
pi+, B- -> D+ p anti-p pi- pi-, B- -> D*+ p anti-p pi- pi-) are first
observations. The branching fractions for 3- and 5-body decays are suppressed
compared to 4-body decays. Kinematic distributions for 3-body decays show
non-overlapping threshold enhancements in m(p anti-p) and m(D(*)0 p) in the
Dalitz plots. For 4-body decays, m(p pi-) mass projections show a narrow peak
with mass and full width of (1497.4 +- 3.0 +- 0.9) MeV/c2, and (47 +- 12 +- 4)
MeV/c2, respectively, where the first (second) errors are statistical
(systematic). For 5-body decays, mass projections are similar to phase space
expectations. All results are preliminary.Comment: 28 pages, 90 postscript figures, submitted to LP0
Search for the decay modes D^0 → e^+e^-, D^0 → μ^+μ^-, and D^0 → e^±μ∓
We present searches for the rare decay modes D^0→e^+e^-, D^0→μ^+μ^-, and D^0→e^±μ^∓ in continuum e^+e^-→cc events recorded by the BABAR detector in a data sample that corresponds to an integrated luminosity of 468  fb^(-1). These decays are highly Glashow–Iliopoulos–Maiani suppressed but may be enhanced in several extensions of the standard model. Our observed event yields are consistent with the expected backgrounds. An excess is seen in the D^0→μ^+μ^- channel, although the observed yield is consistent with an upward background fluctuation at the 5% level. Using the Feldman–Cousins method, we set the following 90% confidence level intervals on the branching fractions: B(D^0→e^+e^-)<1.7×10^(-7), B(D^0→μ^+μ^-) within [0.6,8.1]×10^(-7), and B(D^0→e^±μ^∓)<3.3×10^(-7)
Patient Acceptance of Noninvasive and Invasive Coronary Angiography
BACKGROUND: Noninvasive angiography using multislice computed tomography (MSCT) is superior to magnetic resonance imaging (MRI) for detection of coronary stenoses. We compared patient acceptance of these two noninvasive diagnostic tests and invasive conventional coronary angiography (Angio). METHODS AND FINDINGS: A total of 111 consecutive patients with suspected coronary artery disease underwent MSCT, MRI, and Angio. Subsequently, patient acceptance of the three tests was evaluated with questionnaires in all patients. The main acceptance variables were preparation and information prior to the test, degree of concern, comfort, degree of helplessness, pain (on visual analog scales), willingness to undergo the test again, and overall satisfaction. Preparation for each test was not rated significantly differently, whereas patients were significantly more concerned about Angio than the two noninvasive tests (p<0.001). No pain during MSCT, MRI, and Angio as assessed on visual analog scales (0 to 100) was reported by 99, 93, and 31 patients, respectively. Among the 82 patients who felt pain during at least one procedure, both CT (0.9±4.5) and MRI (5.2±16.6) were significantly less painful than Angio (24.6±23.4, both p<0.001). MSCT was considered significantly more comfortable (1.49±0.64) than MRI (1.75±0.81, p<0.001). In both the no-revascularization (55 patients) and the revascularization group (56 patients), the majority of the patients (73 and 71%) would prefer MSCT to MRI and Angio for future imaging of the coronary arteries. None of the patients indicated to be unwilling to undergo MSCT again. The major advantages patients attributed to MSCT were its fast, uncomplicated, noninvasive, and painless nature. CONCLUSIONS: Noninvasive coronary angiography with MSCT is considered more comfortable than MRI and both MSCT and MRI are less painful than Angio. Patient preference for MSCT might tip the scales in favor of this test provided that the diagnostic accuracy of MSCT can be shown to be high enough for clinical application
A search for the decay modes B+/- to h+/- tau l
We present a search for the lepton flavor violating decay modes B+/- to h+/-
tau l (h= K,pi; l= e,mu) using the BaBar data sample, which corresponds to 472
million BBbar pairs. The search uses events where one B meson is fully
reconstructed in one of several hadronic final states. Using the momenta of the
reconstructed B, h, and l candidates, we are able to fully determine the tau
four-momentum. The resulting tau candidate mass is our main discriminant
against combinatorial background. We see no evidence for B+/- to h+/- tau l
decays and set a 90% confidence level upper limit on each branching fraction at
the level of a few times 10^-5.Comment: 15 pages, 7 figures, submitted to Phys. Rev.
- …