    Rapid MR elastography of the liver for subsecond stiffness sampling

    Get PDF
    PURPOSE: Depicting the stiffness of biological soft tissues, MR elastography (MRE) has a wide range of diagnostic applications. The purpose of this study was to improve the temporal resolution of 2D hepatic MRE in order to provide more rapid feedback on the quality of the wavefield and ensure better temporal sampling of respiration-induced stiffness changes. METHODS: We developed a rapid MRE sequence that uses 2D segmented gradient-echo spiral readout to encode 40 Hz harmonic vibrations and generate stiffness maps within 625 ms. We demonstrate the use of this technique as a rapid test for shear wave amplitudes and overall MRE image quality and as a method for monitoring respiration-induced stiffness changes in the liver in comparison to 3D MRE and ultrasound-based time-harmonic elastography. RESULTS: Subsecond MRE allowed monitoring of increasing shear wave amplitudes in the liver with increasing levels of external stimulation within a single breath-hold. Furthermore, the technique detected respiration-induced changes in liver stiffness with peak values (1.83 ± 0.22 m/s) at end-inspiration, followed by softer values during forced abdominal pressure (1.60 ± 0.22 m/s) and end-expiration (1.49 ± 0.22 m/s). The effects of inspiration and expiration were confirmed by time-harmonic elastography. CONCLUSION: Our results suggest that subsecond MRE of the liver is useful for checking MRE driver settings and monitoring breathing-induced changes in liver stiffness in near real time

    Vibration-synchronized magnetic resonance imaging for the detection of myocardial elasticity changes

    No full text
    Vibration synchronized magnetic resonance imaging of harmonically oscillating tissue interfaces is proposed for cardiac magnetic resonance elastography. The new approach exploits cardiac triggered cine imaging synchronized with extrinsic harmonic stimulation (f = 22.83 Hz) to display oscillatory tissue deformations in magnitude images. Oscillations are analyzed by intensity threshold-based image processing to track wave amplitude variations over the cardiac cycle. In agreement to literature data, results in 10 volunteers showed that endocardial wave amplitudes during systole (0.13 ± 0.07 mm) were significantly lower than during diastole (0.34 ± 0.14 mm, P < 0.001). Wave amplitudes were found to decrease 117 ± 40 ms before myocardial contraction and to increase 75 ± 31 ms before myocardial relaxation. Vibration synchronized magnetic resonance imaging improves the temporal resolution of magnetic resonance elastography as it overcomes the use of extra motion encoding gradients, is less sensitive to susceptibility artifacts, and does not suffer from dynamic range constraints frequently encountered in phase-based magnetic resonance elastography
    corecore