56 research outputs found

    Steady state of atoms in a resonant field with elliptical polarization

    Full text link
    We present a complete set of analytical and invariant expressions for the steady-state density matrix of atoms in a resonant radiation field with arbitrary intensity and polarization. The field drives the closed dipole transition with arbitrary values of the angular momenta JgJ_{g} and JeJ_{e} of the ground and excited state. The steady-state density matrix is expressed in terms of spherical harmonics of a complex direction given by the field polarization vector. The generalization to the case of broad-band radiation is given. We indicate various applications of these results.Comment: revtex, 26 pages, including 3 eps figures; PRA accepted for publication;v2 three typos are fixe

    Dissipative light field as a way to create strongly localized structures for atom lithography

    Get PDF
    Generally, the conditions for deep sub-Doppler laser cooling do not match the conditions for the strong atomic localization that takes a place in deeper optical potential and, in consequence, leads to larger temperature. Moreover, for a given detuning in a deep optical potential the secular approximation which is usually used for quantum description of laser cooling becomes no more valid. Here we perform an analysis of atomic localization in optical potential based on a full quantum approach for atomic density matrix. We also show that the laser cooling in a deep far-off detuned optical potential, created by a light field with a polarization gradient, can be used as an alternative method for forming high contrast spatially localized structures of atoms for the purposes of atom lithography and atomic nanofabrication. Finally, we perform an analysis of the possible limits for the width and the contrast of localized atomic structures that can in principle be reached by this type of the light mask.Comment: 4 figure

    Microwave Spectroscopy of Cold Rubidium Atoms

    Full text link
    The effect of microwave radiation on the resonance fluorescence of a cloud of cold 85Rb^{85}Rb atoms in a magnetooptical trap is studied. The radiation frequency was tuned near the hyperfine splitting frequency of rubidium atoms in the 5S ground state. The microwave field induced magnetic dipole transitions between the magnetic sublevels of the 5S(F=2) and 5S(F=3) states, resulting in a change in the fluorescence signal. The resonance fluorescence spectra were recorded by tuning the microwave radiation frequency. The observed spectra were found to be substantially dependent on the transition under study and the frequency of a repump laser used in the cooling scheme.Comment: 6 pages, 4 figure

    Measurement of J/ψγηcJ/\psi\to\gamma\eta_{\rm c} decay rate and ηc\eta_{\rm c} parameters at KEDR

    Full text link
    Using the inclusive photon spectrum based on a data sample collected at the J/ψJ/\psi peak with the KEDR detector at the VEPP-4M e+ee^+e^- collider, we measured the rate of the radiative decay J/ψγηcJ/\psi\to\gamma\eta_{\rm c} as well as ηc\eta_{\rm c} mass and width. Taking into account an asymmetric photon lineshape we obtained Γγηc0=2.98±0.180.33+0.15\Gamma^0_{\gamma\eta_{\rm c}}=2.98\pm0.18 \phantom{|}^{+0.15}_{-0.33} keV, Mηc=2983.5±1.43.6+1.6M_{\eta_{\rm c}} = 2983.5 \pm 1.4 \phantom{|}^{+1.6}_{-3.6} MeV/c2c^2, Γηc=27.2±3.12.6+5.4\Gamma_{\eta_{\rm c}} = 27.2 \pm 3.1 \phantom{|}^{+5.4}_{-2.6} MeV.Comment: 6 pages, 3 figure

    Precise measurement of RudsR_{\text{uds}} and RR between 1.84 and 3.72 GeV at the KEDR detector

    Full text link
    The present work continues a series of the KEDR measurements of the RR value that started in 2010 at the VEPP-4M e+ee^+e^- collider. By combining new data with our previous results in this energy range we measured the values of RudsR_{\text{uds}} and RR at nine center-of-mass energies between 3.08 and 3.72 GeV. The total accuracy is about or better than 2.6%2.6\% at most of energy points with a systematic uncertainty of about 1.9%1.9\%. Together with the previous precise RR measurement at KEDR in the energy range 1.84-3.05 GeV, it constitutes the most detailed high-precision RR measurement near the charmonium production threshold.Comment: arXiv admin note: text overlap with arXiv:1610.02827 and substantial text overlap with arXiv:1510.0266

    Measurement of J/psi to eta_c gamma at KEDR

    Full text link
    We present a study of the inclusive photon spectra from 5.9 million J/psi decays collected with the KEDR detector at the VEPP-4M e+e- collider. We measure the branching fraction of radiative decay J/psi to eta_c gamma, eta_c width and mass. Our preliminary results are: M(eta_c) = 2979.4+-1.5+-1.9 MeV, G(eta_c) = 27.8+-5.1+-3.3 MeV, B(J/psi to eta_c gamma) = (2.34+-0.15+-0.40)%.Comment: To be published in Proceedings of the PhiPsi09, Oct. 13-16, 2009, Beijing, Chin

    Measurement of B(J/psi->eta_c gamma) at KEDR

    Full text link
    We present a study of the inclusive photon spectrum from 6.3 million J/psi decays collected with the KEDR detector at the VEPP-4M e+e- collider. We measure the branching fraction of the radiative decay J/psi -> eta_c gamma, eta_c width and mass. Taking into account an asymmetric photon line shape we obtain: M(eta_c) = (2978.1 +- 1.4 +- 2.0) MeV/c^2, Gamma(eta_c) = (43.5 +- 5.4 +- 15.8) MeV, B(J/psi->eta_c gamma) = (2.59 +- 0.16 +- 0.31)%$.Comment: 6 pages, 1 figure. To be published in the proceedings of the 4th International Workshop on Charm Physics (Charm2010), October 21-24, 2010, IHEP, Beijin
    corecore