4 research outputs found

    Short-Term Variability of the QT Interval Can be Used for the Prediction of Imminent Ventricular Arrhythmias in Patients With Primary Prophylactic Implantable Cardioverter Defibrillators

    Get PDF
    Background Short-term variability of the QT interval (STVQT) has been proposed as a novel electrophysiological marker for the prediction of imminent ventricular arrhythmias in animal models. Our aim is to study whether STVQT can predict imminent ventricular arrhythmias in patients. Methods and Results In 2331 patients with primary prophylactic implantable cardioverter defibrillators, 24-hour ECG Holter recordings were obtained as part of the EU-CERT-ICD (European Comparative Effectiveness Research to Assess the Use of Primary Prophylactic Implantable Cardioverter Defibrillators) study. ECG Holter recordings showing ventricular arrhythmias of >4 consecutive complexes were selected for the arrhythmic groups (n=170), whereas a control group was randomly selected from the remaining Holter recordings (n=37). STVQT was determined from 31 beats with fiducial segment averaging and calculated as [Formula: see text], where Dn represents the QT interval. STVQT was determined before the ventricular arrhythmia or 8:00 am in the control group and between 1:30 and 4:30 am as baseline. STVQT at baseline was 0.84±0.47 ms and increased to 1.18±0.74 ms (P<0.05) before the ventricular arrhythmia, whereas the STVQT in the control group remained unchanged. The arrhythmic patients were divided into three groups based on the severity of the arrhythmia: (1) nonsustained ventricular arrhythmia (n=32), (2) nonsustained ventricular tachycardia (n=134), (3) sustained ventricular tachycardia (n=4). STVQT increased before nonsustained ve

    Multimodality imaging for real-time image-guided left ventricular lead placement during cardiac resynchronization therapy implantations

    No full text
    This study was performed to evaluate the feasibility of intra-procedural visualization of optimal pacing sites and image-guided left ventricular (LV) lead placement in cardiac resynchronization therapy (CRT). In fifteen patients (10 males, 68 ± 11 years, 7 with ischemic cardiomyopathy and ejection fraction of 26 ± 5%), optimal pacing sites were identified pre-procedurally using cardiac imaging. Cardiac magnetic resonance (CMR) derived scar and dyssynchrony maps were created for all patients. In six patients the anatomy of the left phrenic nerve (LPN) and coronary sinus ostium was assessed via a computed tomography (CT) scan. By overlaying the CMR and CT dataset onto live fluoroscopy, aforementioned structures were visualized during LV lead implantation. In the first nine patients, the platform was tested, yet, no real-time image-guidance was implemented. In the last six patients real-time image-guided LV lead placement was successfully executed. CRT implant and fluoroscopy times were similar to previous procedures and all leads were placed close to the target area but away from scarred myocardium and the LPN. Patients that received real-time image-guided LV lead implantation were paced closer to the target area compared to patients that did not receive real-time image-guidance (8 mm [IQR 0–22] vs 26 mm [IQR 17–46], p = 0.04), and displayed marked LV reverse remodeling at 6 months follow up with a mean LVESV change of −30 ± 10% and a mean LVEF improvement of 15 ± 5%. Real-time image-guided LV lead implantation is feasible and may prove useful for achieving the optimal LV lead position

    Elektrophysiologie und Pathophysiologie von Vorhofflimmern

    No full text
    corecore