11 research outputs found
Ultrahigh birefringence index-guiding photonic crystal fiber and its application for pressure and temperature discrimination
2012-2013 > Academic research: refereed > Publication in refereed journalVersion of RecordPublishe
Amplified spontaneous emission of side-pumped step-index Rh640 perchlorate-dye-doped polymer optical fiber
Workshop on Specialty Optical Fibers and their Applications, WSOF 2013, Sigtuna, 28-30 August 20132013-2014 > Academic research: refereed > Refereed conference paperVersion of RecordPublishe
Optimization of 3-hole-assisted PMMA optical fiber with double cladding for UV-induced FBG fabrication
Author name used in this publication: Ming-Leung Vincent TseAuthor name used in this publication: C. LuAuthor name used in this publication: P. K. A. Wai2008-2009 > Academic research: refereed > Publication in refereed journalVersion of RecordPublishe
High pressure sensor based on photonic crystal fiber for downhole application
Author name used in this publication: H. Y. Tam2009-2010 > Academic research: refereed > Publication in refereed journalVersion of RecordPublishe
Observation of symmetrical reflection sidebands in a silica suspended-core fiber Bragg grating
Author name used in this publication: K. C. D. ChengAuthor name used in this publication: C. LuAuthor name used in this publication: H. Y. Tam2010-2011 > Academic research: refereed > Publication in refereed journalVersion of RecordPublishe
Reliability of PMMA-based FBG for humidity sensing
Integrated Photonics Research, Silicon and Nanophotonics, IPRSN 2016, Vancouver, 18–20 July 2016202309 bcwhVersion of RecordSelf-fundedPublishe
Superlattice microstructured optical fiber
2013-2014 > Academic research: refereed > Publication in refereed journalVersion of RecordPublishe
In-line microfluidic refractometer based on C-shaped fiber assisted photonic crystal fiber Sagnac interferometer
We propose and demonstrate a highly sensitive in-line photonic crystal fiber (PCF) microfluidic refractometer. Ultrathin C-shaped fibers are spliced in-between the PCF and standard single-mode fibers. The C-shaped fibers provide openings for liquid to flow in and out of the PCF. Based on a Sagnac interferometer, the refractive index (RI) response of the device is investigated theoretically and experimentally. A high sensitivity of 6621 nm/RIU for liquid RI from 1.330 to 1.333 is achieved in the experiment, which agrees well with the theoretical analysis.Department of Electrical EngineeringDepartment of Electronic and Information Engineerin
Ultra-fast polymer optical fibre Bragg grating inscription for medical devices
201812 bcrcVersion of RecordPublishe
Fiber optic pressure sensor based on polarization-maintaining photonic crystal fiber for downhole application
20th International Conference on Optical Fibre Sensors, Edinburgh, 5-9 October 2009We experimentally demonstrate a high pressure sensor based on a polarization-maintaining photonic crystal fiber (PMPCF) with Sagnac loop configuration for downhole application. The pressure sensitivity of the proposed sensor is 4.21 nm/MPa and 3.27 nm/MPa at ∼1320 nm and ∼1550 nm respectively. High pressure measurement up to 20 MPa has been achieved in our experiment. The sensor also shows reduced temperature sensitivity, making it an ideal candidate for pressure sensing in harsh environment.Department of Electrical EngineeringDepartment of Electronic and Information Engineerin